Electron tubes for TV and radio broadcast

publicité
Po wer-grid tubes
Power-grid tubes
f o r r a d i o & TV
Thomson power-grid tubes
Index of Thomson power-grid tubes and cavities
Tube selection guide by band and power output
Replacement tubes and cavities
Tube and cavity data sheets
Tube dimensions
Quality performances of tetrode technologies
High-power tetrode technology
Thoriated-tungsten cathodes
Grids
Grid design considerations
The classical solution
The useful properties of ~ ~ r o b l o grids
d@
Manufacturing Pyrobloc grids
Anodes
Forced-air cooling
Hypervapotron cooling
Ceramic insulators
Power-grid tube performances in transmitters
Radio transmitters
63
63
TV transmitters
Amplification mode
Gain
1,\ M O M S O N
1
TUBES ELECTRONIQUES
-- -
-
Power-grid tubes
I
I
Thomson Tubes Electroniques' RF-circuit assemblies
65
65
RF-circuit connectors
TV-transmitter circuits
Coupled c~rcu~ts
Mechancal s ~ m p l ~ cand
~ t y standardizabon
Matenals and technology
Development and product~on
1
Operating information and recommendations
Transportation, handling and storage
I
I
1
I
I
Entering a tube into service
Tube ~nstallat~on
F~rstuse of a new tube
Voltage appi~cabonand settings
Cavlty tun~ngaffer removal/ ~nstallabon
Trançmitter design considerations
Cathodes
Hea ter voltage
Regulation
Application and shutdown of heater voltage
Grids
Anodes
Cooling
Hypervapotron cooling
Forced-air cooling
Air cooling and transmitter site
Selection of a suitable cooling fan
Basic principles of power-grid tubes
The basic diode
Triodes
Basic mechanisms
Characterist~ccurves
Parameters character~z~ng
tr~odeoperation
Tetrodes
Basic mechanisms
Characteristic curves
1,\ THOMSON TUBES ELECTRONIQUES
"
%
Power-grid tubes
Power-grid tubes
for radio & TV broadcasting
G
reater attention to the cost competivity of radio or TV stations has made
cost-of-ownership of the broadcasting transrnifter a vital concern. Of the
many competing technologies for the power amplifier. modern high-power
tetrodes provide an ideal solution. New developments in tube capabilities have led
to higher efficiencies, longer lifetimes, and increased cost effectiveness. Combined
with their high reliability and the simplicity of amplifier design, tetrode transmiff ers
also offer a larger bandwidth for future broadcasting techniques.
Thomson Tubes Electroniques has been at the forefront of power-grid tube
technology over many years. The company pioneered such developments as
~ ~ r o b l o cgrids
"
and ~ ~ ~ e r v a ~ ocoollng,
t r o nand
~ ~more recently that of the
high-power UHF tetrode.
Thls techn~caledge is the result of the company's cont~nuedR& D investmenf ln
gnd-tube technology. It also stems from a mot~vatedworkforce and rts hrghly
qualrfied engineers and technlcians TheIr v~tal~ty
has allowed the electron-tube
industry to offer the best solut~onsfor today's and tomorrow's transmitters. The use
of advanced analyttcal and computing tools as well as our modern product~on
techniques has ensured that our extensive product range has kept Pace with
evolving needs.
The Power-Grid Tube Division of Thomson Tubes Electroniques is located at
Thonon, overlooking Lake Geneva in the French Alps. The company's headquarters
in the south-west of Pan's are home to the Sales and Marketing Teams. They are
part of a worldwide customer support network dedicated to assisting you in correct
tube choice, and ensuring you get the most from your Thomson tube.
Thomson is also a leading player in more recent transmission techniques such as
satellite news gathering and direct broadcasf satellites. The company's space
traveling-wave tubes (TWTs) have been chosen for the latest broadcasting satellites
including USDBS, Hispasat and Telecom 1 & 2. On the ground, Thomson3 TWTs
and klystrons provide the performances required for video transmissions via earth
stations and mobile uplinks.
Thomson Tubes Electroniques is also engaged in the development of HDTV. The
company offers high-definition projection CRTs for large-screen displays, bringing in
the era of the electronic cinema.
Furthermore, tetrodes provide the enhanced performances compatible with UHF
HDTV transmission. Thomson Tubes Electroniques' long-term commitment to the
radio and TV industry has made such technological progress possible. lt also
guarantees the ongoing availability of our product line.
Whatever your projects in radio or TV, you should be gaining from Thomson Tubes
Electroniques, the leading edge in electron tubes.
3
Power-grid tubes
Index
Thomson power-grid tubes and cavities
Reference
-TH 225
TH 287
TH 289
-
Band
Power T y
250 W
10 kW
2kW
Power is indicated as
carrier power for rad10
tubes and peak-of-sync
video for TV transm!tter
TH 376
5 kW
p
e Cooling
Page
VHF
VHF
Radio
FM
UHF
Tetrode
Triode
Tetrode
Tetrode
Tetrode
air
air
air
air
air
12
8
8
8
8
UHF
UHF
VHF
UHF
UHF
Tetrode
Triode
Tetrode
Triode
Triode
air
air
air
air
air
8
8
13
8
14
UHF
UHF
UHF
UHF
UHF
Triode
Tetrode
Triode
Triode
Tetrode
air
air
air
air
air
8
8
15
16
UHF
UHF
UHF
UHF
UHF
Triode
Tetrode
Triode
Triode
Triode
air
air
air
air
air
17
8
8
8
18
UHF
UHF
FM
UHF
FM
Planar triode
Triode
Tetrode
Triode
Tetrode
air
air
air
air
air
19
FM
FM
FM
UHF
Radio
Tetrode
Tetrode
Tetrode
Tetrode
Tetrode
air
air
air
air
air
VHF
Radio
VHF
Radio
FM
Tetrode
Tetrode
Tetrode
Tetrode
Tetrode
air
air
air
air
air
VHF
FM
FM
VHF
Radio
Tetrode
Tetrode
Tetrode
Tetrode
Tetrode
air
air
air
air
air
8
8
20
8
21
31
f$ THOMSON TUBES ELECTRONIQUES
Refe~nce
Power
Band
TH 382
TH 390
TH 390 A
TH 392
TH 393
11 kW
2 kW
2 kW
10 kW
4.4 kW
UHF
UHF
UHF
UHF
UHF
Tetrode
Tetrode
Tetrode
Tetrode
Tetrode
air
air
air
air
air
32
8
8
8
33
TH 399
TH 476
TH 477
TH 478
TH 478 A
12 kW
200 kW
50 kW
250 kW
250 kW
Radio
Radio
Radio
Radio
Radio
Tetrode
Triode
Triode
Triode
Triode
air
water
water
water
water
34
8
8
8
8
TH 479
TH 483
TH 485
TH 487
TH 491 B
30 kW
40 kW
100kW
110 kW
25 kW
Radio
Radio
Radio
Radio
UHF
Triode
Triode
Triode
Triode
Tetrode
water
water
water
water
water
8
8
8
8
8
TH 4T1100
TH 4T4100
TH 504 C
TH 504 V
TH 520
2.3 kW
5 kW
300 kW
300 kW
70 kW
Radio
Radio
Radio
Radio
Radio
Tetrode
Tetrode
Triode
Triode
Tetrode
air
air
water
water
water
8
8
8
9
9
Radio
Radio
UHF
Radio
Radio
Tetrode
Triode
Tetrode
Tetrode
Tetrode
water
water
water
water
water
35
9
36
37
38
Radio
Radio
Radio
Radio
FM
Tetrode
Tetrode
Tetrode
Tetrode
Tetrode
water
water
water
water
water
9
9
39
9
9
UHF
Radio
Radio
Radio
Radio
Tetrode
Tetrode
Tetrode
Tetrode
Tetrode
water
water
water
water
water
40
9
9
41
42
VHF
Radio
UHF
VHF
Tetrode
Tetrode
Tetrode
Tetrode
water
43/44
water
water
water
45
46
47
Type
1
I
TH 561
TH 562
TH 563
TH 571 A
1
r,\ THOMSON TUBES ELECTRONIQUES
15 kW
12 kW
44 kW
41 kW
Cooling_-Page
5
Power-grid tubes
i IIYldLIUI
I
Thyratron
Thyratron
Cavity
9
Cavity
Cavity
new
20
21
Cavity
15
TH 18324
Cavity
13
TH 18326
TH 18327
TH 18346
Cavity
Cavity
Cavity
TH 18362
Cavity
14117
TH 18363
Cavity
TH 18462
Cavity
Cavity
16125
18119
Cavity
TH 18482
TH 18526
27
28
24
32
43
TH 18527
Cavity
Cavity
TH 18550
Cavity
TH 18563
Cavity
TH 18565
Cavity
52
TH 18582
Cavlty
51
TH 18665
Cavity
33
47
46
36140
MOMSON TUBES ELECTRONIQUES
Po wer-grid tubes
- -
Tube
selection
guide
Band and power output
Reference
Power
TYpe
TH 326
TH 308
TH 328
TH 338
TH 339
TH 327
TH 527
TH 347
TH 547
TH 393.
TH 593
TH 382
TH 582
TH 563
50 W
110 w
Il0 W
220 W
220 W
550 W
1 kW
2 kW
2 kW
44kW
44kW
11 kW
22 kW
44 kW
Triode
Triode
Triode
Triode
Planar triode
Tetrode
Tetrode
Tetrode
Tetrode
Tetrode
Tetrode
Tetrode
Tetrode
Tetrode
air
air
air
air
air
air
water
air
water
air
water
air
water
water
VHF Television
TH 225
TH 298
TH 375
TH 361
TH 561
TH 371
TH 571 A
250 W
2.2 kW
10 kW
15 kW
15 kW
21 kW
41 kW
Tetrode
Tetrode
Tetrode
Tetrode
Tetrode
Tetrode
Tetrode
air
air
air
air
water
air
water
FM Radio
TH 341
TH 344
TH 373
TH 345
TH 343
TH 346
I O kW
10 kW
10 kW
22 kW
30 kW
60 kW
Tetrode
Tetrode
Tetrode
Tetrode
Tetrode
Tetrode
air
air
air
air
air
air
Tetrode
Tetrode
Tetrode
Tetrode
Tetrode
Tetrode
Tetrode
Tetrode
Tetrode
Tetrode
Tetrode
Tetrode
Tetrode
Tetrode
Tetrode
water
air
air
water
water
water
water
water
water
water
water
water
water
water
UHF Television
-
AM Radio
LIMISW
-
Power a rndrcated on the
carrier for rad10 tubes and
peak-of-sync video for T V
tubes
1,\ THOMSON
TUBES ELECTRONIQUES
TH 349
TH 598
TH 376
TH 399
TH 561
TH 562
TH 532
TH 521
TH 581
TH 555 A
TH 537
TH 573
TH 558
TH 576
TH 539
Cooling
Page
12
13
30
27
43
28
47
20
22
29
23
21
24
air
7
Power-grid tubes
-
-
-
Replacement
tubes and
cavity
The following products continue to be offered as
replacements for existing transmitters, thus
guaranteeing availability. They are not proposed for
new designs, but should you require further
information on their performances, do not hesitate
to contact Thomson Tubes Electroniques.
-
Reference
--Power
\
.
-
Power is indicated as
carrier power for radio
tubes and peak of sync
video for T V transmitter
tubes.
Band
Type
Cooling
--
TH 287
TH 289
TH 289 MA
TH 290
TH 293
I O kW
2kW
3kW
I O kW
2kW
VHF
Radio
FM
UHF
UHF
Triode
Tetrode
Tetrode
Tetrode
Tetrode
air
air
air
air
air
TH 294
TH 306
TH 308 B
TH 313
TH 316
400 W
25 W
250 W
5kW
35 W
UHF
UHF
UHF
UHF
UHF
Triode
Triode
Triode
Tetrode
Triode
air
air
air
air
air
TH 331
TH 336
TH 337
TH 340
TH 342
1 kW
25 W
200 W
220 W
500 W
UHF
UHF
UHF
UHF
UHF
Tetrode
Triode
Triode
Triode
Triode
air
air
air
air
air
TH 354
TH 360
TH 362
TH 369
TH 374
10 kW
12 kW
12 kW
5kW
30 kW
VHF
Radio
Radio
FM
FM
Tetrode
Tetrode
Tetrode
Tetrode
Tetrode
air
air
air
air
air
TH 390
TH 390 A
TH 392
TH 476
TH 477
2kW
2kW
lOkW
200 kW
50 kW
UHF
UHF
UHF
Radio
Radio
Tetrode
Tetrode
Tetrode
Triode
Triode
air
air
air
water
water
TH 478
TH 478 A
TH 479
TH 483
TH 485
250 kW
250 kW
30 kW
40 kW
100 kW
Radio
Radio
Radio
Radio
Radio
Triode
Triode
Triode
Triode
Triode
water
water
water
water
water
TH 487
TH 491 B
TH 4T1100
TH 4T4100
TH 504 C
110 kW
25 kW
2.3 kW
5 kW
300 kW
Radio
UHF
Radio
Radio
Radio
Triode
Tetrode
Tetrode
Tetrode
Triode
water
water
air
air
water
a
-
,,\ THOMSON TUBES ELECTRONIQUES
1
Po wer-grid tubes
Power
-.
300 kW
70 kW
250 kW
300 kW
300 kW
Band
-
-_Type.._ - Cooling
Radio
Radio
Radio
Radio
Radio
Triode
Tetrode
Triode
Tetrode
Tetrode
water
water
water
water
water
Radio
FM
Radio
Radio
Radio
Tetrode
Tetrode
Tetrode
Tetrode
Tetrode
water
water
water
water
water
Radio
Radio
Radio
UHF
UHF
Tetrode
Tetrode
Tetrode
Tetrode
Tetrode
water
water
water
water
water
Thyratron
Thyratron
Thyratron
Cavity
1
Gb THOMSON
TUBES ELECTRONIQUES
FMNHF tetrode
i Output
power
250 W
up to 500 MHz
General characteristics
Cathode ........................................................................................
oxide
Heating(1) .................................................. direct, dc or single phase
lnterelectrode capacitances, approx.:
Ground/cathode connection:
..........
.............................1 5 7 pF
input .....................
.
.
.......
output ..............................................................................
4.5 pF
....0.04 pF
feed-through .........................................................
.
.
Groundlgrid connection:
input .............................. .......... .........................................
13 pF
output .......................
.
.
.............................................. 4.5 pF
feed-through ................................................................ 0 0 pF
Amplification factor, average .........................
.
................................ 5
Transconductance (la = 0.2 A, Vg2 = 250 V) ..........................12 mA1V
Operating position ......................................................................... anY
Weight, approx.....................
.
.................................................
140 g
Dimensions ...................................................................
s e page 55
Anode, electrode terminal and ceramic cooling (2):
type ......................................................................... forced air
temperature on the tube, max. ............................................250 OC
TYpical operation
carrier conditions
Maximum ratings
Anode voltage ...................................... 2 kV
Control-grid voltage .............................-250 V
Screen-grid voltage ...............................400 V
Peak cathode current .........................250 mA
Anode dissipation ................................250 W
Control-grid dissipation ............................2 W
Screen-grid dissipation .......................... 12 W
(1) Thomson Tubes Electroniques defines the operating
voltage according to each particular situat~on.As an
indication for equipment design purposes only, a heater
voltage of 6 Vproduces a heating current of 2.6 A.
(2) Values for cooling given for maximum anode
dissipahon.
output power
250
W
Frequency
500
MHz
2
kV
Screen-grid voltage
250
V
Control-grid bias voltage
- 90
Anode cubent
250
Anode voltage
Screen-grid current
10
Control-grid current
1O
mA
<! THOMSON TUBES ELECTRONIQUES
FMNHF tetrode
i Output power
up to 2.2 kW
peak-of sync in common amplification
3.75 kW in sound carrier amplification
3 kW in FM radio transmitters
General characteristics
Cathode ...................................................................thoriated tungsten
Heating (1) ..................................................................................direct
lnterelectrode capacitances, approx.:
cathode-control grid .............................................................4 0 pF
........................75 pF
control grid-screen grid ..............................
.
11.5 pF
screen grid-anode ...............................................................
Amplification factor, average ..............................................................
7
Transconductance (la = 1.5 A, Vg2 = 600 V) ..........................40 m A N
Operating position ...................................... -ciaI
Weight, approx. ..............................................................................
2 kg
Dimensions ................................................................s e page 55
Anode cooling ( 2 )..................................................................
f o r c e air
air flow, min. ......................................................................5 mJ/mn
corresponding pressure drop ...........................................5 mbar
outlet air temperature, less than .....................................
100 OC
Electrode terminal and ceramic seal cooling
type ..................................................................................
forced air
temperature on the tube, max ..............................................
250 "C
Maximum ratings
Frequency ........................................
300 MHz
.......... 5 kV
Anode voltage ........................
.
Anode current ..............................
....... 2.5 A
Anode dissipation ...................................
5 kW
Control-grid dissipation ...................... ..40 W
Screen-grid dissipation ......................... 60 W
( 1 ) Thomson Tubes Electroniques dehnes the operatmg voltage accordmg to each particular situat/on
As an indlcabon for equipment design purposes only, a heater voltage of 6 V produces a heaiing current of 50 A
(2) Values for cool~nggiven for max~mumanode d~ssipation
Common Sound
amplification only
Typical operation
at 178 MHz
TV operation in the
matched cavity
TH 18324A
TH 18324A
- Sound carrier output power
Peak-of-sync output power
- 1 d B bandwidth
- 3 d B bandwidth
> 300
kW
kW
MHz
kHz
23
dB
dB
3.75
3
2.2
8
Intermodulation products
- 48
Gain
14
Anode voltage
4.5
Screen-grid voltage
500
Anode current, with signal
1.35
Screen-grid current
1O
Control-grid current
negligible
Anode current at zero signal
0.6
matched circuit assembly
FM
radio
4
16.5
5
5
500
1.5
50
negligible
0.6
400
0.8
20
35
0.1
kV
V
A
mA
mA
A
---.
l
For UHF-TV transmitters and translators
(Band III)
Operating frequency ....................................................178 to 227 MHz
Dimensions ....................................................760 x 278 x 178 mm
Weight, approx (without tube) .......................................:...........25 kg
RF connections:
input ....................................................................... f e m a e type N
output .......................................standard EIA rigid coaxial line 718"
Cooling ..................................................................................forced air
I,\ THOMSON TUBES ELECTRONIQUES
13
/
UHF triode
Output power
upto 110 W
peak-of sync in common amplification
General characteristics
Cathode ......................................................................................
oxide
Heating (1) ...............................................................................indirect
lnterelectrode capacitances, approx.:
cathode-grid ........................................................................ 16 pF
cathode-anode ...................................................................
0 . 1 pF
grid-anode ......................................................................
7.3 pF
Amplification factor, average ............................................................
80
Transconductance (la = 0.25 A) ......................................... 45 mA/V
Operathg position ..........................................................................
any
Weight, approx.. ...........................................................................
g
Dimensions .....................................................................S
page 55
Anode cooling (2).......................................................................
air
air flow, min. ......................................................................
450 Ilmn
corresponding pressure drop ...........................................O.
mbar
outlet air temperature, max. ....................................................
OC
Electrode terminal and ceramic seal ~00ling
type ............................................................................... forced air
5 0 "C
temperature on the tube, max. .............................................
:
Maximum ratings
Frequency ......................................1000 MHz
Voltage .................................................2.2 kV
Anode current ........................................0.6 A
Anode dissipation ................................700 W
(1) Thomson Tubes Electroniques defines the operaling voltage according to each particular situation
As an indicat~onfor equipment design purposes only a heater voltage of 6 3 V produces a heating current of 6 A
(2) Values for cooling given for maximum anode dissipation
Common
amplification
T~~ical
at 780 MHz
I
in the matched cavity
TH 18362
Peak-of-sync output power
- 1 dB bandwidth
110
W
10
MHz
0.2
A
Intermodulation products
Gain
Anode voltage
Grid voltage
Anode current, with signal
Anode current at zero signal
I
I
I
I
TH 18362
matched circuit assembly
dm&
- .-A-
.z---
For UHF-TV transmitters and translators
(Bands IV and V)
460 to 860 MHz
Operating frequency ....................................................
571
.5
x
260 x 162 mm
.......................................................
Dimensions
O kg
......................................................
Weight, approx (without tube)
RF connections:
input ....................................................................
female, type BNC
output .........................: .............................................
female, type N
Cooling ...............................................................................
forced air
14
y
#
y
THOMSON TUBES ELECTRONIQUES
UHF triode
i Output
power
up to 50 W
peak-of sync in common amplification
General characteristics
Cathode ......................................................................................~oxide
Heating (1) ...................................................................................
lnterelectrode capacitances, approx.:
cathode-grid ......................................................................... 22 pF
cathode-anode ............................................................... 0 0 5 pF
grid-anode .............................................................................
3 9 PF
Amplification factor, average ..........................................................250
Transconductance (la = 0.15 A) .............................................80 m A N
Operating position .......................................................................... anY
Weight, approx. ................................................ . . . . . . . . . . . . . 170
. g
Dimensions ....................................................................... s e page 55
Anode cooling (2) ...................................................................foced air
air flow, min. ......................................................................
280 I/mn
corresponding pressure drop ...........................
.
.
.........0 5 mbar
outlet air temperature, max. ................................ .
.
...........0 0 OC
Electrode terminal and ceramic seal cooling
air
type .......................................................................................
.
..............150 "C
temperature on the tube, max. ..........................
Maximum ratings
Frequency ..................................
1000 MHz
Voltage. ............................
2
kV
Anode current ...........................
...
250 mA
Anode dissipation ..............................-270 W
( 1 ) Thomson Tubes Electroniques defines the operating voltage according to each par?icular Situabon
As an ~ndicationfor equipment design purposes only, a heater voltage of 5 Vproduces a heating current of 2 A.
(2) Values for cooling given for anode dissipation of 200 W.
Common
amplification
T Y P ~ operation
c~~
at 780 MHz
in the matched cavity
TH 18261
Peak-of-sync output power
50
W
- 1 dB bandwidth
1O
MHz
- 53
dB
Gain
20
dB
Anode voltage
1.8
kV
intermodulation products
Grid voltage
Anode current, with signal
Grid current
Anode current at zero signal
TH 18261
negligible
mA
140
matched circuit assembly
For UHF-TV transmitters and translators
(Bands IV and V)
Operating frequency ....................................................470 to 960 MHz
Dimensions ..........................................................460 x 240 x 150 mm
Weight, approx (without tube) ........................................................6 kg
RF connections:
input .............................................................. f e m a e type BNC
output .......................................................................female, type N
Cooling ...................................................................................foced air
.
