Po wer-grid tubes Power-grid tubes f o r r a d i o & TV Thomson power-grid tubes Index of Thomson power-grid tubes and cavities Tube selection guide by band and power output Replacement tubes and cavities Tube and cavity data sheets Tube dimensions Quality performances of tetrode technologies High-power tetrode technology Thoriated-tungsten cathodes Grids Grid design considerations The classical solution The useful properties of ~ ~ r o b l o grids d@ Manufacturing Pyrobloc grids Anodes Forced-air cooling Hypervapotron cooling Ceramic insulators Power-grid tube performances in transmitters Radio transmitters 63 63 TV transmitters Amplification mode Gain 1,\ M O M S O N 1 TUBES ELECTRONIQUES -- - - Power-grid tubes I I Thomson Tubes Electroniques' RF-circuit assemblies 65 65 RF-circuit connectors TV-transmitter circuits Coupled c~rcu~ts Mechancal s ~ m p l ~ cand ~ t y standardizabon Matenals and technology Development and product~on 1 Operating information and recommendations Transportation, handling and storage I I 1 I I Entering a tube into service Tube ~nstallat~on F~rstuse of a new tube Voltage appi~cabonand settings Cavlty tun~ngaffer removal/ ~nstallabon Trançmitter design considerations Cathodes Hea ter voltage Regulation Application and shutdown of heater voltage Grids Anodes Cooling Hypervapotron cooling Forced-air cooling Air cooling and transmitter site Selection of a suitable cooling fan Basic principles of power-grid tubes The basic diode Triodes Basic mechanisms Characterist~ccurves Parameters character~z~ng tr~odeoperation Tetrodes Basic mechanisms Characteristic curves 1,\ THOMSON TUBES ELECTRONIQUES " % Power-grid tubes Power-grid tubes for radio & TV broadcasting G reater attention to the cost competivity of radio or TV stations has made cost-of-ownership of the broadcasting transrnifter a vital concern. Of the many competing technologies for the power amplifier. modern high-power tetrodes provide an ideal solution. New developments in tube capabilities have led to higher efficiencies, longer lifetimes, and increased cost effectiveness. Combined with their high reliability and the simplicity of amplifier design, tetrode transmiff ers also offer a larger bandwidth for future broadcasting techniques. Thomson Tubes Electroniques has been at the forefront of power-grid tube technology over many years. The company pioneered such developments as ~ ~ r o b l o cgrids " and ~ ~ ~ e r v a ~ ocoollng, t r o nand ~ ~more recently that of the high-power UHF tetrode. Thls techn~caledge is the result of the company's cont~nuedR& D investmenf ln gnd-tube technology. It also stems from a mot~vatedworkforce and rts hrghly qualrfied engineers and technlcians TheIr v~tal~ty has allowed the electron-tube industry to offer the best solut~onsfor today's and tomorrow's transmitters. The use of advanced analyttcal and computing tools as well as our modern product~on techniques has ensured that our extensive product range has kept Pace with evolving needs. The Power-Grid Tube Division of Thomson Tubes Electroniques is located at Thonon, overlooking Lake Geneva in the French Alps. The company's headquarters in the south-west of Pan's are home to the Sales and Marketing Teams. They are part of a worldwide customer support network dedicated to assisting you in correct tube choice, and ensuring you get the most from your Thomson tube. Thomson is also a leading player in more recent transmission techniques such as satellite news gathering and direct broadcasf satellites. The company's space traveling-wave tubes (TWTs) have been chosen for the latest broadcasting satellites including USDBS, Hispasat and Telecom 1 & 2. On the ground, Thomson3 TWTs and klystrons provide the performances required for video transmissions via earth stations and mobile uplinks. Thomson Tubes Electroniques is also engaged in the development of HDTV. The company offers high-definition projection CRTs for large-screen displays, bringing in the era of the electronic cinema. Furthermore, tetrodes provide the enhanced performances compatible with UHF HDTV transmission. Thomson Tubes Electroniques' long-term commitment to the radio and TV industry has made such technological progress possible. lt also guarantees the ongoing availability of our product line. Whatever your projects in radio or TV, you should be gaining from Thomson Tubes Electroniques, the leading edge in electron tubes. 3 Power-grid tubes Index Thomson power-grid tubes and cavities Reference -TH 225 TH 287 TH 289 - Band Power T y 250 W 10 kW 2kW Power is indicated as carrier power for rad10 tubes and peak-of-sync video for TV transm!tter TH 376 5 kW p e Cooling Page VHF VHF Radio FM UHF Tetrode Triode Tetrode Tetrode Tetrode air air air air air 12 8 8 8 8 UHF UHF VHF UHF UHF Tetrode Triode Tetrode Triode Triode air air air air air 8 8 13 8 14 UHF UHF UHF UHF UHF Triode Tetrode Triode Triode Tetrode air air air air air 8 8 15 16 UHF UHF UHF UHF UHF Triode Tetrode Triode Triode Triode air air air air air 17 8 8 8 18 UHF UHF FM UHF FM Planar triode Triode Tetrode Triode Tetrode air air air air air 19 FM FM FM UHF Radio Tetrode Tetrode Tetrode Tetrode Tetrode air air air air air VHF Radio VHF Radio FM Tetrode Tetrode Tetrode Tetrode Tetrode air air air air air VHF FM FM VHF Radio Tetrode Tetrode Tetrode Tetrode Tetrode air air air air air 8 8 20 8 21 31 f$ THOMSON TUBES ELECTRONIQUES Refe~nce Power Band TH 382 TH 390 TH 390 A TH 392 TH 393 11 kW 2 kW 2 kW 10 kW 4.4 kW UHF UHF UHF UHF UHF Tetrode Tetrode Tetrode Tetrode Tetrode air air air air air 32 8 8 8 33 TH 399 TH 476 TH 477 TH 478 TH 478 A 12 kW 200 kW 50 kW 250 kW 250 kW Radio Radio Radio Radio Radio Tetrode Triode Triode Triode Triode air water water water water 34 8 8 8 8 TH 479 TH 483 TH 485 TH 487 TH 491 B 30 kW 40 kW 100kW 110 kW 25 kW Radio Radio Radio Radio UHF Triode Triode Triode Triode Tetrode water water water water water 8 8 8 8 8 TH 4T1100 TH 4T4100 TH 504 C TH 504 V TH 520 2.3 kW 5 kW 300 kW 300 kW 70 kW Radio Radio Radio Radio Radio Tetrode Tetrode Triode Triode Tetrode air air water water water 8 8 8 9 9 Radio Radio UHF Radio Radio Tetrode Triode Tetrode Tetrode Tetrode water water water water water 35 9 36 37 38 Radio Radio Radio Radio FM Tetrode Tetrode Tetrode Tetrode Tetrode water water water water water 9 9 39 9 9 UHF Radio Radio Radio Radio Tetrode Tetrode Tetrode Tetrode Tetrode water water water water water 40 9 9 41 42 VHF Radio UHF VHF Tetrode Tetrode Tetrode Tetrode water 43/44 water water water 45 46 47 Type 1 I TH 561 TH 562 TH 563 TH 571 A 1 r,\ THOMSON TUBES ELECTRONIQUES 15 kW 12 kW 44 kW 41 kW Cooling_-Page 5 Power-grid tubes i IIYldLIUI I Thyratron Thyratron Cavity 9 Cavity Cavity new 20 21 Cavity 15 TH 18324 Cavity 13 TH 18326 TH 18327 TH 18346 Cavity Cavity Cavity TH 18362 Cavity 14117 TH 18363 Cavity TH 18462 Cavity Cavity 16125 18119 Cavity TH 18482 TH 18526 27 28 24 32 43 TH 18527 Cavity Cavity TH 18550 Cavity TH 18563 Cavity TH 18565 Cavity 52 TH 18582 Cavlty 51 TH 18665 Cavity 33 47 46 36140 MOMSON TUBES ELECTRONIQUES Po wer-grid tubes - - Tube selection guide Band and power output Reference Power TYpe TH 326 TH 308 TH 328 TH 338 TH 339 TH 327 TH 527 TH 347 TH 547 TH 393. TH 593 TH 382 TH 582 TH 563 50 W 110 w Il0 W 220 W 220 W 550 W 1 kW 2 kW 2 kW 44kW 44kW 11 kW 22 kW 44 kW Triode Triode Triode Triode Planar triode Tetrode Tetrode Tetrode Tetrode Tetrode Tetrode Tetrode Tetrode Tetrode air air air air air air water air water air water air water water VHF Television TH 225 TH 298 TH 375 TH 361 TH 561 TH 371 TH 571 A 250 W 2.2 kW 10 kW 15 kW 15 kW 21 kW 41 kW Tetrode Tetrode Tetrode Tetrode Tetrode Tetrode Tetrode air air air air water air water FM Radio TH 341 TH 344 TH 373 TH 345 TH 343 TH 346 I O kW 10 kW 10 kW 22 kW 30 kW 60 kW Tetrode Tetrode Tetrode Tetrode Tetrode Tetrode air air air air air air Tetrode Tetrode Tetrode Tetrode Tetrode Tetrode Tetrode Tetrode Tetrode Tetrode Tetrode Tetrode Tetrode Tetrode Tetrode water air air water water water water water water water water water water water UHF Television - AM Radio LIMISW - Power a rndrcated on the carrier for rad10 tubes and peak-of-sync video for T V tubes 1,\ THOMSON TUBES ELECTRONIQUES TH 349 TH 598 TH 376 TH 399 TH 561 TH 562 TH 532 TH 521 TH 581 TH 555 A TH 537 TH 573 TH 558 TH 576 TH 539 Cooling Page 12 13 30 27 43 28 47 20 22 29 23 21 24 air 7 Power-grid tubes - - - Replacement tubes and cavity The following products continue to be offered as replacements for existing transmitters, thus guaranteeing