.
UHF tetrode
Output power
up to 550 W
peak-of sync in common amplification
up to 1.2 W in sound carrier amplification
General characteristics
Cathode ..................................................................t h o a e d tungsten
Heating (1 ) ......................................... .........................................direct
lnterelectrode capacitances, approx.:
cathode-control grid ...............................................................
O PF
control grid-screen grid .......................................................PF
screen grid-anode .................................................................
8,2 pF
Amplification factor, average ............................................................ 7
Transconductance (la = 1.5 A, Vg2 = 400 V) .......................... 40 m A N
Operating position ....................................................................
veriical
Weight, approx .......................................................................... 2.3 kg
page 55
Dimensions ...................................................................
....................................... forced air Maximum ratings
Anode cooling (2)...................
.
.
air flow, min. ......................................................................
2 m3/mfl Frequency .......................
.......1000 MHz
.
.
.
.....................2 mbar Anode voltage ......................
corresponding pressure drop ....................
........ 5 kV
.
.
.
.
............0 0 "C Anode current .......................... .
......... 2 A
outlet air temperature, max. ............................ .
.
Anode dissipation ................................4.5 kW
Electrode terminal and ceramic seal cooling
Control-grid dissipation ............................5 W
air
type .................................................................................
Screen-grid dissipation ..........................25 W
temperature on the tube, max. .............................................250 O C
(1) Thomson Tubes Electroniques defines the operating voltage according to each particular situation.
As an indication for equjpment design purposes only, a heater voltage of 6 V produces a heating currenf of 34 A
(2) Values for cooling given for anode dissipation of 2 kW.
Common
amplification
Typical operation
at 800 MHZ
in the matched cavity
TH 18363
~eak-of-syncoutput power
Sound carrier output power
- 1 dB bandwidth
Intermodulation products
Anode voltage
Screen-grid voltage
Anode current, with signal
Screen-grid current
Control-grid current
Anode current at zero signal
TH 18363
Sound
only
550
1O
1200
1O
- 54
15.5
15.5
3.5
400
0.65
2
negligible
0.5
4
400
1
5
negligible
0.5
W
W
MHz
dB
dB
kV
V
A
mA
A
matched circuit assembly
For UHF-TV transmitters and translators
(Bands IV and V)
Operating frequency ..........................
.
....................470 to 860 MHz
Dimensions .....................................................
644 x 268 x 200 mm
20 kg
Weight, approx (without tube) ...................................................
RF connections:
input .................................... ...................................f e m a e type N
output ..
EIA 718"
Cooling .............................................................................forced air
16
THOMSON TUBES ELECTRONIQUES
UHF triode
i
Output power
up to 110 W
peak-of sync in common amplification
General characteristics
-Cathode ..................................................................................... oxide
Heating (1) ................................................................................
indirect
lnterelectrode capacitances, approx.:
cathode-grid ...........................................................................
19 pF
cathode-anode ..................................................................0.07 pF
grid-anode .............................................................................
8 2 pF
Amplification factor, average ...........................................................180
Transconductance (la = 0.4 A) ..............................................85 m A N
Operating position ..........................................................................anY
Weight, approx ............................................................................. 950 g
Dimensions ....................................................................... s e page 55
Anode cooling (2) ............................................................... f o r c e air
air flow, min. .................................................................... 470 I/mn
corresponding pressure drop .....................
................ 1 mbar
outlet air temperature, max. .........................
..................... 0 0 " C
Electrode terminal and ceramic seal cooling
type ...............................................................................
f o r c e air
.
............... 250 OC
temperature on the tube, max. ....................
.
.
.
Maximum ratings
Frequency .....................................,1000 MHz
Anode voltage ......................................
2.2 kV
Anode current ...................................... 0.6 A
.....750 W
Anode dissipation ...................
.
.
.
(1) Thomson Tubes Electroniques defines the operating voltage accor8ng fo each paificular situation.
As an ~ndicatronfor equipment design purposes only. a heater voltage of 5.5 V produces a heahng current of 5.4 A
(2) Values for cooling given for maximum anode dissipation.
Common
amplification
T~~ical
at 780 MHz
in the matched cavity
TH 18362
Peak-of-sync output power
110
W
1O
MHz
- 52
dB
Anode current, with signal
0.43
A
Anode current at zero signal
0.4
A
- 1 dB bandwidth
Intermodulation products
Gain
Anode voltage
Grid voltage
i
I
i
r
i
TH 18362
matched circuit assembly
For UHF-TV transmitters and translators
(Bands IV and V)
Operating frequency .................................................... 460 to 860 MHz
Dimensions ................................................... 5 7 . 5 x 260 x 162 mm
Weight, approx (without tube) ...................................................1O kg
RF connections:
input .................................................................... f e m a e type BNC
output ...................................................................... f e m a e type N
Cooling .................................................................................forced air
S FI FCTRONIQUES
1
1
17
UHF tetrode
a Output power
up to 550 W
peak-of sync in common amplification
up to 1.2 W in sound carrier amplification
General characteristics
Cathode .................................................................
thoriated tungsten
Heating (1) ...................................................................................dire~t
lnterelectrode capacitances, approx.:
cathode-controlgrid ...............................................................
0 pF
control grid-screen grid .........................................................
50 pF
screen grid-anode.................................................................
8.2pF
Amplification factor, average ..............................................................
7
Transconductance (la = 1.5A, Vg2 = 400 V) .......................... 40 m w
Operating position ....................................................................
v€?t?icaI
Weight, approx ............................................................................
2.3 kg
Dimensions .......................................................................See
page 55
Anode cooling (2)................................................................ forced air
Maximum ratings
......
..................................
2 m3/mn Frequency .....................................
air flow, min. .....................
.IO00MHz
5 kV
corresponding pressure drop ..............................................
2 mbar Anode voltage .........................................
OC Anode current .......................................... 2 A
outlet air temperature, max. .................................................lOO
Anode dissipation............................... 4.5kW
Electrode terminal and ceramic seal cooling
type ...............................................................
. . . . . . . .forced air Control-grid dissipation ............................5 W
"C Screen-grid dissipation .......................... 25 W
temperature on the tube, max. ............................................
( 1 ) Thomson Tubes Electroniques defiries the operating voltage according to each parttcular situabon
As an indication for equipment design purposes only, a heater voltage of 6 V produces a heating currenf of 34 A.
(2) Values b r cool~nggiven for anode dissrpalion of 2 kW
Common
amplification
Typical operation
at 800 MHz
in the matched cavity
TH 18363
~eak-of-syncoutput power
550
1200
Sound carrier output power
- 1 dB bandwidth
10
1O
- 54
lnterrnodulation products
W
W
MHz
dB
15.5
dB
3.5
4
Screen-grid voltage
400
400
Anode current, with signal
0.65
1
2
5
negligible
0.5
kV
V
A
mA
15.5
Anode voltage
Screen-grid current
Control-grid current
negligible
0.5
Anode current at zero signal
TH 18363
Sound
only
matched circuit assembly
,_*. .-
For UHF-TV transmitters and translators
(Bands IV and V)
Operating frequency .................................................470 to 860 MHz
644 x 268 x 200 mm
Dimensions ........................................................
Weight, approx (without tube) ......................................................20 kg
RF connections:
input ........................................................................femae type N
output ................................................................. standard EIA 718"
Cooling................................................................................. foced air
A
t
.
THOMSOM TUBES ELECTRONIQUES
UHF triode
Output power
up tu 220 W
peak-of sync in common amplification
General characteristics
Cathode ....................................................................................oxide
Heating (1) .......................................................................indirect
lnterelectrode capacitances. approx.:
cathode-grid ...........................................................................
16 pF
cathode-anode ............................................................... 0 13 pF
grid-anode .............................................................................
7.3 pF
Amplification factor, average ...........................................................80
Transconductance (la = 0.25 A) ..............:............................ 45 m m
Operating position ........................................................................ anY
Weight, approx. ...........................
.
........................................... 1.2 kg
page 55
Dimensions ..........................................................................
Anode cooling (2) ......................................................................... air
air flow, min. ....................................................................
1250 Ilmn
corresponding pressure drop ...........................................4.5 mbar
outlet air temperature, max. ............................................... 0 0 OC
Electrode terminal and ceramic seal cooling
type ..................................................................................
forced air
250 OC
temperature on the tube, max. .........................................
I
Maximum ratings
Frequency ......................................1000 MHz
........2.5 kV
Anode voltage ......................... .
.
Anode current ........................................0.6 A
Anode dissipation .............................. 1.2 kW
( 1 ) Thomson Tubes Electroniques defines the operahng voltage according to each pa~ticularsituation
As an ind~cahonfor equipment design purposes only, a heater voltage of 6 3 V produces a heating current of 6 A
(2) Values for cooling given for anode dissipation of 1 kW
Common
amplification
T~~ical
at 780 MHz
in the matched cavity
TH 18462
220
W
- 1 d B bandwidth
1O
MHz
lntermodulation products
,52
dB
0.4
A
Peak-of-sync output power
Gain
Anode voltage
Grid voltage
Anode current, with signal
Anode current at zero signal
I
I
1,
1
I
TH 18462
--.&::y-..
&-;a-
matched circuit assembly
For UHF-TV transmitters and translators
(Bands IV and V)
......................460 to 860 MHz
Operating frequency .................. .
.
5 7 .5 x 260 x 162 mm
Dimensions ..................................................
Weight, approx (without tube) .....................................................
kg
RF connections:
input .........................
.
..................................
f e m e , type BNC
.
..........................................
female, type N
output ........................
.............................................................. forced air
Cooling ...............
.
18
I
-
1,\ IHOMSON TUBES ELECTRONIQUES
UHF triode
up to 220 W
peak-of sync in common amplification
General characteristics
.. ..oxide
Cathode ................................................................... ......
Heating (1) .............................................................................. indirect
lnterelectrode capacitances, approx.:
cathode-grid ......................................................................... 19 pF
cathode-anode .....................
.
.
...................................... 0 0 7 pF
grid-anode ...................................................................... .7.3 pF
Amplification factor, average ........................................................ 180
5 mA/V
Transconductance (la = 0.4 A) ...................................... 8
Operating position ..........................................................................
anY
Weight, approx ............................................................................
1.2 kg
s e page 55
Dimensions ...................................................................
Anode cooling (2)................................................................ f o r c e air
air flow, min. .................................................................. 1250 Ilmn
corres~ondina
d r o ~ max
,
............................... ,425 mbar
- ,~ r e s s u r e
outlet air temperature, max. ...........................................
100 OC
Electrode terminal and ceramic seal coolinq
type ............................................................................... f o r c e air
250 OC
temperature on the tube, max. .............................................
Maximum ratings
Frequency ......................................
1000 MHz
Anode voltage ......................................2.2 kV
...........0.6 A
Anode current ........................
.
Anode dissipation ........... .
.
..............1.2 kW
( 1 ) Thomson Tubes Electron~quesdefines the operating voltage according to each pati~cularsituation
As an indication for equlpment design purposes only, a heater voltage of 5 5 V produces a heatlng current of 5 5 A
(2) Values for cool~nggiven for anode dissipabon of 1 kW
Common
amplification
T ~ ~ i cOperation
al
at 780 MHz
in the matched cavity
TH 18462
I
I
I
I
I
1
TH 18462
Peak-of-çync output power
220
W
1O
MHz
- 52
dB
Gain
20
dB
Anode voltage
2.0
kV
Grid voltage
-9
V
Anode current, with signal
0.45
A
Anode current at zero signal
0.35
A
- 1 dB bandwidth
lntermoduiation products
matched circuit assembly
For UHF-TV transmitters and translators
(Bands IV and V)
.....460 to 860 MHz
Operating frequency ........................................
.
.
Dimensions ...............................................
571 .5 x 260 x 162 mm
Weight, approx (without tube) ......................................................
10 kg
RF connections:
input ....................................................................f e m a e type BNC
output .......................................................................f e m a e type N
Cooling .................
.
..............................................................f o r c e air
L b THOMSON TUBES ELECTRBNIOUES
l
---A.,
%.+
19
FM tetrode
i Output
in
power
up to 10 kW
FM r a d i o t r a n s m i t t e r s
General characteristics
Cathode ..................................................................
horiated tungsten
Heating (1) ....................................................direct,
dc or single phase
lnterelectrode capacitances, approx.:
cathode-control grid ..........................................................
2
pF
control grid-screen g r d .
..............................................135 PF
screen grid-anode ...............................................................
'9 PF
Amplificafion factor, average ...........................................................
5.5
Transconductance (la = 0.15 A, Vg2 = 500 V) ........................
60 mAiV
Operating position ..................................................................
..ve"cal
Weight, approx ...........................................................................
3.5 kg
Dimensions .....................................................................S
page 55
Anode cooling (2) .............................................................
forced air
air flow, min. ..................................................................
....6 m3/mn
corresponding pressure drop ........................................1.5 mbar
outlet air temperature, max. ...............................................100 OC
Electrode terminal and ceramic seal ~ 0 0 l i n g
type ..................................................................................
forced air
250 OC
temperature on the tube, m a x .............................................
Maximum ratings
Frequency ........................................120 MHz
Anode voltage .........................................8 kV
Anode current ..........................................6 A
Anode dissipation ...................................6 kW
Control-grid dissipation ..........................50 W
Screen-grid dissipation ........................150 W
(1) Thomson Tubes Electroniques defines the operating voltage according to each particular situabon
As an indication for equipment design purposes only, a heater voltage of 6 5 Vproduces a heating current of 85 A
(2) Values for cooling given for maximum anode dissipation
TH18108K
TH 18108G
Grounded-grid Grounded-cathode
operation
operation
TYpical ope ration
at 108 MHz
in the matched cavity
TH 18108
1O
1O
kW
300
300
kHz
Gain
17
21
dB
Anode voltage
7
6.5
kV
400
output power
- 0.2 d~ bandwidth
Screen-grid voltage
v
Anode current, with signal
2
500
1.95
Screen-grid current
60
70
mA
Control-grid current
30
30
mA
0.25
0.05
A
Anode current at zero signal
A
l
TH 1810 8 M H 18108K matched circuit assemblies
For FM radio transmitters
87 to 108 MHz
Operating frequency ......................................................
555
x
455 x 241 mm
.....................................
Dimensions. TH 18108G
561 x 340 x 241 mm
Dimensions, TH 18108K ......................................
. . .38 kg
Weight, approx (without tube), TH 18108G .................-
Weght, approx (without tube), TH 18108K ..................................
25 kg
RF connections:
input .......................................................................
fernale. type N
output . . . . . . . .,........................................
EIA standard 1 518''
Cooling ................................................................................forced air
,,\ THOMSON TUBES ELECTRONIQUES
FM tetrode
Output power
up to 30 kW
in FM radio transmitters
General characteristics
Cathode ..................................................................
thoriated tungsten
direct, dc or single phase
Heating (1) ....................................................
lnterelectrode capacitances, approx.:
cathode-control grid ............................................................. 110 pF
control grid-screen grid .......................................................2 5 pF
screen grid-anode ..................................................................28 pF
Amplification factor, average ..............................................................
7
Transconductance (la = 2 A, Vg2 = 500 V) ...........................1O0 m A N
Operating position ..................................................................vertical
Weight, approx. ........................
..................................................
6 kg
Dimensions .......................................................................
s e page 55
Anode cooling (2)...................................................................forced air
air flow, min. ....................................................................4 m3tmn
corresponding pressure drop ..............................................5 mbar
O "C
outlet air temperature, max. .................................................
Electrode terminal and ceramic seal cooling
type ..................................................................................forced air
temperature on the tube, max. ........................................... 250 OC
Maximum ratings
Frequency ........................................
120 MHz
Anode voltage ...................................... 1O kV
Anode current ........................................ 7 A
Anode dissipation ...............................8 kW
Control-grid dissipation ........................100 W
.Screen-grid dissipation ........................300 W
( 1 ) Thomson Tubes Electroniques defines the operating voltage according to each particular situation.
As an indication for equipment design purposes only, a heater voltage of 7.6 Vproduces a heating current of 120 A.
(2) Values for cooling given for anode dissipation of 12 kW
Example 1
Example 2
20
30
kW
300
300
kHz
Gain
17
18
dB
Anode voltage
8.5
9.5
kV
Screen-grid voltage
500
600
V
Anode current, with signal
2.9
4.2
A
Screen-grid current
120
220
mA
Control-grid current
30
4
mA
0.05
0.5
A
Grounded-grid operation
TYpical operation
at 108 MHz
in the matched cavity
TH 18230G
output power
- 0.2 dB bandwidth
Anode current at zero signal
TH 182306
matched circuit assembly
For FM radio transmitters
Operating frequency ...................................................
87.5 to 108 MHz
800 x 580 x 483 mm
Dimensions ..........................................................
63 kg
Weight, approx (without tube) ....................................................
RF connections:
input .........................................................................femae type N
output ............................................................. EIA standard 3 118"
Cooling ...................................................................................f o r c e air
TH 343
FM tetrode
rn Output power
in FM radio transmitters
b-
i
a*
)*V///Ib\\i
General characteristics
Cathode ..................................................................
thoriated fungsten
Heating (1) .................................................direct. dc or single phase
lnterelectrode capacitances, approx.:
cathode-control grid ............................................................110 PF
control grid-screen grid .......................................................215 PF
screen grid-anode ..................................................... 2
8 PF
Amplification factor, average ..................................................7
Transconductance (la = 2 A, Vg2 = 500 V) ...........................100 m A N
Operating position ...................................................................~eflical
Weight, approx ...............................................................................
6 kg
Dimensions ..................................................................
See page 55
Anode cooling (2) ...................................................................
forced air
air flow, min. .................................................................. 14 m3/mn
corresponding pressure drap ..............................................
5 mbar
outlet air temperature, max. .................................................
100 OC
Electrode terminal and ceramic seai cooling
type .....................................................................
air
temperature on the tube, max. .............................................250 O C
,
. * a
..
e V '
Maximum ratings
Frequency ..................................... 120 MHz
Anode voltage . ...,... ........................
1
0 kV
7A
Anode current ..........................................
Anode dissipation .................................
18 kW
Control-grid dissipation ....................100 W
Scieen-grid dissipation ....................3 0 0
( 1 ) Thomson Tubes E/ectroniques defines the opeiating voltage according to each paflicular situalon,
an
for eq~ipmentdesign purposes only, a heater voltage of 7.6 V produces a heating current of 120 A
(2) values for cooling given for anode dissipation of 12 kW.
Example 1
Example 2
output power
20
- 0.2 dB bandwidth
300
30
300
kHz
Gain
17
18
dB
Anode voltage
8.5
9.5
kV
Screen-grid voltage
500
600
v
Anode current, with signal
2.9
4.2
A
Screen-grid current
220
Control-grid current
120
30
4
mA
mA
Anode current at zero signal
0.05
0.5
A
Grounded-grid operation
TYpical operation
ât 108 MHz
in the matched cavity
TH 182306
TH 182306
matched circuit assembly
For FM radio transmitters
81.5 to 108 MHz
Operating frequency ...................................................
O
X 580 X 483 mm
..........................................................
Dimensions
63 kg
Weight, approx (without tube) ......................................................
RF connections:
input ...................................................................
......fernale,type N
output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
standard 3 118"
Cooling .........................................................................................
air
kW
FM tetrode
i Output
power
up to 15 kW
in FM radio transmitters
1
"JTHIIMSON TUBES
ELECTRONIOUES
General characteristics
Cathode ..................................................................
thoriated tungsten
Heating (1) ....................................................................direct,
dc or ac
lnterelectrode capacitances, approx.:
cathode-control grid ...............................................................
95 pF
control grid-screen .................................................................
76 pF
screen gïid-anode ..................................................................
22 pF
1 .......8
Amplification factor, average ......................................................
Transconductance (la = 3 A, Vg2 = 800 V) .............................53 mA/V
Operating position ............................................................................
Weight, approx............................................................................
6.7 kg
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page
.
55
Anode coollng (2) ................................................................. forced air
air flow, min. ....................................................................12 m3/mn
corresponding pressure drop ..............................................
9 rnbar
outlet air temperature, max. ................................................
1O "C
Electrode terminal and ceramic seal cooling
type .................................................................................
forced air
220 OC
.............................................
temperature on the tube, max.
(250 "C on grid connections)
Maximum ratings
Frequency ........................................
120 MHz
Anode voltage ........................................
9 kV
Anode current ..........................................6 A
Anode dissipation ...............................1 kW
Control-grid dissipation ........................100 W
Screen-grid dissipation ........................ 300 W
( 1 ) Thomson Tubes Eiectroniques deiines the operating
voltage according 10 each parlicular situation As a n
~ndicationfor equ~pmenldesrgn purposes only a healer
voltage ol 9 5 V produces a heating cufrenl of 80 A
(2) Values for c o o l i n g g i v e n for m a x i m u m a n o d e
diss~pation
Example 1
Example 2
15
1O
kW
- 0.2 d B bandwidth
300
23
300
23
kHz
CIB
Anode voltage
8.5
7.5
kV
Screen-grid voltage
750
700
V
Control-grid bias voltage
- 90
- 100
v
Anode current, with signal
2.5
1.9
A
Screen-grid current
250
mA
Control-grid current
30
180
20
"
T y ~ i c aoperation
l
at
MHz
Class B amplification,
Grounded-cathode
operation
'*
1i
22
output
pawer
mA
THOMSON TUBES ELECTRONIQUES
FM tetrode
i Output
power
up to 22 kW
in FM radio transmitters
iHOIWI
ELmwIoUEs
TUEES
<
-u,
General characteristics
Cathode ..................................................................t h o r i a e tungsten
Heating (1) ........................................................................
dc or ac
lnterelectrode capacitances, approx.:
cathode-control grid ............................................................. 82 pF
control grid-screen grid ........................
.
.
....................128 pF
screen grid-anode ................................................................ 21 pF
Amplification factor, average ..............................................................
7
Transconductance (la = 3 A, Vg2 = 800 V) ........................... 80 m A N
Operating position ....................................................................
vertical
Weight, approx. ..............................................................................7 kg
Dimensions .......................................................................see page 55
Anode cooling (2)...................................................................
f o r c e air
air flow, min. ....................................................................22 m3/mn
corresponding pressure drop ......................................
9
mbar
outlet air temperature, max.
O
OC
Electrode terminal and ceramic seal cooling
type ...................................................................................
air
220 OC
temperature on the tube, max. ........................................
(280 O C on heater connections)
...........................................
at 'O8 MHz
Grounded-grid
operation
Maximum ratings
Frequency ........................................
120 MHz
Anode voltage ......................................12 kV
Anode current ....................
.
..................6 A
.......6
Anode dissipation ..................
.
kW
Control-grid dissipation ..........................
70 W
Screen-grid dissipation ........................270 W
( 1 ) Thomson Tubes E'ertroniques defines the operahng
voltage according Io each particuiar situation As an
indication for equipmeiit design purposes only a heater
voitage of 9 V produces a heating current of 120 A
(2) Values for coo1ii.g given for maxfmum a n o d e
dissipaOon
Example 1
Example 2
300
18
300
16
kHz
dB
9
9
kV
600
800
V
- 140
- 140
V
Anode current, with signal
1.6
3.4
A
Screen-grid current
1O0
230
mA
Control-grid current
5
20
mA
- 0.2 dB bandwidth
Gain
Anode voltage
Screen-grid voltage
Control-grid bias voltage
FM tetrode
i Output
power
up to 60 kW
in FM radio transmitters
General characteristics
l
I
I
I
I
Cathode ..................................................................
horated tungsten
drect dc or single phase ac
Heating (1) ...............................................
lnterelectrode capacitances, approx.:
cathode-contrai grid .............................................................
1O pF
control grid-screen grid ........................................................... pF
screen grid-anode ..................................................................
O pF
Amplification factor, average ..............................................................
6
110 mA/V
Transconductance (la = 5 A, Vg2 = 800 V) ........................
Operating position ........................................................................
Weight, approx .............................................................................
26 kg
Dimensions .......................................................................Se page 55
Maximum ratings
Frequency ........................................
120 MHz
Anode c001ing (2)...................................................................
forced air
. 1 kV
air flow, min. ....................................................................
25 m3/mn Anode voltage ......................................
0 0 "C Anode current ...................................... 25 A
outlet air temperature, max. .................................................
Anode dissipation .................................
30 kW
Electrode terminal and ceramic seal cooling
Control-grid dissipation ........................300 W
air
type ..................................................................................forced
temperature on the tube, max. ................................................
"C Screen-grid dissipation ........................600 W
(1) Thomson Tubes Electroniques defines the operabng voltage accord~ngto each particular situation
As an indication for equipmenf deslgn purposes only. a heater voltage of 10 V produces a heating current of 210 A
(2) Values for cooiing given for maxlmum anode d~ssssipation
I
I
I
Grounded-grid
operation
TYpical operation
at 108 MHz
in the matched cavity
TH 18346
output power
60
kW
- 0.2d B bandwidth
300
kHz
Gain
14
dB
Anode voltage
1O
kV
1O00
V
Screen-grid current
380
rn A
Control-grid current
370
mA
Screen-grid voltage
Control-grid bias voltage
Anode current, with signal
TH 18346
matched circuit assembly
For FM radio transmitters
I
-Y
--
Operating frequency ..........................................
Dimensions ........................................................
x 580 x 483 mm
........................ 65 kg
Weight, approx (without tube) ......................
.
RF connections:
input ...................................................................femae type 718"
output ............................................. .............A standard 3 1/8"
Cooling................................................................................... forced air
24
THOMSON TUBES ELECTRONIQUES
UHF tetrode
i Output power
upto 1.1 k W
peak-of-sync in common amplification
2.2 kW peak-of-sync in vision carrier amplification
General characteristics
Cathode ..................................................................
thoriated tungsten
Heating (1) ..............................................direct, dc or single phase ac
lnterelectrode capacitances, approx.:
cathode-control grid ............................................................. 40 pF
control grid-screen grid ..........................................................
50 pF
screen grid-anode ........................
.
.
.
.............................
8.2 pF
Amplification factor, average ............................................................ 7
Transconductance (la = 1.5 A, Vg2 = 400 V) ........................ 40 m A N
Operating position ....................................................................veflical
Weight, approx .......................................................................... 2.3 kg
s e page 55
Dimensions ....................................................................
Anode cooling (2) ................................................................. f o r c e air
air flow, min. ...................................................................
2.5 m3/mn
air inlet pressure, max ..........................................................
3 mbar
outlet air temperature, max. ............................................ 0 0 OC
Electrode terminal and ceramic seal cooling
type ...............................................................................
forced air
temperature on the tube, max. ........................................... 250 ' C
Maximum ratings
....1000 MHz
Frequency ....................
......,.
....5 kV
Anode voltage ........................... .
.
.
Anode current .......................................... 2 A
Anode dissipation ................................4.5 kW
Control-grid dissipation ............................5 W
Çcreen-grid dissipation ..........................25 W
( 1 ) Thomson Tubes Electronrques defrnes the operating voltage according Io each particular situation
As an ~ndicationfor equipment design purposes only. a heater voilage of 6 Vproduces a heating curretlt of 34 A
(2) Values for coolrng g ~ v e nfor anode dissipabon of 2 5 kW
Typical operation
at 800 MHz
in the matched cavity
TH 18363
Common
amplification
Vision
only
Peak-of-sync output power
1.1
2.2
- 1 d~ bandwidth
1O
1O
Intermodulation products
- 54
Gain
15.5
15.5
dB
4
4
kV
Screen-grid voltage
400
400
V
Anode current, with signal
0.8
1.5
A
Screen-grid current
5
8
mA
Control-grid current
negligible
2
mA
0.5
0.5
A
Anode voltage
Anode current at zero signal
TH 18363
I
matched circuit assembly
For UHF-TV transmitters and translators
(Bands IV and V)
L
i
11
i
1
kW
MHz
Operating frequency ....................................................470 to 860 MHz
Dimensions ......................................................... 644 x 268 x 200 mm
Weight, approx (without tube) ..................................................... 20 kg
RF connections:
m
a type N
input .........................................................................
output .................................................................A standard 718"
Cooling ...................................................................................f o r c e air
THOMSON TUBES ELECTRONIQUES
dB
1
AM tetrode
i Output
power
1kW
in SSB, up to 110 MHz
General characteristics
Cathode ....................................................................................
oxide
Heating (1) ........................................................................................
lnterelectrodes capacitances, approx.(ground/cathode conection):
input .......................
......
..................................................75 pF
reaction ........................
.
.................................................
0.06 pF
output ..................................................................................
14.5 pF
Amplification factor, average ................... ..
.
....................4.5
Transconductance (la = 0.3 A, Vg2 = 225 V) ..........................25 mA/V
Operating position ................................................................... vertical
Weight, approx ..........................................................................
0.84 kg
Connector .............................................................................TH
16054
s e page 55
Dimensions .................................................................
for c e air
Anode cooling (2)
air flow. min ....................
.
.
.........................................
1.5 m3/mn
2 mbar
air inlet pressure, max ....................................................
outlet air temperature ...........................................................
100 "C
Electrode terminal and ceramic cooling:
type ............................................................................... forced air
temperature on the tube, max ..............................................
2 OC
.
.
I
I
Typical operation
carrier conditions
26
Maximum ratings
Anode voltage ........................................
3 kV
Control-grid voltage ............................
- 150 V
Screen-grid voltage.. ............................,400 V
Cathode current, average ......................
0.9 A
............1.5 kW
Anode dissipation .............
.
.
Control-grid dissipation ............................
1W
Screen-grid dissipation ..........................
12 W
( 1 ) Thomson Tubes Electroniques def~nesthe operating
according
each particuiar
As an
indication for equ~prnentdesign purposes only, a heater
voltage of 6 Vproduces a heatlng current of 10.5 A.
(2) Values for c o o l i n g g i v e n for maximum a n o d e
dissipation.
1
kW
30
MHz
Anode voltage
2.75
kV
Screen-grid voltage
225
Control-grid bias voltage
- 36
v
v
Anode current
700
mA
Screen-grid current
20
mA
Control-grid current
1
mA
output power
Freguency
kt THOMSON
TUBES ELECTRONIQUES
FMNHF tetrode
Output power 1
upto5.25kW
peak-of-sync in common amplification
15 kW peak-of-sync in vision carrier amplification
1
General characteristics
Cathode .................................................................thoriated tungsten
Heating (1) .........................................................................................
lnterelectrode capacitances, approx.:
cathode-control grid ...........................................................
83 pF
control grid-screen grid .................................. ..................,135 pF
screen grid-anode ..................................................................
17 pF
Amplification factor, average ......................................................... 5.5
Transconductance (la = 1.5 A, Vg2 = 500 V) ........................ 60 mAlV
Operating position ....................................................................
vertical
Weight, approx. ...........................................................................
7.5 kg
Dimensions .......................................................................
s e page 55
Anode cooling (2)................................................................ forced air
.
..........................................13 m3Imn
air flow, min. .....................
corresponding pressure drop, max. .................................... 9 mbar
OC
outlet air temperature, max. ................................................O
Electrode terminal and ceramic seal cooling
f o r c e air
type ..................................................................................
.
.
...............250 OC
temperature on the tube, max. .....................
Maximum ratings
Frequency ........................................
300 MHz
Anode voltage .........................................
7 kV
........ 6 A
Anode current ............................
.
Anode dissipation .........................
1
kW
Control-grid dissipation ..........................50 W
Screen-grid dissipation ........................150 W
( 1 ) Thomson T u i ~ e sElectron~quesdehnes the operatfng voltage according to each parficuiar s~tuatior?
As an indication for equfpment desfgn purposes only, a heater voltage of 7 V produces a heatir~gcurrent of 140 A
(2) Values /or cooiing given for maximum anode dissipahon.
Typical operation
at 224 MHz
in the matched cavity
TH 18326A
Common
amplification
Vision
only
Peak-of-sync output power
- 1 ,-JB bandwidth
5.25
9
15
9
Intermodulation products
- 54
Gain
16.5
16
dB
Anode voltage
5.4
5.6
kV
Screen-grid voltage
600
600
V
Anode current, with signal
2.4
3.2
A
Screen-grid current
20
35
mA
Control-grid current
negligible
negligible
1.8
1.2
Anode current at zero signal
TH 18326A
matched circuit assembly
1
kW
M H ~
dB
A
-
-a
l
For VHF-TV transmitters and translators
(Band III)
Operating frequency ..................................................
160 to 230 MHz
Dimensions ........................................................1361 x 391 x 256 mm
Weight, approx (without tube) ......................................................70 kg
RF connections:
input ....................................................................... femae, type N
output .............................................................A standard 1 518"
Cooling ................................................................................. forced air
THOMSON TUBES ELECTRONIQUES
1
-u-
--'
' { i
P S I
Y'
27
VHF tetrode
i Output
power
up to 21 kW
peak-of sync in common amplification
33 kW peak-of sync in vision carrier amplification
General characteristics
Cathode ................................................................ thoriated tungsten
Heating (1) .....................
direct
lnterelectrode capacitances, approx.:
..............130 pF
cathode-control grid ..........................................
.
.
...................... 21 O pF
control grid-screen grid .....................
.
screen grid-anode ................................................................ 25 pF
Amplification factor, average ...........................................................
8
Transconductance (la = 1.5 A, Vg2 = 600V) .........................140 mA/V
.
.
.
......
.... d i c a l
Operating position .........................
.Weight, approx. ............................................................................
14 kg
s e page 55
Dimensions ...................................................................
forced air
Anode cooling (2)
2
2 m3/mn
air flow, min. ....................................................
corresponding pressure drop ...................
......
............12 mbar
outlet air temperature, max. ............................ .............1 0 OC
Electrode terminal and ceramic seal cooling
o
r air
type ...................................................................................
temperature on the tube, max. ...........................................250 OC
.
.
Maximum ratings
Frequency ...................................... 300 MHz
Anode voltage ........................................ 8 kV
Anode current ....................................
10 A
Anode dissipation ............................... 8 kW
Control-grid dissipation ........................150 W
Screen-grid dissipation ........................400 W
(7) Thomson Tubes Electroniques defines the operating voltage according to each particular situation.
As an ~ndicationfor equiprnent deslgn purposes only, a heater voltage of 8 Vproduces a heating current of 180 A.
(2) Values for cooling given for maximum anode d~ssipation.
T ~ ~ i coperation
al
at 174 MHz
in the matched cavity
TH 18327A
Common
amplification
Vision
only
Peak-of-sync output power
21
33
kW
- 1 dB bandwidth
9
9
MHz
Intermodulation products
- 54
Gain
16.5
16.5
dB
6
5.9
kV
Screen-grid voltage
600
600
V
Anode current, with signal
5.4
6.3
A
Screen-grid current
85
90
mA
Control-grid current
15
25
mA
Anode current at zero signal
2
2
A
Anode voltage
TH 18327A
dB
matched circuit assembly
For VHF-TV transmitters and translators
(Band III)
Operating freq~iency....................................................170 to 230 MHz
........................... 977 x 450 x 344 mm
Dimensions ....................... .
.
.
.
.
......................80 kg
Weight, approx (without tube) ....................
RF connections:
female, type N
input ................................. ........................................
output ...............................................................
standard EIA 3 118"
Cooling.................................................................................. forced air
28
THOMSON TUBES ELECTRONIQUES
FM tetrode
i Output
power
up to 12 kW
in FM radio transmitters
General characteristics
Cathode ..................................................................
h o r i a e d tungsten
Heating (1) ................................................................direct,
dc or ac
lnterelectrode capacitances, approx.:
cathode-control grid ...............................................................
78 pF
control grid-screen grid .......................................................
115 pF
screen grid-anode ..................................................................
22 p i
Amplification factor, average ..............................................................
8
Transconductance (la = 2.5 A, Vg2 = 800 V) ........................ 55 m A N
Operating position ....................................................................vertical
Weight, approx. ...........................................................................
6.7 kg
Dimensions ..........................................................................
page 55
Anode cooling (2)...................................................................
forced air
....................................................................
air fiow,
2 m3/mn
corresponding pressure drap ..............................................
9 mbar
100 ' C
outlet air temperature, max. .................................................
Electrode terminal and ceramic seal ~ 0 0 l i n g
type .................................................................................
forced air
temperature on the tube, max. .............................................220 ' C
TYpical operation
at 110 MHz
for FM radio transmitters
Grounded-cathode
Operation
Maximum ratings
Frequency ........................................
120 MHz
Anode voltage .........................................
9 kV
Anode current ..........................................6 A
Anode dissipation .................................1 kW
Control-grid dissipation ........................100 W
Screen-grid dissipation ........................300 W
( 1 ) Tlio~iisonTubes Electroniques defines the operatrng
voltage accordirig to each partrcular situation. As an
indication for equipment design purposes only, a heater
voltage of 9.5 V produces a heaf~ngcurrent of 80 A.
( 2 ) Values for cooling g i v e n for m a x i m u m a n o d e
dissipalion.
Example 1
Example 2
15
1O
kW
300
300
Gain
23
25
kHz
dB
Anode voltage
7.5
7.5
kV
Screen-grid voltage
800
1O00
- 110
- 120
v
v
Anode current, with signal
2.3
2.35
A
Screen-grid current
200
50
150
O
mA
mA
output power
- 0 2 dB bandwidth
Control-grid bias voltage
Control-grid current
VHF tetrode
i Output
power
q.
up to 5.5 kW
peak-of-sync in common amplification
"*--
'
*
--
tif*
fd&&*.A#f&r*&&bt
.'i
0
O n«nrcum wers
L ml
L a?s
E ~
~
$4.--'
~
~
E
S
15 kW
peak-of-sync in vision carrier
amplification
General characteristics
Cathode ...............................................................
thoriated tungsten
Heating (1) ....................................................................direct, dc or ac
lnterelectrode capacitances, approx.:
cathode-control grid ...............................................................76 pF
control grid-screen grid ................................................... 122 pF
.
.
.................................22 pF
screen grid-anode ..........................
Amplification factor, average ......................................................... 8.4
Transconductance (la = 3 A, Vg2 = 800 V) .............................70 mA/V
Operating position ................................................
A i c a l
Weight, approx. .........................................................................
6 7 kg
s e page 55
Dimensions ........................................................
forced air
Anode cooling ( 2 )...............................................................
air flow, min. .................................................................. 12 m3/mn
corresponding pressure drop ...........................................
9 mbar
outlet air temperature, max. ............................................... O OC
Electrode terminal and ceramic seal cooling
type ..................................................................................
forced air
temperature on the tube, max. ........................................... 250 OC
T ~ ~ i cOperation
al
at 220 MHz
for VHF-TV
transmitters
and translators
(Band III)
30
Peak-of-çync output power
- 1 dB bandwidth
Maximum ratings
Frequency ....................................... 250 MHz
Anode voltage .................................... 5.5 kV
Anode current .............................
8A
Anode dissipation .................................
2 kW
Control-grid dissipation ........................100 W
Screen-grid dissipation ........................
250 W
............
(1) Thomson Tubes Electroniques def~nesthe operatrng
voltage according to each partrcular situation As an
ind~cabonfor equrpment design purposes only a heater
voltage of 10 V produces a heating current of 86 A
(2) Values for cooling grven for maximum anode
dissipation
Common
amplification
Vision
only
5.5
16
kW
9
7
MHz
Intermodulation products
- 54
Gain
15.5
14
dB
Anode voltage
4.7
5.2
kV
Screen-grid voltage
800
900
V
Control-grid bias voltage
- 70
- 90
V
Anode current, with signal
2.4
3.8
A
Screen-grid current
120
60
mA
Control-grid current
20
50
mA
dB
THOMSON TUBES ELECTRONIQUES
AM tetrode
i Output
power
5 kW
SSB, up to 110 MHz
General characteristics
Cathode ...................................................................
t h o r a t e tungsten
Heating (1) ................................................direct, dc or single phase
lnterelectrodes capacitances, approx. (grounded cathode):
input .....................................................................................
115 pF
..............................................................................O 4 pF
reaction
output .....................................................................................
2 pF
Maximum ratings
Amplification factor, average ............................................................
..7
Anode voltage ......................................
6.5 kV
Transconductance (la = 1.5 A, Vg2 = 600 V) .........................40 m A N
Control-grid voltage ............................
- 200 V
Operating position .....................................................................vertical'> 1-,
Screen-grid voltage ...............................
9 0V
Weight, approx ...........................................................................
-. L
Peak cathode current ..............................1O A
Dimensions ...................................................................S
page 55 Anode dissipation ...................................5 kW
Control-grid dissipation ..........................
40 W
Connecter
16121
Screen-grid
dissipation
..........................
60 W
Anode cooling (2) ~...~.....~.......................................................forced
air
air flow. min ........................................................................5 m3/mn
corresponding pressure drop ...............................................9 mbar
( 1 ) Thomson Tubes Electroniques defines the operating
voltage according to each particuiar s~tuation.As an
outlet air temperature ...........................................................
100 O C
ind~cationfor equipment design purposes only, a heater
Electrode terminai and ceramic cooling:
voltage of 6 V produces a heating current of 50 A.
type ........................................................................................
air
(2) Values for cooling g i v e n for maximum a n o d e
dissipabon.
temperature on the tube, max .............................................. 250 "C
TYpical operation
carrier conditions
output power
5
kW
Frequency
30
MHz
Anode voltage
6
kV
Screen-grid voltage
800
Control-grid bias voltage
- 110
v
v
Anode current
1.5
A
Screen-grid current
40
mA
Control-grid current
O
A
0.7
A
Anode current at zero signal
UHF tetrode
TH 382
Output power
0
1
peak-of-sync in common'amplification
11 kW
peak-of-sync in vision carrier amplification
General characteristics
Cathode ...................................................................
thoriated tungsten
Heating (1)
lnterelectrodes capacitaiices. approx.:
..............................72 p i
cathode-control grid .......................
.
.
.....................93 pF
control grid-screen grid ..........................
.
.
screen grid-anode ...............................................................13.2 pF
Amplification factor, average ............................................................ 8
Transconductance (la = 1.5 A, Vg2 = 300 V) ........................ 80 mA/V
Operating position .....................................................................vertical
Weight, approx ...............................................................................
7 kg
Dimensions .......................................................................
s e page 55
Anode cooling (2).............................................................. forced air
air flow, min ....................................................................13 m3imn
corresponding pressure drop ...........................................
8 mbar
outlet air temperature, ,pax. .................................................
100 OC
Electrode terminal and ceramic seal cooling
type ................................................................................ forced air
300 O C
temperature on the tube, rnax ..............................................
..
Maximum ratings
Frequency ......................................1000 MHz
Anode voltage ......................................
6.5 kV
Anode current ......................... ........... . A
Anode dissipation ........................
2 5 kW
Control-grid dissipation ..........................50 W
Screen-grid dissipation ........................120 W
(1) Thomson Tubes Electroniques defines the operating voltage according to each parlicular situation
As an indication for equipment design purposes oniy a heafer voltage of 4 2 V produces a heating current of 125 A
(2) Values for cooling given for maximum anode dissipation
T ~ ~ i c Operation
al
at 800 MHz
in the matched cavity
TH 18482
Peak-of-sync output power
- 1 dB bandwidth
,
I
TH 18482
Common
amplification
Vision
onlv
5.25
11
kW
12
12
MHz
Intermodulation products
- 52
Gain
15.5
15.4
dB
Anode voltage
5.5
5.5
kV
Screen-grid voltage
600
600
V
Anode current, with signal
2.7
3.25
A
Screen-grid current
30
30
mA
Control-grid current
1O
5
mA
Anode current at zero signal
1.2
1.2
A
dB
matched circuit assembly
For UHF-TV transmitters and translators
(Bands IV and V)
Operating frequency ....................................................
470 to 860 MHz
Dimensions ,..,.....,,.,,,.....................................
1 143 x 391 x 256 mm
Weight, approx (without tube) ......................................................70 kg
RF connections:
input ...................................................................... femae, type N
output .................
.................
. . . . . . . . . . . .standard EIA 1 518" or 3 118"
Cooling ................
.
.
............................................................
forced air
32
THOMSON TUBES ELECTRONIQUES
UHF tetrode
rn Output power
'------
up to 2.2 kW
peak-of-sync in common amplification
4.4 kW peak-of-sync in vision carrier amplification
2.5 kW in sound carrier amplification
)
i
i
General characteristics
Cathode ...................................................................
t h o r a e tungsten
direct
Heating (1) ...................................................................................
lnterelectrodes capacitances, approx.:
............................45 pF
cathode-control grid ...........................
control grid-screen grid ........................................................ 72 pF
screen grid-anode ................................................................
9 PF
Amplification factor, average ......................................................... 8
Transconductance (la = 1.5 A, Vg2 = 400 V) .........................80 mA/V
Operating position ................................................................... vertical
Weight, approx ..........................................................................3.6 kg
Dimensions .......................................................................s e page 55
Anode cooling (2)..................................................................f o r c e air
air flow, min ...................................................................... 8 m3lmn
corresponding pressure drop ...................................