availability. They are not proposed for new designs, but should you require further information on their performances, do not hesitate to contact Thomson Tubes Electroniques. - Reference --Power \ . - Power is indicated as carrier power for radio tubes and peak of sync video for T V transmitter tubes. Band Type Cooling -- TH 287 TH 289 TH 289 MA TH 290 TH 293 I O kW 2kW 3kW I O kW 2kW VHF Radio FM UHF UHF Triode Tetrode Tetrode Tetrode Tetrode air air air air air TH 294 TH 306 TH 308 B TH 313 TH 316 400 W 25 W 250 W 5kW 35 W UHF UHF UHF UHF UHF Triode Triode Triode Tetrode Triode air air air air air TH 331 TH 336 TH 337 TH 340 TH 342 1 kW 25 W 200 W 220 W 500 W UHF UHF UHF UHF UHF Tetrode Triode Triode Triode Triode air air air air air TH 354 TH 360 TH 362 TH 369 TH 374 10 kW 12 kW 12 kW 5kW 30 kW VHF Radio Radio FM FM Tetrode Tetrode Tetrode Tetrode Tetrode air air air air air TH 390 TH 390 A TH 392 TH 476 TH 477 2kW 2kW lOkW 200 kW 50 kW UHF UHF UHF Radio Radio Tetrode Tetrode Tetrode Triode Triode air air air water water TH 478 TH 478 A TH 479 TH 483 TH 485 250 kW 250 kW 30 kW 40 kW 100 kW Radio Radio Radio Radio Radio Triode Triode Triode Triode Triode water water water water water TH 487 TH 491 B TH 4T1100 TH 4T4100 TH 504 C 110 kW 25 kW 2.3 kW 5 kW 300 kW Radio UHF Radio Radio Radio Triode Tetrode Tetrode Tetrode Triode water water air air water a - ,,\ THOMSON TUBES ELECTRONIQUES 1 Po wer-grid tubes Power -. 300 kW 70 kW 250 kW 300 kW 300 kW Band - -_Type.._ - Cooling Radio Radio Radio Radio Radio Triode Tetrode Triode Tetrode Tetrode water water water water water Radio FM Radio Radio Radio Tetrode Tetrode Tetrode Tetrode Tetrode water water water water water Radio Radio Radio UHF UHF Tetrode Tetrode Tetrode Tetrode Tetrode water water water water water Thyratron Thyratron Thyratron Cavity 1 Gb THOMSON TUBES ELECTRONIQUES FMNHF tetrode i Output power 250 W up to 500 MHz General characteristics Cathode ........................................................................................ oxide Heating(1) .................................................. direct, dc or single phase lnterelectrode capacitances, approx.: Ground/cathode connection: .......... .............................1 5 7 pF input ..................... . . ....... output .............................................................................. 4.5 pF ....0.04 pF feed-through ......................................................... . . Groundlgrid connection: input .............................. .......... ......................................... 13 pF output ....................... . . .............................................. 4.5 pF feed-through ................................................................ 0 0 pF Amplification factor, average ......................... . ................................ 5 Transconductance (la = 0.2 A, Vg2 = 250 V) ..........................12 mA1V Operating position ......................................................................... anY Weight, approx..................... . ................................................. 140 g Dimensions ................................................................... s e page 55 Anode, electrode terminal and ceramic cooling (2): type ......................................................................... forced air temperature on the tube, max. ............................................250 OC TYpical operation carrier conditions Maximum ratings Anode voltage ...................................... 2 kV Control-grid voltage .............................-250 V Screen-grid voltage ...............................400 V Peak cathode current .........................250 mA Anode dissipation ................................250 W Control-grid dissipation ............................2 W Screen-grid dissipation .......................... 