9
mbar
outlet air temperature, max. ..........................................
0 0 "C
Electrode terminal and ceramic seal cooling
type .................................................................................f O
air
temperature on the tube, max ....................
.
..........y ..........300 "C
.
.
.
-yF?
...,J
.-
Maximum ratings
Frequency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ..looOMHz
Anode voltage .........................................
6 kV
Anode
..................................... A
Anode dissipation .........................
. 7 5 kW
ControI-grid diçsipation ..........................
25 W
Screen-grid dissipation ..........................
75 W
(1) Thomson Tubes Electroniques defines the operatrng voltage according to each particular situation.
As an indication for equrpment design purposes only, a heater voltage of 6 Vproduces a heating current of 65 A.
(2) Values for coolrng glven for maximum anode dissipation.
Common Sound
amplification only
Typical operation
at 800 MHz
in the matched cavity
TH 18665
TH 18665
Vision
only
2.5
11 5
11.5
kW
kW
MHz
16
16
16
dB
dB
Anode voltage
Screen-grid voltage
Anode current, with signal
Screen-grid current
Control-grid current
5.5
600
1.6
1O
negligible
4
500
2
30
5
5
700
1.9
15
1
- Anode current at zero signal
0.9
0.85
0.9
11.5
Intermodulation products
- 52
Gain
matched circuit assembly
For UHF-TV transmitters and translators
(Bands IV and V)
.
...................470 to 860 MHz
Operating frequency .......................
Dimensions ..........................................................
788 x 335 x 220 mm
.............45 kg
Weight, approx (without tube) ...............................
RF connections:
input ............................................................................male,
type N
output ...............................................................standard EIA 1 518"
Cooling ................................................................................
f o r c e air
.........
4.4
2.2
~eak-of-sync
output power
Sound carrier output power
-1 dB bandwidth
r
1
.&-
kV
V
A
mA
mA
A
I
1
AM tetrode
i Output
power
12 kW
in SSB, up to 120 MHz
General characteristics
Cathode .....................
.
.
..................................
h o a e tungsten
Heating (1) ...........................................
direct, dc or single phase
lnterelectrodes capacitances, approx. (grounded cathode):
input ................................................................................... 218 pF
reaction .....................
.
......................................................0.8 pF
output ..................................................................................
17 pF
Amplification factor, average ......................................................... 5.5
Transconductance (la = 2 A) ........................
.
...................O mA/V
Operating position ..................................
.
.
.
........................veriical
.
.
.............................. 7.5 kg
Weight, approx .....................................
Dimensions
s e page 55
Connector .........................................................................
TH 161 16
...................................
Anode cooling (2) .................... .
.
.
forced air
air flow, min ......................................................................
13 m3imn
corresponding pressure drop ....................................
.
.......8 mbar
.
.
.
.
. . . . . . .100 "C
outlet air temperature ..................................
Electrode terminal and ceramic cooling:
type ...........................................................................
foced air
temperature on the tube, max ........................................... 250 OC
T ~ ~ i coperation
al
carrier conditions
Maximum ratings
Anode voltage .................................
8 kV
Control-grid voltage ............................
- 200 V
Screen-grid voltage ..................
.
....... 800 V
Peak cathode current ..................
.
.........40 A
.
.
. . . .12 kW
Anode dissipation ...................
Control-grid dissipation ........................100 W
Screen-grid dissipation ........................
250 W
Anode current at zero signal ..................1.2 A
(1) Thomson Tubes Electron~quesdefines the operating
voltage according Io each particular situation As an
indication for equlpment design purposes only a heater
voltage of 7 V produces a heat~ngcurrent of 140 A
(2) Values for c o o l ~ n ggiven for maximum anode
diss~pation
output power
1O
k~
F;equency
30
MHz
Anode voltage
7.2
kV
Screen-grid voltage
600
V
- 100
V
Anode current
2.4
A
Screen-grid current
30
mA
Control-grid current
O
mA
1.2
A
Control-grid bias voltage
Anode current at zero signal
34
THOMSON TUBES ELECTRONIQUES
AM tetrode
rn Output power
50 kW
in SW and MW, up to 30 MHz
i
-*
"
>&
u
General characteristics
Cathode ...................................................................thoriated tungsten
Heating (1) ...................................................................................dire~t
Interelectrodes capacitances, approx.:
cathode-control grid .............................................................140 pF
control grid-screen grid ..........................
.
.......................265 pF
control grid-anode .................................................................1.4 pF
screen grid-anode ..................................................................
35 pF
Amplification factor, average ...........................................................4.8
Transconductance (la = 4 A, Vg2 = 800 V) ............................80 mA/V
Operating position .....................................................................vertical
Weight, approx .............................................................................13 kg
page 55
Dimensions .......................................................................see
Connector ...............................................................................
16101
Anode cooling (2) .................................................................. Vapotron
Electrode terminal cooling ..................................................... forced air
650 llmn
air flow, min. .....................................................................
air inlet pressure, max .....................................................12 mbar
Temperature on the tube, max .................................................. 150 OC
TYpical operation
Class C - Carrier conditions
Maximum ratings
Anode voltage .......................................
13 kV
Control-grid voltage ............................- 500 V
Screen-grid voltage .................................1 kV
Peak cathode current ..............................60 A
Anode dissipation ............................... 60 kW
Control-grid dissipation ...................... 300 W
Screen-grid dissipation .......................,600 W
( 1 ) Thomson Tubes Electronrques defines the operatmg
v o l t a ~ eaccordinq to each particular situation As an
jndicitlon for equ'bmeflf design PurPoses OfllY, a heater
voltage of 10 V produces a heating current of 200 A.
( 2 ) Values for cooling g i v e n for m a x i m u m a n o d e
d~ssipahon.
o u t p u t power
55
kW
Frequency
30
MHz
Anode voltage
11
kV
700
V
- 300
V
Anode current
7.5
A
Screen-grid current
150
mA
Control-grid current
400
mA
Screen-grid voltage
Control-grid bias voltage
THOMSON TUBES ELECTRONIQUES
35
UHF tetrode
i
Output power -
up to 550 W
peak-of-sync in common amplification
1 kW peak-of-sync in vision carrier amplification
1.2 k W in sound carrier amplification
General characteristics
Cathode ...................................................................
h o r i a e tungsten
Heating (1) ...................................................................................direCt
lnterelectrodes capacitances, approx.:
cathode-control grid
40 pF
control grid-screen grid .......................................................... pF
screen grid-anode .................................................................
8.2 pF
Amplification factor, average ..........................................................
7
Transconductance (la = 1.5 A, Vg2 = 400 V) .........................40 mA/V
Operating position ....................................................
veflical, anode UP
Weight, approx ............................................................................
2.1 kg .
Dimensions .......................................................................see
page 55
Anode cooling (2) .......................................................
Hypervaporo
Maximum ratings
water flow, min .....................
.
.
.
................................. 3 I/mn Frequency .................................. 0 0 0 MHz
water inlet pressure, max ........................................................
5 bar Anode voltage .........................................5 kV
outlet water temperature, less than ...................................... 80 OC Anode current ....................
.
..................2 A
Electrode terminal and ceramic seal cooling
Anode dissipation ...................................5 kW
type ..................................................................................
forced air
Control-grid dissipation ............................
5W
..............................................
temperature on the tube, man
250 OC Screen-grid dissipation ..........................25 W
(1) Thomson Tubes Electroniques defines the operating voltage according to each particular situation.
As an ~ndicationfor equipment design purposes only, a heater voltage of 5.8 V produces a heating current of 34 A.
(2) Values for cooling given for maximum anode dissipation.
Sound only
amplification
T y ~ i c aoperation
l
at 850 MHz
in the matched cavity
'
TH 8563
carrier output power
1.2
kW
- 1 dB bandwidth
10
MHz
15.5
d~
4
kV
Gain
Anode voltage
Screen-grid voltage
Anode current, with signal
Screen-grid current
Control-gridcurrent
Anode current at zero signal
TH 18563
A
0.5
matched circuit assembly
For UHF-TV transmitters and translators
(Bands IV and V)
. .
negligible
"*pg
i
:%
2
Operating frequency .................................................. 470 to 860 MHz
670 x 268 x 174 mm
Dimensions ..........................................................
Weight, approx (without tube) ...................................................... 17 kg
RF connections:
input ....................................................................... f e m a e type N
output ............................................................
standard EIA 718"
Cooling .............................................. Hypervapotron and forced air
36
THOMSON TUBES ELECTRONIQUES
AM tetrode
TH 532
Output power
60 kW
in SW and MW, up to 30 MHz
General characteristics
Cathode ................................................................... t h o r a t e tungsten
Heating (1) ....................................................direct, dc or single phase
lnterelectrodes capacitances, approx.:
cathode-control grid .............................................................
140 pF
control grid-screen grid .....................................................265 pF
control grid-anode ....................
.
.........................................
1.4 pF
screen grid-anode ................................................................35 pF
Amplification factor, average ......................................................... 4.8
80 mA/V
Transconductance (la = 4 A) ................................................
Operating position .............................................v e c a anode up
Weight, approx ............................................................................. 17 kg
Dimensions ...................................................................... s e page 55
Connector ........................................................................... T H 16118
Anode cooling (2) ......................................................... Hypervapotron
water flow, min ......................................................................... 25 I/mn
water inlet pressure, max ........................................................
5 bar
outlet water temperature, less than ..................................... 80 O C
Electrode terminal and ceramic cooling:
type ................................................................................. f o r c e air
temperature on the tube, max ..............................................200 "C
T ~ ~ i coperation
al
carrier conditions
Maximum ratings
Anode voltage .......................................
12 k V
Control-grid voltage ....................
-....
500 V
Screen-grid voltage ............................. 900 V
Peak cathode current ............................ 70 A
Anode dissipation ............................... 6 kW
Control-grid dissipation ........................300 W
Screen-grid dissipation .......................,600 W
( 1 ) Thomson Tubes Electroniques defines the operating
voltage according to each particular situation As an
ind~cationfor equipment design purposes only a heater
voltage of 10 V produces a heating current of 200 A
(2) Values for cooling g l v e n for m a x i m u m a n o d e
d~ssipaoon
output power
55
k~
Frequency
30
MHz
- 300
V
Anode current
7.5
A
Screen-grid current
150
mA
Control-grid current
350
A
Anode voltage
Screen-grid voltage
Control-grid bias voltage
1
J1
t> THOMSON TUBES ELECTRONIQUES
B
TH 532
AM tetrode
Output power
60 kW
in SW and MW, up to 30 MHz
General characteristics
Cathode ......................................................................... tungsten
Heatinq
- .(1)
. ...................................................direct dc or single phase
lnterelectrodes capacitances, approx.:
cathode-control grid .......................................................pF
control grid-screen grid ................................................... ...265 PF
control grid-anode ...............................................................
1.4 pF
screen grid-anode ..-..., .. ............................................ 35 pF Maximum ratings
Anode voltage .......................................
12 kV
Amplification factor, average ......................................... 4
8
Control-grid voltage ............................ 500 V
Transconductance (la = 4 A) .............................................O mNV
...............................900 V
Operating position ...................................................vertica 1. anode up Screen-grid voltage
Peak cathode current ..............................70 A
Weight, approx ..........................................................................1 kg
Anode dissipation ............................... 60 kW
Dimensions ........................................................................
page 55
dissipation ........................300 W
Connecter ...........................................................................161 18 Control-grid
Screen-grid dissipation ........................600 W
Anode cooling (2) .........................................................Hypewapotron
water flow, min ..........................................................................25 Ilmn
5 bar
( 7 ) Thomson Tubes Electroniques defines the operahng
water iniet pressure, max ........................................................
voltage accord~ngto each particular situation As an
outlet water temperature, less than .......................................
8 "C
indication for equipment design purposes only, a heater
Electrode terminal and ceramic ~00ling:
voltage of 10 V produces a heating current of 200 A
(2) Values for c o o l i n g g i v e n for m a x i m u m a n o d e
type . ...............................................................................
forced air
diss~pation
temperature on the tube, max .............................................. 200 OC
-
Typical operation
carrier conditions
o u t p u t power
55
kW
Frequency
30
MHz
Anbde voltage
11
kV
700
- 300
v
v
Anode current
7.5
A
Screen-grid current
150
Control-grid current
350
mA
A
Screen-grid
voltage
Control-grid bias voltage
AM tetrode
Output power
350 kW
in LW and MW,
300 kW
in SW,up to 50 MHz
General characteristics
Cathode ...................................................................
horated tungsten
Heating (1) ..............................................
direct, dc or single phase
lnterelectrodes capacitances, approx.:
cathode-control grid .......................................................... O pF
control grid-screen grid ................................................... 510 pF
control grid-anode ......................................................
.
.
.....4.5 pF
screen grid-anode ................................................................ 74 pF
............................. 4.3
Amplification factor, average ....................
.
.
.
Transconductance (la = 25 A, Vg2 = 1000 V) ......................400 mNV
Operating position ......................................
, l ac . .
anode up
Weight, approx ........................................................................... 56 kg
Dimensions ...................................................................
s e page 55
Connector ...............
.
..................................................... TH 16108A
Anode cooling (2) .....................................................
Hypewapotron
water flow, min ...............................................................
150 I/mn
water inlet pressure, max .................................................... 5 bar
80 "C
outlet water temperature, less than ..................................
Electrode terminal and ceramic cooling:
type ..................................................................................
forced air
200 OC
temperature on the tube, max ..........................................
T y ~ i c aoperation
l
carrier conditions
Maximum ratings
Anode voltage .......................................
15 kV
Control-grid voltage ............................- 800 V
Screen-grid voltage .......................... 1200 V
Peak cathode current ............................400 A
Anode dissipation ............................. 300 kW
Control-grid dissipation ..........................2 kW
Screen-grid dissipation ..........................5 kW
(1) Thomson Tubes Electroniques defines the operating
voltage according to each parlicular situation. As an
indication for equipmenl design purposes only. a healer
voltage of 18 V produces a heating current of 430 A.
(2) Values for cooling given for maximum anode
dissipation.
output power
300
kW
Frequency
30
MHz
Anode voltage
14
kV
1O00
V
1
A
Screen-grid voltage
Control-grid bias voltage
Anode current
Screen-grid current
Control-grid current
38
,,\ M O M S O N TUBES ELECTRONIQUES
AM tetrode
Output power
1.25 MW
in LW and MW
General characteristics
Cathode ................................................................. thoriated tungsten
Heating (1) ...................................................direct, dc or single phase
lnterelectrodes capacitances, approx.:
cathode-control grid .............................................................830 pF
control grid-screen grid .................................................... 1600 pF
.
............................ 15.5 pF
control grid-anode ...............................
screen grid-anode ................................................................220 pF
Amplification factor, average ....................
.
......................................5
Transconductance (la = 35 A, Vg2 = 1000 V) ..................... ,600 m A N
Operating position ..............................................v e i c a anode up
Weight, approx ........................................................................... 155 kg
Dimensions ...................................................................... s e page 55
Connector ..............................................................................
16114
Anode cooling (2) ......................................................... Hypewapotron
water flow, min ..........................................................
40O I/mn
water inlet pressiire, max .......................................................5 bar
outlet water temperature, less than ..................................... 80 OC
Electrode terminal and ceramic cooling:
type ..................................................................................
f o r c e air
temperature on the tube, max ..............................................200 "C
TYpical operation
carrier conditions
( 1 ) Thomson Tubes Electroniques defines the operabng
voilage according !O each parficular situation As an
indication for equipmenf design purposes only a heater
voltage of 30 V produces a heating current of 900 A
(2) Values for cooling g i v e n for m a x i m u m a n o d e
dissipation
output power
1000
k~
2
MHz
Anode voltage
13.0
kV
Screen-grid voltage
1100
V
Control-grid bias voltage
- 550
V
85
A
Screen-grid current
8
A
Control-grid current
7
A
Frequency
Anode current
Lt THOMSON TUBES ELECTRONIQUES
Maximum ratings
Anode voltage ..................................... 15 kV
Control-grid voltage ............................- 800 V
Screen-grid voltage .............................1250 V
Peak cathode current ........................ 1300 A
Anode dissipation ............................... 1 MW
Control-grid dissipation ..........................6 kW
Screen-grid dissipation ........................16 kW
39
UHF tetrode
i Output power
up to 1.1 kW
peak-of-sync in common amplification
General characteristics
Cathode .................................................................
t h o r i a e tungsten
Heating (1) .........................................................................................
lnterelectrodes capacitances, approx.:
cathode-control grid ...............................................................
40 pF
control grid-screen grid ..........................................................5 PF
screen grid-anode ................................................................. 8.2 pF
Amplification factor, average ............................................................
7
Transconductance (la = 1.5 A, Vg2 = 500 V) ..........................40 mA/V
Operating position ................................................... v e i c a anode up
Weight, approx ............................................................................
2.1 kg
Dimensions .....................................................................See
page 55
.
.
.
.
............................
Hypervapotron
Anode cooling (2) ...................
Maximum ratings
water flow, min ......................................................................
3 I/mn Frequency ......................................
1000 MHz
............................... 5 bar Anode voltage .....................................
water iniet pressure, rnax ................
5 kV
............. 80 OC Anode current .........................
outlet water temperature, less than .....................
.
.............2 A
.
Electrode terminal and ceramic seal cooling
...........‘.....5 kW
Anode dissipation ..........
.
.................................................
forced air Control-grid dissipation ............................5 W
type ........................
Screen-grid dissipation ..........................25 W
ternperature on the tube, rnax ............................ . . . . . . . . . .250 OC
.
.
.
.
.
.
.
(1) Thomson Tubes Electroniques defines the operating voltage according to each parîicular situation.
As an indication for equipment design purposes only, a heater voltage of 6 V produces a heating current of 34 A
(2) Values for cooling g~venfor maximum anode dissipalion.
TYpical operation
at 850 MHz
in the matched cavity
TH 18563
Common
amplification
Vision
only
Peak-of-çync output power
1.1
2.2
kW
- 1 dB bandwidth
1O
1O
MHz
Intermodulation products
- 54
Gain
15.5
15.5
dB
0.8
1.5
A
Screen-grid current
5
8
mA
Control-grid current
negligible
2
mA
0.5
0.5
A
dB
Anode voltage
Screen-grid voltage
Anode current, with signal
Anode current at zero signal
TH 18563
matched circuit assembly
For UHF-TV transmitters and translators
(Bands IV and V)
470 to 860 MHz
Operating frequency ....................................................
Dimensions ........................................................ 670 x 268 x 174 mm
Weight, approx (without tube) .................................................... 17 kg
RF connections:
input ........................................................................f e m a e type N
output ................................................................ standard EIA 718"
Cooling ................................................. Hypervapotron and forced air
40
,,\ MOMSON TUBES
ELECTRONIQUES
Output power
250 kW
in LW and MW,
200 kW
in SW, up to 50 MHz
General characteristics
Cathode ...................................................................
thoriated tungsten
Heating (1)..................................................direct,
dc or single phase
lnterelectrodes capacitances, approx.:
cathode-control grid ....................................................... 3
0 pF
control grid-screen grid ........................................................440 pF
control grid-anode ....................................................................4 pF
screen grid-anode ........................................................6
2 PF
Amplification factor, average ......................................................
4.8
Transconductance (la = 15 A, Vg2 = 1000 V) ......................220 rWW
Operating position .................................................. veflical, anode up
Weight, approx .........................................................................38 kg
Dimensions ....................................................................
page 55
Connecter ...........................................................
161 10
Anode cooling (2) .........................................................Hypervapotron
water flow, min ..................................................................110 Ilmn
Maximum ratings
Anode voltage .......................................
15 kV
- 800 V
Control-grid voltage ............................
Screen-grid voltage ..............................1 2 kV
Peak cathode current ............................300 A
Anode dissipation ...............................
250 k~
Control-grid dissipation .......................1.5 kW
Screen-grid
.......................... kW
water inlet pressure, max ........................................................5 bar
outlet water tWnperat~re,less than .......................................8 OC
Electrode terminal and ceramic ~00ling:
..................................................................................O
air
type
temperature on the tube, max ..............................................200 OC
Typical operation
carrier conditions
(,, Tho,son
Electroniques defines the operahng
voltage accord~ngto each parficular s~tuation.As an
~ndicationfor equipment design purposes only, a heater
voltage of 15 Vproduces a heating current of 320 A.
(2) Values for cooling given for maximum a n o d e
dissipation.
output power
200
kW
Frequency
30
MHz
Anode voltage
14
kV
Screen-grid voltage
1O00
v
Control-grid bias voltage
- 550
v
Anode current
17
A
Screen-grid current
0.9
0.9
A
Control-grid current
A
AM tetrode
Output power
650 kW
in LW and MW,
550 kW
in SW, up to 50 MHz
General characteristics
Cathode ...................................................................
thoriated tungsten
direct, dc or single phase
Heating (1) ................................................
lnterelectrodes capacitances, approx.:
cathode-control grid ........................................................... 445 pF
control grid-screen grid ...................................................... 750 pF
control grid-anode .................................................................
6.3 pF
screen grid-anode .............................................................. 100 pF
Amplification factor, average ...................
.............................4.4
Transconductance (la = 35 A, Vg2 = 1000 V) ......................500 mA/V
Operating position ...................
......
.................
v e i c a anode up
Weight, approx ........................................................................... 74 kg
s e page 55
Dimensions
Connector ............................................................................
16124
Anode cooling (2) ...............................
.
......................Hypewapotron
water flow, min
20 I/mn
water inlet pressure, max ...................................................... 5 bar
outlet water temperature, less than ...................................... 80 OC
Electrode terminal and ceramic cooling:
type ............................ . . . ..............................................
forced air
temperature on the tube, max ................... .............. . .O OC
.
.
.
.
.......................................................................
................................................................
.
.
TYpical operation
carrier conditions
Maximum ratings
Anode voltage ..................................... 15 kV
Control-grid voltage .......................... - 800 V
Screen-grid voltage .......................... 1.25 kV
Peak cathode current ............................
600 A
Anode dissipation ...............
.
.
........ O 0 kW
Control-grid dissipation ..........................3 kW
Screen-grid dissipation ..........................8 kW
( 1 ) Thomson Tubes Electroniques defines the operating
voltage according to each particular situation, As an
indication for equipment design purposes only, a heater
voltage of 23 Vproduces a heating cuvent of 500 A.
( 2 ) Values for c o o l ~ n ggiven for maximum anode
dissipation.
output power
550
kW
Frequency
30
MHz
Anode voltage
14
kV
Screen-grid voltage
1O00
V
Control-grid bias voltage
- 550
V
Anode current
47
A
Screen-grid current
4.2
A
Control-grid current
4
A
M O M S O N TUBES ELECTRONIQUES
VHF tetrode
i Output power
up to 10.5 kW
peak-of-sync in common amplification
15 kW
peak-of-sync in vision carrier amplification
General characteristics
Cathode .................................................................. t h o r a t e tungsten
Heating (1) ...................................................................................direct
lnterelectrodes capacitances, approx.:
cathode-control urid
- ............................................................... 83 DF
control grid-screen grid .................................................... 135 pF
screen grid-anode ..................................................................
17 pF
Amplification factor, average ......................................................... 5.5
Transconductance (la = 2 A, Vg2 = 500 V) ....................
.
.....60 m A N
Operating position ......................................d i c a l , anode up
Weight, approx ............................................................................
4.4 kg
Dimensions ......................................................................s e page 55
Hypervapotron
Anode cooling (2) ......................................................
water flow, min ....................................................................12 I/mn
water inlet pressure, max ...................................................5 bar
outlet water temperature, less than ..................................... 80 O C
Electrode terminal and ceramic seal cooling
type ................................................................................
f o r c e air
temperature on the tube, max ...........................................250 OC
Maximum ratings
Frequency ................................
300 MHz
Anode voltage .........................................7 kV
Anode current ....................................... A
Anode dissipation .............................20 kW
Control-grid dissipation ..........................50 W
Screen-grid dissipation ........................150 W
(1) Thomson Tubes Electroniques defines the operating voltage according to each parficular situation.
As an indication for equipment design purposes only, a heater voltage of 7 V produces a heabng current of 140 A
(2) Values for cooling given for maximum anode dissipation.
T~~ical
at 174MHz
in the matched cavity
TH 18526
Peak-of-sync output power
- 1 dB bandwidth
Intermodulation products
Vision
only
10.5
15
kW
9
9
MHz
- 50
dB
Gain
16
16
dB
Anode voltage
5.5
5.5
kV
Screen-grid voltage
600
600
V
Anode current, with signal
3.1
3.2
A
Screen-grid current
30
35
mA
Control-grid current
3
negligible
mA
1.2
1.2
A
Anode current at zero signal
TH 18526A
Common
amplification
matched circuit assembly
For VHF-TV transmitters and translators
(Band III)
Operating frequency .................................................... 170 to 230 MHz
Dimensions ........................................................1430 x 420 x 266 mm
Weight, approx (without tube) .................................................... 70 kg
RF connections:
input ......................................................................... f e m a e type N
output ............................................................... standard EIA 3 118"
Cooling .......................................
nor topa.
and forced air
THOMSON TUBES ELECTRONIQUES
43
AM tetrode
Output power
12 kW
in SW, up to 300 MHz
General characteristics
Cathode ................................................................. thoated tungsten
Heating (1) .................................................direct, dc or single phase
lnterelectrodes capacitances, approx.:
cathode-control grid ............................................................
83 pF
control grid-screen grid ....................
..................................3 5 pF
control grid-anode ...........................
.
..................................0.8 pF
screen grid-anode ..................................................................
17 pF
Amplification factor, average .............................. .
.
.....................5.5
Transconductance (la = 1.5 A, Vg2 = 500 V) .........................60 m A N
Operating position ...............................................................
vertical
Weight, approx ............................................................................4.4 kg
Dimensions .......................................................................s e page 55
Connector ........................................................................... TH 16132
Anode cooling (2) ......................................L a p o t r o n
water flow, min .................................................................... 8 Ilrnn
water inlet pressure, rnax ......................................................
5 bar
outlet water temperature, less than .......................................80 OC
Electrode terminal and ceramic cooling:
forced air
type ...........................................................................
temperature on the tube, max ......................................... .....250O C
TyPical operation
carrier conditions
Maximum ratings
Anode dc voltage ....................................8 kV
Control-gnd voltage ............................- 200 V
Screen-grid voltage ...............................800 V
Peak cathode current .............................. 30 A
Anode dissipation ..............................20 kW
Control-grid dissipation ........................100 W
Screen-grid dissipation ........................250 W
(7) Thomson Tubes Electroniques def~nesthe operating
voltage according to each particular situation. As an
indicar~onfor equlpment design purposes only, a heater
voltage of 7 Vproduces a heating current of 140 A.
(2) Values for cooling given for maximum anode
dissipation.
output power
12
k~
Frequency
30
MHz
Anode voltage
7.5
kV
Screen-grid voltage
600
V
- 145
V
Anode current
2.3
A
Screen-grid current
1O 0
mA
Control-grid current
1O
mA
Control-grid bias voltage
THOMSON TUBES ELECTRONIQUES
AM tetrode
i Output
power
12 kW
up to 120 MHz
General characteristics
Cathode ................................................................... t h o r i a e tungsten
dc or single phase
Heating (1) ..............................................direct
lnterelectrodes capacitances, approx.:
cathode-control grid ............................................................72 pF
control qrid-screen
grid ........................................................ 92 pF
control grid-anode ...............................................................
..0.8 pF
screen grid-anode ..................................................................
6 pF
Amplification factor, average ..........................................................
.5.5
60 m N V
Transconductance (la = 2 A, Vg2 = 500 V) ............................
Operating position ...................................................v e i c a anode up
Weight, approx ................................................ .................4.4 kg
Dimensions ..........................................................................
page 55
Anode cooling (2) ......................................................... Hypewapotron
water flow, min ......................................................................
8 I/mn
water inlet pressure, max ............................... .
.
. . . . . . . . . . . . . 5. bar
..............80 ' C
outlet water temperature, less than .....................
.
Electrode terminal and ceramic cooling:
type ..................................................................................
forced air
temperature on the tube, max ............................................ 250 OC
Typical operation
carrier conditions
Maximum ratings
Anode voltage ....................................8
kV
Control-grid voltage ...................
-.....
200 V
Screen-grid voltage ...............................
800 V
Peak cathode current ..............................
40 A
Anode dissipation ..........
.
.
............20 kW
Control-grid dissipation ........................100 W
Screen-grid dissipation ...................... 250 W
( 1 ) Thomson Tubes Electroniques dehnes the operahng
voitage accord~ngto eacli particuiar situation As an
indication for equipment design purposes only a heater
voilage of 7 V praduces a heating current of 140 A
( 2 ) Values for cooiing grven for maxrrnurn anode
dissipation
output power
12
kW
Frequency
30
MHz
Anode voltage
7.5
kV
Screen-grid voltage
500
V
Control-grid bias voltage
- 110
V
Anode current
2.3
A
Screen-grid current
1O0
mA
Control-grid current
10
mA
UHF tetrode
i Output
power
up to 31.5 kW
peak-of-sync in common amplification
44 kW
peak-of-sync in vision carrier amplification
General characteristics
Cathode ...................................................................
t h r a e d tungsten
Heatina
(1) .........................................................................................
.
lnterelectrodes capacitances, approx.:
cathode-control grid ...............................................................
92 pF
control grid-screen grid ........................................................
148 pF
screen grid-anode ..................................................................
18 pF
Amplification factor, average ..........................................................
.5.5
Transconductance (la = 4 A, Vg2 = 600 V) .......................... 100 m N V
Operating position ....................................................verticalanode up
Weight, approx ..........................................................................
..6.5 kg
Dimensions ......................................................................... page 55
Anode c001ing (2)..........................................................
Hypervapotron
water flow, min ....................................................................
50 limn
5 bar
water inlet pressure, max ........................................................
80 OC
outlet water temperature, less than .......................................
Screen grid terminal cooling ........................................................
water
water flow, min ......................................................................
2 I/mn
Eiectrode terminal and ceramic seal cooling
type ..................................................................................
forced air
temperature on the tube, max ............................................ 300 OC
.,\
f
Maximum ratings
Frequency ......................................1000 MHz
Anode voltage .........................................9 kV
Anode current ...........................................9 A
Anode dissipation .................................
42 kW
Control-grid dissipation ..........................80 W
Screen-grid dissipation ........................200 W
(1) Thomson Tubes Electroniques defines the operating voltage accord~ngto each particular situation
As an ~ndicationfor equiprnent design purposes only, a heater voltage of 5 2 Vproduces a heating current of 210 A
(2) Values for cooling given for maximum anode dissipation
T Y P ~ operation
c~~
at 700 MHz
in the matched cavity
TH 18550
TH 18550
Common
amplification
Vision
only
Peak-of-sync output power
- 1 dB bandwidth
31.5
12
44
kW
12
MHz
Intermodulation products
- 48
Gain
14.5
14.7
dB
Anode voltage
8.5
9
kV
Screen-grid voltage
800
800
V
Control-grid bias voltage
- 113
- 114
v
Anode current, with slgnal
6.45
Screen-grid current
130
6.75
70
mA
Control-grid current
150
90
mA
d6
A
matched circuit assembly
For UHF-TV transmitters and translators
(Bands IV and V)
460 to 860 MHz
Operating frequency
1
8
3
Dimensions ........................................................ x 349 x 353 mm
Weight, approx (without tube) ......................................................70 kg
RF connections:
f e m a e type LC or 7116
input ...........................................................
output ...............................................................
standard EIA 3 118"
Cooling ...................................................
Hypewapotron and forced air
46
1,\ THOMSON
TUBES ELECTRONIQUES
I
I
I
I
VHF tetrode
i Output power
up to 21 kW
peak-of-sync in common amplification
41 kW
peak-of-sync in vision carrier amplification
General characteristics
Cathode ...............................................................
thoriate tungsten
direct, dc or single phase
Heating (1) ..............................................
lnterelectrodes capacitances, approx.:
cathode-control grid .............................................................
130 pF
control grid-screen grid ..................................................... 21 O pF
screen grid-anode ..................................................................
25 pF
Amplification factor, average ............................................................ 8
Transconductance (la = 5 A, Vg2 = 600 V) ...........................140 m A N
Operating position ...................................................v e i c a anode up
Weight, approx .......................................................................... 7.5 kg
Dimensions ....................................................................... s e page 55
Anode cooling (2) ..........................,..............................Hypervapotron
water flow, min ....................................................................8 Ilmn
water inlet pressure, max ........................... .
.
.....................5 bar
outlet water temperature, less than ...............................
.
....80 "C
Electrode terminal and ceramic seal cooling
type ................................................................................
f o r c e air
250 OC
temperature on the tube, max ..............................................
Maximum ratings
Frequency .............
.
......................
300 MHz
Anode voltage ........................................ 8 kV
Anode current .........................................
1O A
Anode dissipation ............................... 50 kW
Control-grid dissipation ........................150 W
Screen-grid dissipation ........................400 W
(1) Thomson Tubes Electroniques dehnes the operating voltage according to each parlicular situation
As an indicallon for equipment design purposes only, a heater voltage of 8 V produces a heahng current of 185 A
(2) Values for cool~nggiven for maximum anode dissipation
T ~ ~ i coperation
al
at 174 MHz
in the matched cavity
TH 18527A
Peak-of-sync output power
- 1 dB bandwidth
Vision
only
21
41
kW
9
8.5
MHz
Intermodulation products
- 54
Gain
16.5
17
dB
6
7.3
kV
Screen-grid voltage
600
600
V
Anode current, with signal
5.4
5.9
A
Screen-grid current
85
120
mA
Control-grid current
15
10
mA
Anode current at zero signal
2
2
A
Anode voltage
TH 18527A
Common
amplification
dB
matched circuit assembly
For VHF-TV transmitters and translators
(Band III)
I
1
Operating frequency ....................................................170 to 230 MHz
Dimensions ........................................................1053 x 479 x 330 mm
Weight, approx (without tube) .....................................................90 kg
RF connections:
femae, type N
input .....................................................................
output ............................................................... standard EIA 3 118"
Cooling ................................................... Hypeapotron and forced air
THOMSON TUBES ELECTRONIQUES
1
1
47
I
1
AM tetrode
i Output
--
power
350 kW
in LW and MW,
300 kW
in SW, up to 50 MHz
General characteristics
Cathode ...................................................................
h o r a t e d tungsten
d r e c dc or single phase
Heating ( 1 ) ....................................................
lnterelectrodes capacitances, approx.:
cathode-control grid .............................................................
5 pF
control grid-screen grid ........................................................
610 pF
control grid-anode .................................................................
4.7 pF
,........85 pF
screen grid-anode .........................................................
Amplification factor, average ...........................................................
4.3
Transconductance (la = 25 A, Vg2 = 1000 V) ......................400 mAlV
Operating position ....................................................vertical,
anode up
Weight, approx .............................................................................
60 kg
page 55
Dimensions .......................................................................see
Connecter ...............................................................................
16124
Anode cooling (2) .........................................................
Hypervapotron
water flow, min .................................................................
150 Ilmn
5 bar
water inlet pressure, max ........................................................
outlet water temperature, less than .......................................8 OC
Electrode terminal and ceramic cooling:
type ..................................................................................
forced air
temperature on the tube, max ............................................ 200 O C
TYpical operation
carrier conditions
Maximum ratings
Anode voltage .......................................
15 kV
Control-grid voltage ............................- 800 V
Screen-grid voltage ..............................1 .2 kV
Peak cathode current ............................400 A
Anode dissipation .......... . . . . . . . . . . . O
kW
Control-grid dissipation ..........................
2 kW
Screen-grid dissipation ..........................5 kW
( 1 ) Thomson Tubes Eleclroniques defines the operaling
voltage according to each parficular siluation As an
ind~cationfor equipment design purposes only a heater
voltage of 15 V produces a heating currenl of 500 A
(2) Values for c o o l ~ n gg i v e n for m a x i m u m a n o d e
d~ssipation
output power
300
kW
Frequency
30
MHz
Anode voltage
14
kV
Screen-grid voltage
1O00
Control-grid bias voltage
- 550
v
v
Anode current
25
A
Screen-grid current
1.5
A
Control-grid current
1
A
1,\ THOMSON TUBES ELECTRONIQUES
TH 576
AM tetrode
i Output
power
550 kW
in SW, up to 50 MHz
General characteristics
Cathode ...................................................................t h o r i a e t u n g ~ t e n
Heating (1) ..................................................direct,
dc or single phase
Interelectrodes capacitances, approx.:
cathode-control grid .............................................................
687 pF
control grid-screen grid ........................................................
814 pF
control grid-anode ............................................................... 10 pF
screen grid-anode ................................................................
142 pF
Amplification factor, average ....................
.
................................... 5
600 mA/V
Transconductance (la = 35 A, Vg2 = 1000 V) ......................
Operating position .............................
............ v e c a anode up
Weight, approx ...........................................................................
110 kg
Dimensions ................................................................
page 55
Connecter ...............................................................................
16138
Anode cooling (2) .........................................................Hypewapotron
water flow, min ...............................................................
300 llmn
5 bar
water inlet pressure, max ........................................................
.......... 80 ' C
outlet water temperature, less than ...................
Electrode terminal and ceramic cooling:
..................................................
type .......................
.
.
foced air
O "C
temperature on the tube, max ...........................................
.
.
.
.
.
T Y P ~ operation
c~~
carrier conditions
Maximum ratings
Anode voltage ......................................
.15 kV
Control-grid voltage ..........................- 1000 V
Screen-grid voltage ....................
.......
2 kV
Peak cathode current ..............
.
.........650 A
.
...........800 kW
Anode dissipation ................
Control-yrid dissipation ..........................4 kW
Screen-grid dissipation ........................
12 kW
( 1 ) Thomsoi? Tubes Eiectro~iiquesdefines the operahng
voltage according Io each paiticular situatfon As an
indication for equipment design purposes only a heater
voltage of 19 V produces a heating currenl of 1000 A
( 2 ) Values for c o o l f n g g l v e n f o r m a x i m u m a n o d e
dissipation
output power
550
kW
Frequency
30
MHz
Anode voltage
15
kV
Screen-grid voltage
1200
V
Control-grid bias voltage
- 800
V
Anode current
39
A
Screen-grid current
7
A
Control-grid current
2
A
ANI tetrode
i Output
7
power
125 kW
in MW and SW, up to 50 MHz
General characteristics
Cathode ...................................................................
thoriated tungsten
direct, dc or single phase
Heating (1) ...................................................
lnterelectrodes capacitances, approx.:
cathode-control grid .............................................................
180 pF
control grid-~creengrid ........................................................
310 pF
control grid-anode .................................................................
2.3 p i
screen grid-anode ..................................................................
47 PF Maximum ratings
Amplification factor, average ..............................................................
5 Anode voltage .......................................15 kV
Control-grid voltage ............................- 800 V
Transconductance (la = 25 A, Vg2 = 1000 V) ......................140 mA/V
..............................1.2kV
Operating position ....................................................
veflical, anode up Screen-grid voltage
............................160 A
Peak
cathode
current
.............................................................................
Weight, approx
35 kg
...............................
Anode
dissipation
150 kW
Dimensions ......................................................................S
page 55
Control-grid dissipation .......................0.8 kW
Connecter ..........................................................................TH
16111
Screen-grid dissipation ..........................2 kW
Anode cooling (2) .........................................................
Hypervapotron
water flow, min ....................................................................
70 I/mn
5 bar
(1) Thomson Tubes Electroniques defines the operatlng
water inlet pressure, max .......................................................
voltage according Io each particular situation As an
outlet water temperature, less than .......................................
8 "C
indication for equipment design purposes only a lieater
voltage of 10 V produces a heating current of 280 A
Electrode terminal and ceramic ~00ling:
type ..........................................................................
.....forced
air
(2) Values for cooling g i v e n for maxlrnum anode
dissipabon
200 OC
temperature on the tube, max ..............................................
Typical operation
carrier conditions
1
50
o u t p u t power
125
kW
Frequency
30
MHz
Anode voltage
14
kV
Screen-grid voltage
1O00
Control-grid bias voltage
- 550
v
v
Anode current
10.5
A
Screen-grid current
0.8
A
Control-grid current
0.9
A
lHOMSON TUBES ELECTRONIQUES
UHF tetrode
i Output power
up to 22 kW
peak-of-sync in common amplification
10.5 kW
peak-of-sync in common amplification
General characteristics
Cathode ...............................................................
thorated tungsten
Heating (1) .............................................
direct dc or single phase
Interelectrodes capacitances, approx.:
cathode-control grid ...............................................................
72 pF
control grid-screen grid ..........................................................
93 pF
screen grid-anode ............................................................. 13.2 pF
Amplification factor, average .........................................................8
Transconductance (la = 2 A, Vg2 = 300 V) ............................80 m A N
Operating position .................................................... v e i c a anode up
..................................................4 1 kg
Weight, approx ................ .
.
Dimensions .......................................................................s e page 55
Anode cooling (2) ..........................................................
Hypervapotron
water flow, min ................................................................. 15 I/mn
water inlet pressure, max .....................
.
...............................5 bar
outlet water temperature ...................................................... 80 "C
Screen grid terminal cooling ........................................................
water
water flow, min .............................................................. 1.5 l/mn
Electrode terminal and ceramic seal cooling
type ............................................................................... f o r c e air
temperature on the tube, max ..............................................300 OC
..
Maximum ratings
Frequency ......................................
1000 MHz
7.5 kV
Anode voltage ......................................
Anode current ................................
....
A
Anode dissipation .................
.
.........25 kW
Control-grid dissipation ..........................50 W
Screen-grid dissipation ........................ 120 W
( 1 ) Thomson Tubes Electron~quesdef~nesthe operating voltage according to each parf~cularsftuatlon
As an indication for equlpment deslgn purposes only, a heater voltage of 4 2 V produces a heating current of 146 A
(2) Values for cooling given for maximum anode dissipation
T ~ ~ i coperation
al
at 700 MHz
in the matched cavity
TH 18582
Common
amplification
Vision
only
Peak-of-sync output power
10.5
22
kW
-
12.5
12.5
MHz
1 d B bandwidth
- 48
lntermodulation products
dB
Gain
15
15.1
dB
Anode voltage
5.5
7.3
kV
Screen-grid voltage
600
800
V
Anode current, with signal
3.45
4.3
A
1.5
1.6
A
Screen-grid current
Control-grid current
,
Anode current at zero signal
I
I
I
I
I
I i
TH 18582
matched circuit assembly
For UHF-TV transmitters and translators
(Bands IV and V)
Operating frequency .................................................478 to 860 MHz
Dimensions .......................................................1092 x 322 x 285 mm
Weight, approx (without tube) ................................................
70 kg
RF connections.
input .....................................................femae type N, LC or 7/16"
output ....................................standard EIA 3 118" rigid coaxial line
Cooling ................................................... Hypeapotron and forced air
1
I
ri,
UHF tetrode
Output power
up to 2.2 kW
peak-of-sync in common amplification
4.4 kW peak-of-sync in vision carrier amplification
2.5 kW in sound carrier amplification
General characteristics
Cathode ...................................................................
thoriated tUngSten
Heating ( 1 ) .........................................................................................
lnterelectrodes capacitances, approx.:
cathode-control grid ...............................................................
5 pF
control grid-screen grid .........................................................
72 pF
screen grid-anode ....................................................................
9 PF
........................... 8
Amplification factor, average ...................
60 mAiV
Transconductance (la = 2 A, Vg2 = 300 V) .........................
Operating position ...........................................v e i c a anode up
Weight, approx ............................................................................
2 9 kg
Dimensions ..........................................................................
page 55
Anode cooling (2) ..........................................................Hypervapotron
water flow, min ................................................................... 6 Ilrnn
water inlet pressure, max ................................................
5 bar
outlet water temperature, less than .......................................80 "C
Electrode terminal and ceramic seal cooling
type ........................................................................................air
300 "C
temperature on the tube, max ..........................................
.
.
.
.
Maximum ratings
Frequency ......................................1000 MHz
Anode voltage .........................................6 kV
Anode current ...........................................3 A
.
...............1 O kW
Anode dissipation ...........
Control-grid dissipation ..........................
25 W
Screen-grid dissipation ........................ 75 W
(1) Thomson Tubes Electroniques defines the operating voltage according to each parficular situation
As an indication for equiprnent design purposes only a heater voltage of 6 Vproduces a heabng currenf of 65 A
(2) Values for cooling given for niaxirnum anode dissipation
Common Sound
amplification only
Typical Operation
at 800 MHz
in the matched cavity
TH 18565
TH 18565
I
I
2.2
-1 dB bandwidth
Intermodulation products
Gain
Anode voltage
Screen-grid voltage
Anode current, with signal
Screen-grid current
Control-grid current
Anode current at zero signal
11.5
- 52
16
5.5
600
1.6
10
negl.