12 W (1) Thomson Tubes Electroniques defines the operating voltage according to each particular situat~on.As an indication for equipment design purposes only, a heater voltage of 6 Vproduces a heating current of 2.6 A. (2) Values for cooling given for maximum anode dissipahon. output power 250 W Frequency 500 MHz 2 kV Screen-grid voltage 250 V Control-grid bias voltage - 90 Anode cubent 250 Anode voltage Screen-grid current 10 Control-grid current 1O mA <! THOMSON TUBES ELECTRONIQUES FMNHF tetrode i Output power up to 2.2 kW peak-of sync in common amplification 3.75 kW in sound carrier amplification 3 kW in FM radio transmitters General characteristics Cathode ...................................................................thoriated tungsten Heating (1) ..................................................................................direct lnterelectrode capacitances, approx.: cathode-control grid .............................................................4 0 pF ........................75 pF control grid-screen grid .............................. . 11.5 pF screen grid-anode ............................................................... Amplification factor, average .............................................................. 7 Transconductance (la = 1.5 A, Vg2 = 600 V) ..........................40 m A N Operating position ...................................... -ciaI Weight, approx. .............................................................................. 2 kg Dimensions ................................................................s e page 55 Anode cooling ( 2 ).................................................................. f o r c e air air flow, min. ......................................................................5 mJ/mn corresponding pressure drop ...........................................5 mbar outlet air temperature, less than ..................................... 100 OC Electrode terminal and ceramic seal cooling type .................................................................................. forced air temperature on the tube, max .............................................. 250 "C Maximum ratings Frequency ........................................ 300 MHz .......... 5 kV Anode voltage ........................ . Anode current .............................. ....... 2.5 A Anode dissipation ................................... 5 kW Control-grid dissipation ...................... ..40 W Screen-grid dissipation ......................... 60 W ( 1 ) Thomson Tubes Electroniques dehnes the operatmg voltage accordmg to each particular situat/on As an indlcabon for equipment design purposes only, a heater voltage of 6 V produces a heaiing current of 50 A (2) Values for cool~nggiven for max~mumanode d~ssipation Common Sound amplification only Typical operation at 178 MHz TV operation in the matched cavity TH 18324A TH 18324A - Sound carrier output power Peak-of-sync output power - 1 d B bandwidth - 3 d B bandwidth > 300 kW kW MHz kHz 23 dB dB 3.75 3 2.2 8 Intermodulation products - 48 Gain 14 Anode voltage 4.5 Screen-grid voltage 500 Anode current, with signal 1.35 Screen-grid current 1O Control-grid current negligible Anode current at zero signal 0.6 matched circuit assembly FM radio 4 16.5 5 5 500 1.5 50 negligible 0.6 400 0.8 20 35 0.1 kV V A mA mA A ---. l For UHF-TV transmitters and translators (Band III) Operating frequency ....................................................178 to 227 MHz Dimensions ....................................................760 x 278 x 178 mm Weight, approx (without tube) .......................................:...........25 kg RF connections: input ....................................................................... f e m a e type N output .......................................standard EIA rigid coaxial line 718" Cooling ..................................................................................forced air I,\ THOMSON TUBES ELECTRONIQUES 13 / UHF triode Output power upto 110 W peak-of sync in common amplification General characteristics Cathode ...................................................................................... oxide Heating (1) ...............................................................................indirect lnterelectrode capacitances, approx.: cathode-grid ........................................................................ 16 pF cathode-anode ................................................................... 0 . 1 pF grid-anode ...................................................................... 7.3 pF Amplification factor, average ............................................................ 