0.9
4.4
11.5
11.5
kW
kW
MHz
16
5
500
16
5
700
2
15
1
0.9
dB
dB
kV
V
A
mA
mA
A
2.5
2
30
5
0.85
matched circuit assembly
For UHF-TV transmitters and translators
(Bands IV and V)
1,
I
Peak-of-sync output power
Sound carrier output power
Vision
only
".
L.
Operating frequency ....................................................
470 to 860 MHz
Dimensions ........................................................ 826 x 250 x 260 mm
Weight, approx (without tube) ..................................................... 34 kg
RF connections:
input ......................................
:................................
f e m a e type N
output ......................................................standard
EIA 1 5/8"
Cooling ................................................ ypervapotron and forced air
52
.*-
..
,,\ THOMSON TUBES ELECTRONIQUES
AM tetrode
TH 598
Output power
3kW
up to 120 MHz
General characteristics
Cathode ...................................................................
thoriated tungsten
Heating (1) ....................................................direct,
dc or single phase
Interelectrodes capacitances, approx.:
cathode-control grid ............................................................... 40 PF
control grid-screen grid ..........................................................75 pF
control grid-anode .................................................................0.4 pF
screen grid-anode ...............................................................11.5 pF Maximum ratings
Anode dc voltage ................................... 5 kV
Amplification factor, average ............................................................ 7
Control-grid voltage .......................... - 200 V
Transconductance (la = 1.5 A, Vg2 = 600 V) .........................40 mA/V
Screen-grid voltage ............................. 800 V
Operating position .....................................................................vertical
Peak cathode current ..............................
10 A
Weight, approx ...............................................................................
3 kg Anode dissipation ................................
5 kW
Dimensions ....................................................................see
page 55 Control-grid dissipation ..........................40 W
Anode cooling (2) .........................................................Hypewapotron Screen-grid dissipation ........................100 W
water flow, min ...................................................................... 2 Ilmn
water inlet pressure, max ........................................................ 5 bar
outlet water temperature ......................................................0 0 "C
Electrode terminal and ceramic cooling:
air
type ........................................................................................
250 OC
temperature on the tube, max ...........................................
T ~ ~ i coperation
al
carrier conditions
voltage according to each particular s~tuatron As an
indication for equipment design purposes only a heater
voltage of 6 V produces a heating current of 50 A
( 2 ) Values for cooling g i v e n for m a x i m u m a n o d e
dissipation
o u t b u t power
3
kW
Frequency
30
MHz
Anode voltage
4.5
kV
Screen-grid voltage
750
V
Control-grid bias voltage
- 120
V
1
A
Screen-grid current
1O
mA
Control-grid current
negligible
Anode current
THOMSON TUBES ELECTRONIQUES
( 1 ) Thomson Tubes Electroniques defines the operating
53
Power-grid tubes
Tube dimensions
54
,,\ THOMSON TUBES ELECTRONIQUES
THOMSON TUBES ELECTRONIQUES
1. INFORMATIONS TECHNIQUES
PREWIfaRE PARTI Z
1. INFORMATIONS TECHNIQUES
Le fonctionnement des tubes à grille est basé sur un
déplacement d'électrons d'une source, la cathode, vers
un collecteur, I'anode. La quantité d'électrons est
modulée dans le temps par une ou plusieurs grilles.
Si l'on applique dans une diode, c'est-à-dire dans un
tube qui n'est constitué que d'une cathode et d'une
anode, une tension positive croissante entre ces deux
electrodes, on obtient une courbe caractéristique :
Généralement, le courant n'atteint pas un palier car
l'effet du champ électrique (effet SCHOTTKY) n'est pas
négligeable.
Les tubes fonctionnent dans la zone de charge
d'espace. L'allure de la courbe caractéristique est
déterminée par les paramètres géométriques du tube.
Le rapport :
est appelée p e r v é a n c e et ne dépend que des
dimensions mécaniques des éléments du tube.
Les triodes sont des tubes à vide constitués d'une
cathode, d'une grille et d'une anode. La grille, placée
entre cathode et anode, contrôle le flux d'électrons qui
se déplace entre ces deux électrodes. Elle agit par son
champ électrique et doit capter le moins possible les
électrons émis par la cathode.
0,
73
O
C
-s
m
C
3
6
100083-111
O'
-
rlCJiil~
--
--
Tension d'anode (Va)
-
--
--
f'
----
1/16'
/,
ti(
--
-
La partie de la courbe caractéristique, dans laquelle
le courant électronique croît rapidement en fonction de
la tension est appelée zone de charge d'espace. En
effet, la présence d'électrons au voisinage de la cathode
mod~fiele champ électrique produit par I'anode. Le
courant varie comme la puissance 312 de la tension
selon la loi de LANGMUIR:
La tension continuant d'augmenter, la cathode atteint
sa saturation qui est fonction de la température et de la
nature du corps émissif. Le courant de saturation par
u n i t é de surface e s t d o n n é p a r l a f o r m u l e d e
RICHARDSON-DUSHMANN:
Lorsque, la tension d'anode étant positive, la tension
grille est suffisamment négative, le potentiel est négatif
au voisinage de la cathode et aucun électron ne peut
passer ; la et Ig sont nuls. Lorsque la grille devient moins
négative, les électrons émis par la cathode atteignent
I'anode et la commence à apparaître (voir figure 2 ) .
Enfin, lorsque la grille devient positive, le courant émis
par la cathode continue à croître, mais une partie de ce
courant est captée par la grille.
La figure 2 montre qu'avec de faibles variations de la
tension de grille, on peut provoquer des variations
i m p o r t a n t e s du c o u r a n t d ' a n o d e . C ' e s t l ' e f f e t
fondamental : il permet, en introduisant des circuits
convenables dans la grille et dans I'anode, de réaliser
des amplificateurs et des oscillateurs. Cette action
spécifique de la grille lui a fait donner le nom de grille de
commande.
Les courants la et
19
sont fonction des tensions Va et
Vg. Leur représentation se fait habituellement en
WS est le travail d'extraction des électrons du corps
émissif,
T est la température de la cathode,
k est la constante de BOLTZMANN,
A est la constante de RICHARDSON.
attribuant à l'un des trois paramètres la, Va, Vg, une suite
de valeurs fixes et en traçant le réseau des courbes qui
relient les deux autres paramètres entre eux. Trois
configurations sont ainsi possibles, dont la plus utilisée
est le réseau Vg = f(Va) à la constant, connu sous le nom
de caractéristiques à courant constant. A ce réseau, on
I
I
l
I. INFORMATIONS TECHNIQUES
observe effectivement, comme le montre la figure 3.
Si la tension d'anode est faible et la tension de grille
élevée, la forme du réseau est modifiée par la présence
d'un courant de grille important (partie gauche du réseau
de la figure 3).
-1
-
Trois paramètres principaux caractérisent le
fonctionnement de la triode:
Le coefficient d'amplification p, nombre sans
dimension, est égal à I'inverse de la pente des
courbes à la constant sur le réseau Vg-Va.
constante
,$te
2coJB
"9
Tension de grille (Vg)
ajoute généralement le réseau à
1g constant
(figure 3).
La notion de diode équivalente, d'après laquelle la ne
dépend que de Vg + Vaiy (y étant le coefficient
d'amplification du tube, égal à AVaJAVg pour la donné),
laisse prévoir que le réseau à la constant se compose
de droites parallèles de pente - 1 1 ~ .C'est ce qu'on
*
La pente s est le rapport de la variation du courant
d'anode à la variation de la tension de grille de
commande (réseau à Va constante). Elle se mesure
en mAN.
La résistance interne Ri représente I'inverse de la
pente des,courbes à Vg constante sur le réseau
la-Va ; elle se mesure en ohm.
Le p a r a m è t r e p d é p e n d , p e u d u p o i n t de
fonctionnement, sauf lorsque le courant de grille est
important; il caractérise donc la triode. Par contre, s et
Ri ne peuvent être spécifiés que pour un point de
fonctionnement donné.
En régime dynamique, le couplage capacitif
grille-anode limite les performances des triodes. Pour
pallier cet inconvénient, une seconde grille a été
intercalée entre la grille de commande et l'anode. Son
rôle d'écran électrostatique, qui réduit la capacité grille
de commandelanode, lui a donné son nom: la
grille-écran.
Figure 3 - ;:c?rira,-:Cr~::t~c;i
'es ,i coliranr constant d'iinf:tr;ode
I
1. INFORMATIONS TECHNIQUES
Les paramètres fondamentaux qui caractérisent le
fonctionnement de la tétrode sont :
Dans la tétrode, la grille de commande a le même rôle
que dans une triode; cependant la grille-écran, portée à
un potentiel positif, engendre par l'influence de son
champ un courant électronique dont la majeure partie
atteint l'anode. Les variations de la tension d'anode ne
sont pas totalement sans influence sur le courant
d'anode, mais le phénomène est très atténué. On a ainsi
séparé les fonctions générateur d'électrons et collecteur
d'électrons. La maîtrise du potentiel de la grille-écran est
très importante. En effet, toute surface bombardée par
des é l e c t r o n s émet, s e l o n s a n a t u r e et l e s
caractéristiques du faisceau incident, des électrons
secondaires. Si le matériau qui constitue la grille n'a pas
un coefficient d'émission secondaire très faible, le
courant de grille-écran sera mal contrôlé et pourra
entraîner des difficultés de fonctionnement ou de mise
en oeuvre du tube.
Le réseau le plus couramment utilisé est le réseau à
courant constant, tracé pour une tension de grille-écran
donnée:
Vgl = f(Va) la et Vg2 constants
*
le coefficient d'amplification pg1g2, nombre sans
dimension, égal au rapport des variations de
tension de la grille-écran et de la grille de
commande à courant d'anode constant:
Avg2
pg1g2 =
la et Va constants
AVgl
la pente s, en mAN, rapport de la variation du
courant d'anode sur la variation de tension de grille
de commande en un point donné du réseau :
Aia
s=*
Va et Vg2 constantes
AVg1
* la résistance interne Ri, rapport de la variation de la
tension d'anode à la variation du courant d'anode à
tensions de grille de commande et de grille-écran
constantes, exprimée en ohm :
AVa
Ri =
-Vg1 et Vg2 constantes
Ala
pglg2 est la principale caractéristique d'une tétrode. La
pente est donnée à titre indicatif, car sa valeur dépend
du point de mesure choisi.
-1
II UTILISATION DES TUBES DANS LES EMETTEURS DE RADlODlFFUSlON
II. UTILISATION DES TUBES DANS LES EMETTEURS DE
RADIODIFFUSION
1
l
\
L'évolution rapide des technologies (tubes, circuits
électroniques) autorise les constructeurs
d'équipements à proposer des émetteurs de forte
puissance de plus en plus performants et plus faciles à
exploiter.
Parallèlement, THOMSON a développé dans son
Département Tubes à Grilles de Puissance, puis intégré
dans ses fabrications, deux technologies originales (le
graphite pyrolytique et le refroidissement par système
Hypervapotron@)qui ont permis d'optimiser l'utilisation
des tétrodes.
Fonctionnement à des fréquences élevées (bande
O.C.).
" Energie consommée réduite grâce à l'utilisation de
nouveaux systèmes de modulation et à l'utilisation
plus fréquente du système de transmission B.L.U.
'
Réduction du nombre de tubes
1
Ce matériau a modifié totalement la structure interne
des tubes en conduisant à la réalisation de grilles
PyroblocQ.Ses principaux avantages sont:
* très bonne définition géométrique, conduisant à un
parfait alignement grille de cornmandelgrille-écran
(réduction des courants de grille-écran),
b,
1
Pour choisir un tube, le concepteur d'un émetteur
radio doit considérer les facteurs suivants:
* La puissance que doit fournir le tube à l'antenne; les
1
(
La linéarité dont dépend le taux de distorsion ou
d'intermodulation.
*
La tenue aux hautes tensions nécessitées par les
puissances et rendements élevés.
" Le gain qui permet de limiter le nombre de tubes
dans un émetteur.
* Les capacités interélectrodes qui influent sur les
facteurs cités ci-dessus (gain, linéarité, rendement).
La tenue aux surcharges de puissance etlou
tension provoquées par tout incident de
fonctionnement.
La recherche constante de l'amélioration de ces
facteurs a conduit à l'adoption des tétrodes au détriment
des triodes dans les émetteurs de puissance.
coefficient de dilatation négligeable, permettant
d'obtenir des distances interélectrodes faibles et
reproductibles (meilleur gain et meilleure tenue aux
hautes tensions).
"rande tenue mécanique à haute température
(bonne résistance aux surcharges).
*
émetteurs modernes n'utilisent généralement qu'un
seul tube en étage final.
Le rendement qui peut être atteint, compte tenu du
mode de fonctionnement retenu pour le tube (classe
de fonctionnement. amplification HF ou BF.
émetteurs DBL ou BLU ...).
1
1
Les caractéristiques les plus demandées sont :
@
1
@
conductibilité thermique élevée et pouvoir émissif
proche de celui du corps noir, donc excellentes
possibilités de dissipation (faibles tensions de
déchet, d'où rendement amélioré).
faible coefficient d'émission secondaire (linéarité
accrue).
Lr
systc rne H y p o 9,trp,tron
'
L'adoption du refroidissement d'anode par
vaporisation-condensation de vapeur in-situ a permis :
V e réduire l'encombrement de l'ensemble
tubelrefroidisseur, ce qui diminue les capacités
parasites anodefmasse.
de repousser les limites de dissipation maximale
d'anode loin des conditions de fonctionnement
nominales.
Ces deux technologies réunies ont autorisé, à
puissance donnée, la réalisation de tubes de plus faibles
dimensions. Les tubes peuvent donc fonctionner à des
fréquences plus élevées. La pente des tubes qui devrait
diminuer en raison des surfaces réduites de la cathode
et des grilles, est conservée grâce aux distances
interélectrodes plus faibles.
a
II. UTILISATION DES TUBES DANS LES EMETTEURS DE RADlODlFFUSlON
Conditions recherchées
Fonctionnement dans la bande O.C.
Gain
Triodes
Tétrodes
Difficile
( capacité grille-anode élevée)
Facile
Limité par la capacité grille- anode
Elevé
Limité par la puissance
dissipable sur la grille
Elevé
Faible tension de déchet
Médiocre
Bonne
Limité par la puissance
dissipable sur la grille
Facile
l
1
1
I
Rendement anodique
Linéarité
Fonctionnement en étage
HF modulé
111. TECHNOLOGIE
1 -
III. TECHNOLOGIE
-
Le choix du tungstène thorié est lié à son excellente
tenue en haute tension. La cathode en tungstène thorié
constitue une version améliorée de la cathode en
tungstène pur qui présente l'inconvénient de fonctionner
à température très élevée, conduisant à une grande
vitesse d'évaporation. En déposant une couche
monoatomique de thorium à la surface du tungstène, on
peut obtenir une densité d'émission satisfaisante avec
une température considérablement abaissée (de 1900
à 2000 "K).
La cathode prend la forme d'une "cage" cylindrique
(voir figure 5) dont les brins sont chauffés directement
par passage du courant. Cette structure cylindrique est
constituée par une sorte de grillage obtenu en soudant
en leurs points d'intersection deux ensembles de fils
disposés obliquement sur un cylindre. Ce cylindre est
soudé à ses extrémités sur des plateaux qui servent
d'amenées du courant de chauffage.
de tungstène qui permettra, au cours du fonctionnement
du tube, la réduction de la thorine et la diffusion du
thorium vers la surface, la couvrant d'une couche
monoatomique. On obtient ainsi des cathodes dont le
taux d'évaporation de thorium est plus bas que celui des
cathodes non carburées, ce qui permet de les faire
fonctionner à température plus élevée et avec des
densités de courant plus fortes. Elles résistent
é g a l e m e n t mieux aux g a z r é s i d u e l s et a u
bombardement ionique. Cette résistance est beaucoup
plus grande que celle des cathodes à oxydes, ce qui fait
préférer les cathodes en tungstène thorié pour les tubes
de puissance fonctionnant à des tensions élevées, en
dépit de la puissance de chauffage plus importante
qu'elles exigent.
La forme de la grille, sa distance à la cathode, et dans
une moindre mesure à l'anode, déterminent le réseau
de caractéristiques d'une triode. La nécessité de réduire
au maximum le courant capté par la grille conduit par
ailleurs à réaliser des grilles très transparentes,
c'est-à-dire dont les parties pleines sont petites par
rapport à la surface totale. Enfin, la recherche d'une
commande efficace et d'un fonctionnement à fréquence
élevée conduit à des distances faibles entre grille et
cathode.
Dans la tétrode, la réduction du courant de grille-écran
impose d'aligner parfaitement cette grille et la grille de
commande de façon que les électrons passant à travers
la première grille aient également une bonne probabilité
de passer à travers l a seconde. D'autre part, la
nécessité d'avoir une tension d'écran nettement moins
élevée que la tension d'anode conduit à une distance
faible entre grille de commande et grille-écran.
Le fil utilisé, de quelques dixièmes de millimètre de
diamètre, est un fil de tungstène contenant un faible
pourcentage de thorine. Pendant l'opération de
carburation, la cathode est portée à haute température,
dans une atmosphère d'hydrocarbure à basse pression.
Ce procédé crée en surface du fil une gaine de carbure
Pour les raisons analysées plus haut, l'utilisation de
matériaux conventionnels ne constitue pas une solution
satisfaisante pour la fabrication des grilles des tubes
modernes de plus en plus puissants et compacts. C'est
pourquoi THOMSON TUBES ELECTRONIQUES a
orienté ses recherches, il y a plus de 20 ans, dans une
voie originale et a développé un nouveau matériau, le
graphite pyrolytique, et un nouveau type de grille, la
grille Pyroblocm.
Le graphite pyrolytique, aussi appelé graphite orienté,
est essentiellement un graphite cristallisé obtenu par
décomposition thermique d'un hydrocarbure gazeux sur
111. TECHNOLOGIE
la surface d'un matériau porté à une très haute
température sous ambiance contrôlée. Une couche de
graphite pyrolytique est ainsi déposée, dont l'épaisseur
dépend de la durée et des paramètres de dépôt.
De même, les conditions dans lesquelles s'effectue le
dépôt influent sur la structure et les propriétés
mécaniques du graphite.
Les qualités essentielles du graphite pyrolytique
peuvent être groupées en quatre catégories ; elles
prouvent qu'il est le meilleur matériau qui puisse être
utilisé pour la fabrication des grilles des tubes de grande
puissance:
5
9
-5
De plus, l'excellente résistance aux chocs thermiques
et la grande stabilité du graphite pyrolytique aux hautes
températures autorisent les grilles Pyrobloc@à subir
sans dommage des anomalies de fonctionnement de
faible durée, contrairement aux grilles conventionnelles
qui seraient définitivement détruites dans des conditions
de surcharge similaires.
L'une des plus importantes qualités du graphite
pyrolytique réside dans sa très grande capacité de
rayonnement thermique, très proche de celle du corps
noir théorique.
Propriétés émissives
II est bien connu que le graphite présente des effets
d'émission secondaire bien plus faibles que d'autres
matériaux tels que le molybdène, le tantale ou le
tungstène. De plus, l'émission thermique est forcément
réduite, grâce à l'abaissement de la température de
fonctionnement de la grille, rendu possible par la bonne
conductibilité thermique du graphite.
5.10"
O
C
al
s
al
.-g
10.'
E
--2
5.10'~
.al
.-
O
Y
U
3
2
O
10'~
O
5.10."
1
Grâce à ces propriétés, la chaleur dissipée sur la grille
peut être facilement transférée vers les structures de
support. Ce transfert est d'autant plus aisé que la grille
Pyrobloc@est réalisée d'une seule pièce, contrairement
aux autres grilles comportant des points de soudure.
La figure 7 montre que le coefficient de dilatation
thermique linéaire du graphite pyrolytique dans la
direction parallèle au plan de dépôt (ab) est faible. II
s'ensuit une variation négligeable du diamètre de la
grille Pyrobloc@,ce qui permet de réaliser un espace
interélectrode extrêmement faible, condition exigée
pour les tubes fonctionnant à très haute fréquence.
1
2
-2
Propriétés thermiques
La figure 6 montre la conductibilité thermique de
divers matériaux en fonction de la température. On peut
remarquer que la conductibilité thermique du graphite
pyrolytique dans une direction parallèle au plan de dépôt
(ab) est très élevée, du même ordre que celle du
tungstène et du cuivre. Par contre, dans la direction (c)
perpendiculaire au plan de dépôt (ab), la conduct~bilité
thermique est très faible, inférieure à celle de la zircone
stabilisée.
100083-511
1O
-273 O
500
1O00 1500 2000 2500 3000
Température en "C
Figure 6 - Condi~ctibiiitetherri~~que
des divers
n7aterialix d~ grille
100083-611
25
2
L
m
a
L?
4
--,
al
20
O
.-2
(O
'C
.-
15
al
1
0
Eal
+
-.-
10
C
.-O
a
m
73
al
-0
5
C
.-w
-w
,-O
O
O
-273 O
500
1000
1500
2000
2500
3000
Température en "C
F i g u r ~7 - Coefficient de d ~ l a itiorl
t
'7er17iiqiie
des d~versmaferiniix (regi !e
1
I
I
1
I
1
I
1
I
1
I
lll. TECHNOLOGIE
Propriétés mécaniques
Fabrication des grilles pyrobloc@
Les propriétés mécaniques du graphite pyrolytique
sont nettement supérieures à celles des matériaux
utilisés jusqu'à ce jour, comme en témoignent les
chiffres suivants :
Pour aboutir à la fabrication industrielle des grilles
Pyrobloc@,un grand nombre d'obstacles a dû être
surmonté. L'une des difficultés pratiques rencontrée
était l'impossibilité de trouver sur le marché des qualités
de g r a p h i t e a s s e z pur pour s a t i s f a i r e aux
caractéristiques exigées. Ce problème a été résolu en
utilisant le procédé de dépôt de graphite pyrolytique à
haute température décrit plus haut, pour réaliser une
ébauche de grille. A partir de cette ébauche, on réalise
une grille à mailles croisées ou parallèles (voir figure 9);
grâce à un procédé original, on peut fabriquer toutes
sortes de grilles à mailles fines avec des brins de section
aussi faible que 0,01 mm2.
Résistance à la flexion, dans le plan (ab) :
1700 kg/cm2
Résistance à la traction, dans le plan (ab) :
1100 kg/cm2
a
Résistance à la compression, dans le plan (ab) :
1500 kg/cm2
*
Résistance à la compression, direction (c) :
5000 kg/cm2
Contrairement à d'autres matériaux, la résistance
mécanique du graphite pyrolytique augmente avec la
température. Grâce à l'excellente stabilité à haute
température (la pression de vapeur à 1850 OC est de
10.' torr), la grille peut fonctionner à une temperature
égale à celle d'une cathode en tungstène thorié.
'
Propriétés électriques
L'anisotropie électrique est liée à la structure
cristallographique du matériau, ce qui se traduit par une
différence de résistivité électrique entre la direction
parallèle au plan (ab) et la direction (c). (figure 8).
De plus, la résistivité électrique dans le plan (ab) reste
pratiquement constante, égale à sa valeur minimale
dans des conditions de températures normales des
tubes à grille. A haute température, le graphite
pyrolytique est aussi bon conducteur que le tungstène
ou le molybdène, ce qui limite l'échauffement par effet
Joule.
- - --- - -
---y"
- --------:O0083 7
1
5.10.'
1
Figure 9 - G/!:ieP L;obioc d une tetrode
1 O-'
5.1
On obtient ainsi des grilles sous forme monobloc.
Autrement dit, tous les éléments (le dôme, le maillage,
l'embase) forment une structure continue sans points de
soudure ni assemblage mécanique. Cette technique
originale et tous ces procédés de fabrication, qui ont fait
l'objet
de
brevets
THOMSON
TUBES
ELECTRONIQUES, ont permis de franchir une étape
décisive dans la réalisation de grilles Pyroblo6'
destinées aux tubes de grande puissance.
1
5.1
1
5.IO'"
1 0-4
5.1
1O-"
5.1
1
5.10.'
1 O-'
5.10.'
1
-273O
L'anode des tubes de puissance est une électrode en
cuivre qui enveloppe l'ensemble des autres électrodes.
500 1000 1500 2000 2500 3000
Température en O
C
Figure 8 - R e s i s t i ~ ~i,iecliiqcic
~té
dcs divers
I
rni7iei57~ix JE gt:!/e
1O
Son rôle est multiple: elle collecte les électrons,
transmet l'énergie dissipée, assure l'échange thermique
et participe à l'étanchéité au vide du tube. Sa forme et
ses dimensions sont essentiellement déterminées par
la puissance qu'elle doit dissiper.
111. TECHNOLOGIE
Pendant le fonctionnement du tube, I'anode est portée
à une tension élevée; l'isolement électrique avec les
dispositifs de refroidissement, généralement à la
masse, devra être respecté.
Pour les niveaux de puissance couramment utilisés
dans les émetteurs de radio-diffusion, le refroidissement
de I'anode nécessite des modes de refroidissement très
efficaces, notamment la convection forcée de I'air et les
systèmes Supervapotron et HypervapotronQ.
Refroidissement par air forcé
Les anodes refroidies de cette manière sont munies
d'ailettes (figure I O ) , ce qui augmente la surface
d'échange entre le fluide de refroidissement et I'anode.
L'efficacité du refroidissement est encore accrue par
une augmentation de la vitesse de I'air (30 m/sec.par
exemple).
Un échange thermique efficace est obtenu par la
vaporisation directe de I'eau en contact avec une anode
comportant des protubérances massives. La vapeur
d'eau est canalisée puis condensée dans un circuit
extérieur.
Le refroidissement anodique d'un Supervapotron est
assuré pour autant que l'anode demeure en contact
avec I'eau, ce qui oblige à respecter un niveau d'eau
minimum.
L'emploi d'une installation Vapodyne assure le
maintien du niveau d'eau entre les limites admises, la
condensation de la vapeur en circuit fermé et
l'évacuation de la chaleur. Cette installation doit être
vérifiée, conformément à la notice particulière du tube
utilisé.
L'air est canalisé sur les ailettes, le débit d'air étant
obtenu par un ventilateur dont les caractéristiques
doivent respecter les consignes de débit et de pression
indiquées pour le type de tube concerné.
Ce dispositif présente l'avantage d'assurer de façon
simple l'isolement de I'anode. Les inconvénients sont
liés à l'utilisation d'un ventilateur parfois bruyant et qui
consomme une énergie non négligeable; de plus, la
nécessité d'augmenter la surface d'échange de I'anode
conduit à des tubes plus lourds.
Le refroidissement par HypervapotronQ (figure 11)
constitue le dernier perfectionnement apporté à l'effet
V a p o t r o n d é c o u v e r t par T H O M S O N T U B E S
ELECTRONIQUES il y a plus de 30 ans. L'effet
Hypervapotron@réside dans la combinaison de deux
phénomènes :
La dissipation maximale de ce type de refroidissement
est de l'ordre de 20 kW.
*
Figure 10 - Tube à refroidissement à ail
d'une part, l'ébullition stable et complexe à
l'intérieur de fentes étroites dans la structure
extérieure de I'anode.
Figure I I - Tube ,. refv dissement par lc systenlc
h1/per ipOilOl?
,
111. TECHNOLOGIE
d'autre part, la condensation immédiate de la
vapeur expulsée des fentes par un courant d'eau
perpendiculaire à celles-ci et circulant à l'intérieur
d'une chemise coaxiale.
La figure (12) illustre cette technique. La vapeur se
forme dans la fente (figure 12a), s'en échappe à grande
vitesse (figure 12b), puis est immédiatement condensée
par le courant d'eau. La fente est réalimentée en eau
par aspiration entre deux jets de vapeur (figure 12c).
*n
Circulation d'eau
Pellicule
\
2 kWlcm2 en régime continu. Les tubes électroniques
Hypervapotron travaillent aux environs de 300 W/cm2,
donc avec une très grande marge de sécurité.
Les isolateurs céramiques d'un tube de puissance a
grille (figure 13) doivent assurer de nombreuses
fonctions :
une isolation électrique entre les différents collets
(sortie d'électrodes),
une étanchéité parfaite,
une bonne tenue mécanique à des températures de
fonctionnement élevées.
Les céramiques, à haute teneur en alumine, satisfont
les critères précédents et permettent le développement
de tubes plus puissants ou travaillant à tension plus
élevée.
Leurs principales propriétés physiques sont :
1
Liquide
,/fl
Chemise
d'eau
Rigidité diélectrique : 20 kV/mm
Conductibilité électrique à 20 OC : < 1
Cl
-'m.'
Angle de perte à 1 MHz: tg a G 1 0 . ~
Figure 12 - Pr1r7c1ped c foi?ctionni ~ ~ i e idi]
- i ! systeme
-
HV;l( ~ r v ~ ~ ~ ~ o f ~ o / ~
La condensation instantanée de la vapeur réduit les
effets perturbateurs causés par le volume de vapeur
engendré et élimine l'emploi d'un condenseur externe.
La température de sortie de l'eau de refroidissement
n'est pas primordiale pour autant qu'elle demeure
au-dessous de 100 OC à la pression atmosphérique.
L'eau chaude à la sortie du système peut être utilisée
par l'intermédiaire d'un échangeur eau-eau pour le
chauffage de bâtiments ou pour d'autres applications.
Des essais de dissipation ont permis d'atteindre
Bonne conductibilité thermique (30 W m.' OC-')
entraînant une bonne résistance aux chocs
thermiques.
Bonne tenue mécanique à température élevée (le
point de ramollissement n'apparaît qu'à 1600 O C ) .
Les procédés d'usinage par rectification permettent de
respecter des tolérances sévères et d'obtenir une
précision déterminante pour la qualité des tubes à
structure coaxiale.
Les scellements céramique-métal obtenus par un
procédé sophistiqué permettent d'atteindre des
températures d'utilisation élevées sans conséquences
sur la durée de vie du tube.
,
IV. CONNECTEUR
IV. CONNECTEUR
Le débit et la pression de I'air doivent être conformes
à la notice afin que la température des collets,
scellements céramique-métal et céramiques ne
dépassent pas la température maximale définie dans la
notice particulière du tube.
Les tubes électroniques sont prévus pour être montés
en position verticale sur un support approprié, le
connecteur (figure 14), dont le but est de permettre la
liaison avec les électrodes et le refroidissement par
ventilation forcée des collets (sorties d'électrodes) et
des céramiques.
L'ensemble tube/connecteur a été étudié afin
d'assurer le fonctionnement du tube aux fréquences
élevées.
La connexion des électrodes est assurée par des
contacts en cuprobérylium. Leur élasticité permet
une bonne pression de contact et le passage de
courants élevés.
L'air de refroidissement est canalisé par le
connecteur sur les collets. Ceux-ci sont percés pour
que I'air refroidisse efficacement les scellements
céramique-métal.
+
Plan de
référence
------
Anode
1/
Trous de
Grille de
commande
Filamentcathode
Filament
Eclateur
Grille
écran
Figure 14 - Coiij)e d'un connilcteor dc, tetrode
.
Un positionnement correct du tube dans le
connecteur est impératif. Compte tenu de son
poids, le tube doit être supporté par le collet
d'anode; le plan de ce collet est pris comme plan de
référence et la position du connecteur doit être
déterminée par rapport à ce plan.
Dans ces conditions, une ventilation correcte est
obtenue car les trous de passage d'air des collets
ne sont pas obstrués et la connexion des électrodes
est réalisée dans les zones de contact indiquées
dans la notice.
* Des précaut~onssont à prendre lors de la mise en
place et du retrait des tubes afin que les contacts ne
soient pas aplatis ou arrachés, ce qui augmente la
résistance du contact électrique, d'ou risques
d'échauffement et de destruction des sorties
d'électrodes du tube. Une ventilation incorrecte des
électrodes provoque l'échauffement des contacts et
la perte de leur élasticité. II est nécessaire de
vérifier périodiquement l'état des contacts.
' Le connecteur comporte des découplages
cathodelmasse et grille-écranlmasse, réalisés en
Kapton* métallise sur les deux faces, ce qui permet
d'obtenir de fortes valeurs de capacité avec des
tensions d'isolement élevées. Ces capacités
peuvent cependant ne pas être suffisantes en
basse fréquence. II est alors nécessaire de les
compléter par des condensateurs appropriés.
Des éclateurs grille de commande/masse et
grille-écranlmasse, réglés en usine, participent à la
protection du tube en limitant les surtensions
accidentelles sur les électrodes.
' KAPTON Brevet DUPONT de NEMOURS (USA)
V. RECOMMANDATIONS SUR L'UTILISATION DU TUBE LORS DE LA CONCEPTION DE L'EQUIPEMENT
V. RECOMMANDATIONS SUR L'UTILISATION DU TUBE
LORS DE LA CONCEPTION DE L'EQUIPEMENT
Les triodes et tétrodes pour radiodiffusion de
THOMSON TUBES ELECTRONIQUES sont conçues
et fabriquées pour offrir à I'utilisateur de hautes
performances et une longue durée de vie.
Quand ces tubes sont installés dans les circuits
fabriqués ou approuves par THOMSON TUBES
ELECTRONIQUES I'utilisateur peut avolr l'assurance
qu'ils fonctionnent dans le meilleur environnement
Cependant, quelle que soit la conception de ces
circuits, I'utilisateur doit prendre un certain nombre de
précautions et suivre les procédures de réglage
r e c o m m a n d é e s s ' i l veut tirer l e s m e i l l e u r e s
performances du tube. II devra consacrer le temps
nécessaire pour lire soigneusement et appliquer les
recommandations données dans ces paragraphes.
Au cas où I'utilisateur aurait besoin d'informations
complémentaires, ou s'il désire une assistance pour une
installation particulière, il peut contacter THOMSON
TUBES ELECTRONIQUES soit directement, soit par
l'intermédiaire d'un de ses représentants.
La stabilité mécanique de la cathode a toujours été un
facteur important de fiabilité et de durée de vie du tube
électronique. Ce facteur devient primordial dans les
tubes modernes de radiodiffusion, compte tenu de la
faible distance entre l a cathode et la grille de
commande. Trois paramètres principaux sont à
considérer :
Les tubes d'émission sont munis de cathodes en
tungstène thorié, à chauffage direct.
La durée de vie du tube est liée en premier lieu à la
température de la cathode. Celle-ci est définie non
seulement par la puissance de chauffage, donc la
tension de chauffage appliquée à la cathode, mais
également par la puissance dissipée sur les grilles, le
courant de cathode et les pertes RF. C'est la raison pour
laquelle la valeur nominale de la tension de chauffage
n'est pas une caractéristique générale, mais doit être
définie selon les conditions d'utilisation du tube. Ces
conditions doivent être transmises à THOMSON
TUBES ELECTRONIQUES qui déterminera la valeur de
la tension de chauffage de fonctionnement et en
informera I'utilisateur.
Cependant, pour prédéterminer les caractéristiques
du transformateur de chauffage, nous indiquons dans
nos notices la valeur approximative des tensions et
c o u r a n t s de c h a u f f a g e q u a n d a u c u n a u t r e
réchauffement de cathode n'intervient.
En plus d'une définition correcte de la tension de
chauffage, l'obtention d'une longue durée de vie de la
cathode nécessite de réguler cette tension. La tolérance
permise est normalement $r 2 %. II est important de noter
que des tensions de chauffage soit supérieures, soit
inférieures à la tension de fonctionnement sont
également mauvaises pour le tube. Une surchauffe
provoque une évaporation rapide du matériau émissif
de la cathode tandis qu'un sous-chauffage entraîne un
empoisonnement de la cathode. Dans les deux cas, la
durée de vie du tube s'en trouve écourtée.
Lors de l'application de la tension de chauffage, il est
nécessaire non seulement de limiter l'appel de courant,
compte tenu de la très faible résistance de la cathode à
froid, mais également de considérer les facteurs
thermiques de la cathode.
Lors de l'allumage d'une cathode en cage, les fils de
tungstène, à faible inertie thermique, se dilatent dès
l'apparition de la tension de chauffage, alors que le
support de la cathode, constitué de pièces massives,
chauffe plus lentement.
Ces différences de dilatation peuvent entraîner des
déformations permanentes du fil de cathode donc des
dérives des caractéristiques du tube, et même des arcs
ou des courts-circuits intermittents entre la cathode et la
grille de commande provoquant des disjonctions du
tube. II est donc nécessaire de prendre des précautions
pour appliquer la tension de chauffage afin de pallier ces
inconvénients.
La limitation du courant d'appel à l'application de la
tension de chauffage est obtenue grâce à un processus
basé sur un sous-chauffage permanent de la cathode à
partir duquel la tension de chauffage peut être appliquée
progressivement (Figure 15b) ou directement (Figure 15a).
Si la tension de chauffage de fonctionnement est
appliquée directement (Figure 15a), le courant crête à
l'enclenchement ne doit pas dépasser la valeur
maximale indiquée dans la notice du tube.
Ce processus est impératif pour tous les tubes, à
I'enclenchement comme à la coupure de la tension de
V. RECOMMANDATIONS SUR L'UTILISAT/ON DU TUBE LORS DE LA CONCEPTION DE L'EQUIPEMENT
Figure 15 - Ai plicnt~oi de /,i teiîsion de rhai~ffaged7ns le (-asd lin s-mir-cilauffngepcir?>lineni
chauffage de fonctionnement Le mode d'application et
de coupure est défini pour chaque tube dans la notice
correspondante.
En régime de sous-chauffage, on maintient en
permanence une tension réduite. pour porter la cathode
à unetempérature environ moitié de la température de travail.
Dans ces conditions
* La puissance consommée est environ égale au
Ill Oème de la puissance nominale de chauffage et il
n'est pas nécessaire de maintenir le refroidissement
du tube (air forcé sur les connexions, circulation
d'eau sur I'anode). Toutefois, des précautions
doivent être prises pour assurer une libre circulation
de l'eau de réfroidissement (effet thermosiphon).
La température de cathode étant réduite, elle
n'influence pas la durée de vie du tube.
Comme auparavant, c'est lorsque la tension de
chauffage de fonctionnement est appliquée que la durée
de vie garantie est prise en compte ; il n'est plus
nécessaire d'utiliser un transformateur de chauffage à
fuite magnétique, le courant d'appel à l'application de la
tension étant limité par la résistance de la cathode
sous-chauffée.
A noter qu'en cas de nécessité la pleine tension de
chauffage peut être appliquée à partir de O à la condition
que l'amplitude du courant a l'enclenchement ne
dépasse pas celle définie dans la notice.
I
I
1
Le contacteur de chauffage doit être asservi aux
sécurités de refroidissement du tube (sorties électrodes
et a n o d e ) . A l a c o u p u r e d u c h a u f f a g e , une
p o s t v e n t i l a t i o n d e s s o r t i e s é l e c t r o d e s et le
refroidissement d'anode doivent être maintenus
pendant au moins 3 minutes. Dans le cas d'un arrêt
général et volontaire de l'émetteur, il est recommandé
de passer par le sous-chauffage durant la période de
postventilation définie précédemment (3 mn).
Dans tous les cas, il est recommandé d'éviter les
coupures de tension de chauffage qui provoquent des
contraintes de la structure de cathode. Pour des
interruptions relativement courtes de la haute tension
telles les interruptions d'émetteurs OC, il est également
recommandé de maintenir la tension de chauffage de
fonctionnement.
Y-
b,
L*
,
""1"'
& ; - v~ & ~ 2 & + & ~ ~ . z d ~ &g * a
&
Les hautes performances des tubes THOMSON
T U B E S E L E C T R O N I Q U E S sont o b t e n u e s
principalement grâce à la technologie du graphite de
pyrolyse,
Sur le plan électrique, les avantages essentiels sont
un moindre traînage des caractéristiques, un risque
d'apparition et d'évolution d'émission thermique et
secondaire plus faibles et une capacité de dissipation
élevée.
II en résulte que la nécessité d'une faible impédance
des sources d'alimentation est moins importante et la
régulation plus aisée que pour les grilles de technologie
classique.
Dans tous les cas, un dispositif de protection contre
les surintensités doit être prévu [sécurité de surintensité
à coupure rapide (100 msec. max.), réglée à 1,5 fois le
courant normal de fonctionnement].
De plus, il est impératif de prévoir un éclateur entre les
grilles et la masse pour limiter les surtensions
éventuelles pouvant apparaître sur ces électrodes. Ces
éclateurs sont montés sur les connecteurs THOMSON
TUBES ELECTRONIQUES décrits dans les notices
particulières.
Le refroidissement de l'anode par Hypervapotron offre
un large coeffic~entde sécurité pour la dissipation
d'anode, et les surdissipations brèves qui peuvent
apparaître dans un équipement lors de réglages ou
d'incidents sont facilement acceptées.
En plus des consignes générales de sécurité liées à
l'emploi de hautes tensions, la source d'alimentation
anodique doit être asservie impérativement aux
dispositifs de sécurité du tube :
* Sécurités de refroidissement anode,
Tension de chauffage et tension de polarisation,
* Dispositifs de surintensités d'anode, de grille de
commande et de grille-écran,
V. RECOMMANDATIONS SUR L'UTILISATION DU TUBE LORS DE LA CONCE ->TIONDE L'EQUIPEMENT
* Autres dispositifs de sécurité liés au circuit
d'utilisation et aux impératifs de sécurité du
personnel.
Le tube doit également être protégé par un détecteur
d'arc contre l'éventualité d'arcs internes et de
surdissipation liés à des désadaptations éventuelles.
L'installation d'un crow-bar est recommandée dans le
but de dériver le courant de décharge du condensateur
de filtrage de l'alimentation HT en cas de flash dans le
tube. L'efficacité de ce dispositif sera vérifiée par un
essai de mise en court-circuit du redresseur
Pour celà, le redresseur est porté à ia tension
nominale de fonctionnement et le relais de surintensité
réglé à la sensibilité normale. Un court-circuit franc est
alors provoqué entre les conducteurs d'aiimentation
d'anode et de cathode par l'intermédiaire d'un fil de
cuivre de diamètre 301100 mm et de longueur 2 cm/kV
environ. Le système doit éviter la fusion du fil de cuivre.
En cas de fonctionnement, le crow-bar doit couper
simultanément la tension d'excitation, la tension de grille
écran et la tension d'anode.
L'anode peut être refroidie soit par vaporisation
(Supervapotron ou HypervapotronB) avec circulation
d'eau de refroidissement, soit par air forcé. Le
refroidissement de I'anode par HypervapotronB est
choisi quand on dépasse un niveau de puissance
déterminé.
La notice individuelle de chaque tube fournit des
informations importantes concernant la pression et le
débit de I'eau de refroidissement, auxquelles l'utilisateur
doit se conformer rigoureusement. D'autre part, on doit
utiliser de I'eau déminéralisée dont la résistivité doit
dépasser 500 kS2.cm.
Les tubes Hypervapotron@sont fournis montés dans
un refroidisseur. L'entrée d'eau est marquée en bleu
avec la référence "IN", la sortie d'eau en rouge avec la
référence "OUT". L'eau de refroidissement doit arriver
par I'entrée et I'eau de sortie chaude s'évacuer par la
sortie.
Pour obtenir les performances de dissipation du tube,
les sécurités à prévoir sont :
pression à l'entrée,
débit,
Les tensions doivent être appliquées en cascade dans
l'ordre suivant* : tension de chauffage, tension de
polarisation, tension d'anode, tension de grille-écran,
tension d'excitation.
A l'arrêt, il faut observer l'ordre inverse pour la coupure
des différentes tensions.
En cas de nécissité d'appliquer les tensions dans un ordre different, consulter
THOMSON TUBES ELECTRONIQUES
résistivité de I'eau,
* température d'entrée et de sortie de I'eau.
II est conseillé pour obtenir une exploitation stable :
de prévoir une régénération de I'eau par résine de
façon à maintenir la résistivité de I'eau à une valeur
correcte.
de filtrer I'eau de refroidissement pour éliminer toute
particule solide qui pourrait obstruer le passage de
I'eau de refroidissement et provoquer des
surcharges locales de I'anode.
II est nécessaire de prévoir le refroidissement:
Refrb ~frsse/;~er7r
par a1r force
de I'anode du tube,
* des isolants (céramiques),
Le refroidissement de I'anode par air forcé est réalisé
pour les tubes de dissipation anodique maximale de
20 kW.
des sorties d'électrodes.
Quel que soit l e mode de fonctionnement, le
refroidissement doit être mis en service avant la tension
de chauffage et maintenu pendant 3 minutes au moins
après la coupure de cette tension.
II est impératif que I'air de refroidissement soit
correctement filtré pour éviter tout encrassement qui
pourrait réduire le débit d'air et provoquer des
surdissipations locales sur I'anode.
Les sorties d'électrodes et les céramiques sont
refroidies par air forcé filtré dont le flux doit être
correctement canalisé pour refroidir efficacement les
scellements et les sorties d'électrodes. Les connecteurs
THOMSON TUBES ELECTRONIQUES répondent a
cette demande et leur emploi est conseillé (voir
paragraphe IV).
La température des scellements céramique-métal et
des céramiques ne doit pas dépasser la température
maximale indiquée dans la notice particulière du tube.
Une sécurité de débit d'air à l'entrée, reliée aux
dispositifs de protection du tube, doit être prévue.
Le filtre à air doit être nettoyé périodiquement de façon
à maintenir le débit à la valeur requise. Un contrôleur de
débit d'air doit être prévu et relié aux dispositifs de
protection du tube.
La température de I'air de refroidissement à la sortie
ne doit pas dépasser la valeur limite de 100 OC. Par
conséquent, une signalisation de dépassement de cette
température doit être installée par l'utilisateur de façon
à le prévenir en cas d'une température excessive, dont
la cause peut être soit un'mauvais réglage, soit un
mauvais fonctionnement. Ce dispositif doit déclencher
les relais de protection du tube.
V. RECOMMANDATIONS SUR L'UTILISATION DU TUBE LORS DE LA CONCEPTION DE L'EQUIPEMENT
I
I
(
(
Les caractéristiques de refroidissement par air forcé
de l'anode ainsi que des autres électrodes sont
indiquées dans la notice du tube, pour le type de
connecteur recommandé.
La correction de perte de charge s'effectue en
appliquant à la valeur de la perte de charge dans
les conditions standard le coefficient correctif ya. Si
la température de sortie dépasse 100 OC, on
appliquera le coefficient ya yb.
Elles sont définies dans les conditions standard :
altitude : O
température : 20 OC
Caractéristiques de refroidissement sur site
Choix du ventilateur
Pour une installation située à une altitude supérieure
à celle du niveau de la mer et à une température
s u p é r i e u r e à 2 0 OC, l e s c a r a c t é r i s t i q u e s de
refroidissement doivent être modifiées afin de tenir
compte de la variation de la masse volumique de I'air
avec l'altitude et la température.
Les constructeurs de ventilateurs donnent en général
les caractéristiques débitlpression dans les conditions
standard (altitude 0, température ambiante 20 OC).
La correction de débit s'effectue en appliquant à la
valeur du débit dans les conditions standard, le
coefficient
Le débit restera inchangé, car le ventilateur fonctionne
à vitesse constante. Par contre, la pression devra être
modifiée en appliquant à nouveau les coefficients ya et
éventuellement yb.
II est donc nécessaire, lors du choix d'un ventilateur,
de ramener aux conditions standard les caractéristiques
de refroidissement trouvées pour le site d'installation.
Dans les conditions standard, les caractéristiques du
ventilateur seront donc :
PO= pression atmosphérique au niveau de la mer.
P = pression atmosphérique du lieu de l'installation.
te = température d'entrée de I'air (en OC).
I
Ce coefficient ya modifie le débit d'air pour maintenir
constante la masse d'air échangée par unité de temps.
)
Dans le cas où la température de sortie d'air ( t s )
dépasse 100 OC, il est nécessaire d'appliquer un
deuxième coefficient correctif yb afin d'augmenter la
masse d'air échangée par unité de temps.
I
Qn = débit indiqué dans la notice du tube
Q = débit du ventilateur
y= ya ou ya x yb, suivant le cas
Pression : P = Pn x 'y2
Pn = perte en charge selon la notice
P = pression statique du ventilateur
y= ya ou ya x yb, suivant le cas
Tableau I - Valeurs de ya en fonction de la température d'entrée de I'air et I a1titi:de locale
Temperature
d'entrée de 1 air
Alt~tudclocale au-dessus du ,ive.&ude la rner (rn)
( C)
O
500
1000
1500
2000
2500
3000
3500
4000
O
0,92
0,98
1,04
1,01
1,17
1,25
1,33
1,43
1,52
1O
0,95
1,Ol
1,07
1,14
1,21
1,29
1,38
1,47
1,57
20
0,98
1,O4
1,11
1,18
1,24
1,33
1,42
1,52
1,62
25
1,OO
1,06
1,13
1,20
1,27
1,36
1,45
1,55
1,65
30
1,02
1,08
1,15
1,18
1,30
1,39
1,48
1,58
1,68
40
1,05
1,11
1,19
1,26
1,33
1,43
1,52
1,63
1,73
50
1,08
1,14
1,22
1,30
1,37*
1,47
1,57
1,67
1,78
VI. MAINTENANCE
VI. MAINTENANCE
Sécurité et automaticité
Une bonne maintenance de l'équipement est
nécessaire pour assurer une longue durée de vie du
tube.
Elle doit être régulièrement effectuée suivant les
indications détaillées de la notice de l'émetteur. En cas
d'anomalie de fonctionnement, toute défaillance des
systèmes de sécurité peut entraîner une détérioration
du tube par défaut de protection.
Nous rappelons les points importants concernant
directement le tube et qui devront être particulièrement
surveillés :
Vérifier :
-
*
les séquences d'application des tensions et leur
temporisation,
*
les dispositifs de protection contre les surintensités,
*
le système de coupure rapide ("crowbar"),
a
les sécurités concernant le refroidissement:
débit, température et pression de l'agent
réfrigérant (air ou eau),
niveau d'eau,
résistivité de I'eau.
Chauffage
Vérifier la tension de chauffage aux bornes du
connecteur à l'aide d'un voltmètre de classe 1,5
indiquant la valeur efficace vraie (ferromagnétique,
thermique ou numérique).
Si cette tension n'est pas correcte, avant de la
modifier, vérifier au préalable le régulateur de tension
secteur et les contacts filament et filamentIcathode du
connecteur.
Dans le cas où le sous-chauffage permanent est
installé, vérifier la tension de sous-chauffage permanent
et le fonctionnement de l'installation hydraulique en
thermosiphon.
* Systèmes ~ ~ ~ e r v a p o t r oetnSupervapotron
@
Vérifier la propreté et la qualité de I'eau, l'état
des raccords antiélectrolytiques.
Eiiminer les fuites d'eau éventuelles.
Système Supervapotron: contrôler le niveau
d'eau.
Refroidissement par air
Entretenir les ventilateurs.
Nettoyer les filtres à air.
II faut s'assurer du bon état de t'environnement
immédiat du tube :
* connexions et accessoires destinés au
raccordement des électrodes du tube,
* contacts du connecteur,
* découplages,
* aspect et réglage des éclateurs de protection
Lors du retrait d'un tube hors service, quelle que soit
sa durée de fonctionnement et avant d'installer le tube
de remplacement, il faut examiner les circuits et le tube
pour relever et corriger les anomalies éventuelles :
les traces d'échauffement,
les traces de flashes,
les traces de mauvais contact.
L'origine de ces anomalies peut être recherchée dans :
le système de refroidissement,
le positionnement du tube sur son support,
* un vieillissement des contacts,
* un mauvais état des condensateurs de découplage,
* des déréglages accidentels des circuits,
des circuits amortisseurs défectueux.
VI/. TRANSPORT - MANUTENTION - STOCKAGE
VII. TRANSPORT - MANUTENTION - STOCKAGE
Le tube est livré dans un emballage spécialement
conçu contre les chocs et les vibrations pouvant se
produire dans les conditions normales de transport.
Le stockage doit être réalisé dans un local sec et à
l'abri de la poussière. Tous les tubes doivent être
stockés en position verticale :
soit dans leur emballage,
Contrôle du tube dans l'emballage
Dès réception, afin de déceler les dommages que le
tube aurait pu subir au cours du transport, il faut, sans
sortir le tube de son emballage :
s'asurer du bon état de I'emballage extérieur et
intérieur,
dans le cas où la caisse est équipée d'un témoin de
renversement, vérifier son état,
vérifier la continuité du filament et l'absence de
court-circuit entre électrodes à I'aide d'un
ohmmètre. Pour les tubes Hypervapotron et
Supervapotron, cette opération peut s'effectuer
sans sortir le tube de son berceau.
Contrôle du tube hors de I'ernballage
Les tubes de grande puissance à refroidissement
Hypervapotron et Supervapotron sont livrés montés sur
une chaise support. Celle-ci est prévue pour assurer la
manutention et la protection du tube pendant son
stockage.
Sortir l'ensemble tube
de levage (figure 16).
+ chaise à I'aide du dispositif
S'assurer que le tube ne porte pas de traces de
chocs.
Déplacer I'ensemble tube + chaise à I'aide d'un
chariot équipé de roues pneumatiques, jusqu'à la
position de service en évitant tout choc et en ayant
pris soin d'éviter les obstacles.
Mettre le tube en place dans l'équipement en suivant
les instructions du paragraphe V11.3 "Première mise en
service".
Démarches à effectuer en cas de dommages
Se référer aux consignes indiquées au verso du
b o r d e r e a u de l i v r a i s o n joint dans l a pochette
"Documents" agrafée sur l'emballage pour effectuer des
réserves auprès du dernier transporteur, dans les délais
exigés.
soit sur leur chaise-support pour les tubes de
grande puissance à refroidissement Hypervapotron
ou Supervapotron,
soit sur une étagère anode en bas pour les tubes de
moyenne puissance refroidis à air.
Les tubes sont livrés avec des protège-céramiques
qui doivent rester en place pendant tout le temps du
stockage. La céramique des tubes doit rester propre. Si
par inadvertance la céramique était salie, i l est
formellement interdit d'utiliser une toile ou un tampon
métallique pour la nettoyer.
Avant la livraison, chaque tube THOMSON TUBES
ELECTRONIQUES a subi en usine une série complète
d'essais permettant d'assurer qu'il est conforme à sa
spécification.
A la première mise en service d'un tube, i l est
nécessaire d'effectuer les opérations suivantes:
1. Vérifier la continuité du filament et I'absence de
courts-circuits entre les électrodes.
2. Mettre en place le tube à I'aide du dispositif de
levage après avoir retiré le protège-céramique, en
évitant tout choc.
* 3. Dans le cas des Hypervapotrons, s'assurer que
le sens de circulation de l'eau de refroidissement
est bien respecté.
4. Appliquer la tension secteur de façon à ce que le
tube soit en sous-chauffage.
5. Laisser le tube en sous-chauffage pendant au
moins 30 minutes.
6. Appliquer la tension de chauffage comme
spécifié dans la notice ou suivant les instructions
spéciales de THOMSON TUBES
ELECTRONIQUES. Après 5 minutes, vérifier la
tension aux bornes du connecteur à I'aide d'un
voltmètre de classe 1,5 indiquant la valeur efficace
vraie (ferromagnétique, thermique ou numérique).
7. Laisser le filament allumé au moins 30 minutes,
puis appliquer les autres tensions.
8. Monter progressivement la puissance en porteuse,
puis appliquer progressivement la modulation.
19
INFORMATIONS - DEFINITIONS
CONDITIONS DE MESURE
l
--
----
- -
---
-- -
-- --
1. CARACTERISTIQUES GENB RALES
.
œ
I
I
r*
A*-
%
*
& &
&%&
"*
Le débit d'eau minimal correspond à la dissipation
anodique maximale pour une température de I'eau à
l'entrée de 55 C et une température de I'eau à la sortie
de 90 OC D'autres valeurs sont possibles à condition de
ne pas dépasser 100 OC pour la température de l'eau a
la sortie.
E l l e est d é f i n i e par T H O M S O N T U B E S
ELEcTRONIQUES pour chaque cas particulier de
V
:
fonctionnement.
Voir
paragraphe
recommandations sur I'utilisation du tube lors de la
conceDtion de l'équipement".
L a n o t i c e i n d i q u e u n e valeur a p p r o x i m a t i v e
correspondant au courant de chauffage dans le cas où
aucun autre réchauffement de la cathode n'intervient.
Les valeurs de tension et courant de chauffage sont
données à titre indicatif et uniquement pour la
prédétermination du transformateur de chauffage.
Les capacités interélectrodes sont mesurées dans un
montage spécialement conçu pour supprimer les
couplages parasites.
.
Le débit d'air minimal est défini dans les conditions
normales : niveau de la mer et température ambiante de
20 OC. Dans le cas du refroidissement de l'anode, le
débit d'air minimal indiqué correspond à la dissipation
anodique maximale.
Les températures maximales indiquees ne doivent
être dépassées en aucun point de l'enveloppe du tube:
collet, céramique, scellement céramique-métal.
I t . VALEURS LIMITES
)
La fiche technique indique pour les différents
paramètres (tension, courant, puissance, fréquence) la
valeur maximale à ne jamais dépasser pour une
application donnée, en général amplificateur RF
téléphonie.
Deux valeurs limites ne doivent jamais être atteintes
simultanément.
I
I
(
Cour ,,nt c a t l ~ o d i q ic! ~' t e
Valeur instantanée maximale du courant que la
cathode peut délivrer
Dissipation
Puissance dégradée sous forme de chaleur dans une
électrode, soit du fait du bombardement électronique.
soit par le rayonnement d'autres électrodes. Ces valeurs
dépendent des conditions d'utilisation.
En régime porteuse :
La dissipation d'anode correspond à la
puissance appliquée à l'anode diminuée de la
puissance HF compte non tenu des pertes.
La dissipation de grille-écran correspond au
produit de la tension continue par le courant
continu de grille-écran.
La dissipation de grille de commande
correspond approximativement au produit du
courant continu de grille par la tension crête de
grille (la cathode étant prise comme référence).
III. EXEMPLES DE FONCTIONNEMENT
L'exemple de fonctionnement cité indique les
performances du tube en réalisant un compromis entre
les différents paramètres tension, courant, puissance,
fréquence.
D'autres exemples de fonctionnement peuvent être
calculés, les différents paramètres devant rester à
l'intérieur des valeurs limites d'utilisation indiquées.
Puissance o' excitation
Produit d'intermodulation
Ensemble des signaux d'intermodulation produits par
la combinaison de deux signaux appliqués à l'entrée de
l'amplificateur. Ces deux signaux sont distants de 1100
Hz et 2450 Hz de la porteuse, leur niveau de sortie est
de - 6 dB par rapport à la puissance crête.
Le niveau du produit d'intermodulation est mesuré par
rapport à la puissance crête.
La puissance d'excitation dans le montage cathode à
la masse est égale à la somme de la puissance dissipée
sur la grille de commande et de la puissance fournie à
la polarisation.
TABLEAU il - Lcs t i i ,es de p ,issalil:e a grille poiil ddiodiffu~~ori
Fréquence (MHz)
TABLEAU III - C I J de pour le c h o i x des tiibes de p u i s s a n c e a
iqrille
pour
radiodiffusion
a - Tubes utilisés en amplification RF ou AF et en /ML ("PDM1')*
Amplificateur
Emetteur
RF
RF
Etage d'attaque**
Etage final HypervapotronB
1000 kW 1
OL
1 TH 362/TH 561
250 kW
OC
TH 562
TH 598
OM
100 kW
TH 598
OC
100 kW
Etage final Supervapotron
TH 362 / TH 562
O L I OM
500 kW
300 kW
OL / OM
TH 362 / TH 562
AF
IML
Etage final
1
/
TH 539
2 x TH 558
1
TH 5 3 9 i T H 558
TH 573
TH 581
TH 581rTH 555
2 x TH 532
2 x TH 532
TH 548
2 x TH 548
TH 573V
2 x TH 581V
TH 581
TH 581iTH 555A
IML= Impulsion Modulee en Longueur
PDM = Pulse Duration Modulation
Le choix du tube d attaque depend du mode de refroidissement desiré (Hypervapotronlair force)
"
b - Tubes util~séscomme amplificateurs BLU
Emetteur
Amplificateur
10 kW
5kW
1 kW
TH 399
TH 376
TH 349
IV. TUBES DE MAINTENANCE
THOMSON TUBES ELECTRONIQUES peut fournir également les tubes ci-après, pour lesquels des notices sont disponibles
RS 2022 CL
Sendetetrode
Fernseh-Bildsender,
Steuergitter-Schirmgitterbaçiççchaltung,negative Modulation
Sendetetrode
Verstarker fur Fernsehumsetzer mit gemeinsamer Bild- u n d Tonübefiragung,
Steuergitter-schirmgi~erbasisschaltung, Bild-Ton-LeistungsverhaItnis 10:1
Grenzdaten
Grenzdaten
Frequenz
Anodenspannung
Gitter-2-Spannung
Gitter-1-Spannung
Kathodenstrom
Kathodenspitzenstrom
Anodenverlustleistung
Gitter-2-Verlustleistung
Gitter-1-Verlustleistung
Frequenz
Anodenspannung
Gitter-2-Spannung
Gitter-1-Spannung
Kathodenstrom
Kathodenspitzenstrom
Anodenverlustleistung
Gitter-2-Verlustleistung
Gitter-1-Verlustleistung
MHz
kV1)
v1)
v
A
A
kW
W
W
Betriebsdaten
Betriebsdaten
220
220
220
MHz
Frequenz
18
12
MHZ~)
12
Bandbreite (-3 dB)
Bandbreite (- 1,2 dB)
716+0,63~)')12+0,53~)
1O
712+0,423) kW4)
MHZ~)
Ausgangsleistung bei Synchronpegel
9+0,36~) 6,6+0,2g3) 6,6+0,223) kW4)')
Ausgangsleistung bei Schwarzpegel
Anodenspannung
kV1)
5,2
4
4,8
900
800
800
Gitter-2-Spannung
- 85
- 75
- 75
V1)
Gitter-1-Spannung
V6)
Gitter-1-Spannung, Scheitelwert
bei ~ynchronpegel
Ug1rn SY 170
Anodenstrom bei Schwarzpegel
IA
sw
3,8
Gitter-2-Strom bei Schwarzpegel
IGZ
sw
120
Gitter-1-Strom bei Schwarzpegel
IGI
sw 50
Anodenspeiseleistung b.Schwarzpegel PBA SW 19,8
Treiberleistung bei Synchronpegel
Pl
46+6303)
Anodenverlustleistung b.Schwarzpegel PA
10,8
Gitter-2-Verlustleistung b.Schwarzpegel PGZSW 110
2
Gitter-1-Verlustleistung b.Schwarzpegel PG1
AnodenauBenwiderstand
RA
570
Freauenz
.
,,
RS 2022 CI
MHz
kV
v
v
A
A
kW
W
W
Ausgangsleistung bei Synchronpegel
3-Ton-lntermodulationsabstand
Anodenspannung
Gitter-2-Spannung
Gitter-1-Spannuna
Anodenstrom beiSchwarzpegel
Gitter-2-Strom bei Schwarzpegel
Sitter-1-Strom bei Schwarzpegel
Anodenspeiseleistung bei Schwarzpegel
Treiberleistung bei Synchronpegel
Ton-Treiberleistuna
,*.nodenverlustleistÜng bei Schwarzpegel
AnodenauBenwiderstand
MHz
MHz
kW1)
dB2)
kV
al~3
UA
v
u ~ 2
UGl
IA
SW
IG
SW
Z
IG
sw
I
PBA SW
Pl SY
Ton
PA SW
RA
n
Pegeldiagramm:
dB
Synchronpegel
O 1 !r-----ï
') Spannung g q e n Kathode gemessen
') AUS der Rbhrenkapazitat cg% errechnete Bandbreite
') übergangsleistung der Steuergitter-Schirmginerbasisxhaltung
4, Kre~sverluste
sind nicht berucksichtigt
') Schwarzpegel mit eingeblendeten Synchronimpulsen
): Fur Anodenstrom ohne Aussteuerung I n
= 1.6 A
) Notwendige Ausgangsleistung der Treiberstufe
)' Mit einer Stauchung des Synchronimpulses von etwa 5 % 1st zu rechnen Die L~near~tat
beim
262
i) Leistung am Senderausgang bei 90% Kreiswirkungsgrad,
) Abstand der grd~tenIntermoduiationsstorungvom
Synchronpegel innerhalb des Übertragungsbereiches
WmeSSen nach der Dreiton-Methode,mit Bildtrager.,
Tontrager- und Seitenbandfrequenz.Die Messung erfolgt
nach Pflichtenheft FTZ 176 Pfl2 der Deutxhen Bundes.
post mit verzerrungsfreiern Eingangssignei: fe: -8 d ~ .
fss: -16dB. f ~ -10
:
dB.
3, Ffir Anodenstrom ohne Aussteuerung 1
= 2,2A.
a
V3)
A
mA
mA
kW
W
W
kW
Sendetetrode
Sendetetrode
Heizung
Hochfrequenzverstarker,
B-Betrieb, Kathodenbasisschaltung
Heizspannung
Heizstrorn
Heizart: direkt
Kathode: Wolfram, thoriert
Grenzdaten
Frequenz
Anodenspannung
Gitter-2-Spannung
Gitter-1-Spannung
Kathodenstrorn
Kathodenspitzenstrorn
Anodenverlustleistung
Gitter-2-Verlustleistung
Gitter-1-Verlustleistung
Kennwerte
Ernissionsstrorn
bei UA= UG2= UG1= 300 V
11-Faktor des 2. Gitters
bei UA= 2 kv, UG2= 600 bis 1000 V,
I,=2A
Steilheit
bei UA= 2 kv, UG2= 800 V,
IA = 1,5 bis 2,5 A
KathodelGitter 1
KathodeIGitter 2
KathodeIAnode
Gitter l/Gitter 2
Gitter 11Anode
Gitter 2,Anode
Zubehor
') Mit Schirmplatte 0 50 a in der Sdiim7gineranschluBebenegernessen.
MHz
kV
v
v
A
A
kW
W
W
Betriebsdaten
Frequenz
Ausgangsleistung
Anodenspannung
Gitter-2-Spannung
Gitter-1-Spannung
Gitter-1-Spannung, Scheitelwert
Anodenstrom
Gitter-2-Strorn
Gitter-1-Strom
Anodenspeiseleistung
Treiberleistung
Anodenverlustleistung
Gitter-2-Verlustleistung
Wirkungsgrad
AnodenauBenwiderstand
Kapazitaten
Steckschlüssel für Rohrensicherung
Steckschlüssel für Rohrensicherung
Rohrensicherung
Rohrensicherung
Zugschalter für Rohrensicherung ,
Kontakffederkranze für:
Fnerer KathodenanschluB
AuBerer KathodenanschluB
Gitter-1-Anschlu8
Giner-2-AnschluB
'-
t
Bestell-Nr.
Q81-X2109
Q81-X2110
Q81-XI 407
Q81-XI410
Q81-XI311
') Kreisverfuste sind nicht berucksichtigt
)' Fur Anodenstrom ohne Aussteuerung I,,
= 0,4 A
3, Ohne Berucksichtigung einer Zh.sgtzdampfungim Gitterkreis
Y
MHz
kW1)
kV
v
$
rd
8,