80 Transconductance (la = 0.25 A) ......................................... 45 mA/V Operathg position .......................................................................... any Weight, approx.. ........................................................................... g Dimensions .....................................................................S page 55 Anode cooling (2)....................................................................... air air flow, min. ...................................................................... 450 Ilmn corresponding pressure drop ...........................................O. mbar outlet air temperature, max. .................................................... OC Electrode terminal and ceramic seal ~00ling type ............................................................................... forced air 5 0 "C temperature on the tube, max. ............................................. : Maximum ratings Frequency ......................................1000 MHz Voltage .................................................2.2 kV Anode current ........................................0.6 A Anode dissipation ................................700 W (1) Thomson Tubes Electroniques defines the operaling voltage according to each particular situation As an indicat~onfor equipment design purposes only a heater voltage of 6 3 V produces a heating current of 6 A (2) Values for cooling given for maximum anode dissipation Common amplification T~~ical at 780 MHz I in the matched cavity TH 18362 Peak-of-sync output power - 1 dB bandwidth 110 W 10 MHz 0.2 A Intermodulation products Gain Anode voltage Grid voltage Anode current, with signal Anode current at zero signal I I I I TH 18362 matched circuit assembly dm& - .-A- .z--- For UHF-TV transmitters and translators (Bands IV and V) 460 to 860 MHz Operating frequency .................................................... 571 .5 x 260 x 162 mm ....................................................... Dimensions O kg ...................................................... Weight, approx (without tube) RF connections: input .................................................................... female, type BNC output .........................: ............................................. female, type N Cooling ............................................................................... forced air 14 y # y THOMSON TUBES ELECTRONIQUES UHF triode i Output power up to 50 W peak-of sync in common amplification General characteristics Cathode ......................................................................................~oxide Heating (1) ................................................................................... lnterelectrode capacitances, approx.: cathode-grid ......................................................................... 22 pF cathode-anode ............................................................... 0 0 5 pF grid-anode ............................................................................. 3 9 PF Amplification factor, average ..........................................................250 Transconductance (la = 0.15 A) .............................................80 m A N Operating position .......................................................................... anY Weight, approx. ................................................ . . . . . . . . . . . . . 170 . g Dimensions ....................................................................... s e page 55 Anode cooling (2) ...................................................................foced air air flow, min. ...................................................................... 280 I/mn corresponding pressure drop ........................... . . .........0 5 mbar outlet air temperature, max. ................................ . . ...........0 0 OC Electrode terminal and ceramic seal cooling air type ....................................................................................... . ..............150 "C temperature on the tube, max. .......................... Maximum ratings Frequency .................................. 1000 MHz Voltage. ............................ 2 kV Anode current ........................... ... 250 mA Anode dissipation ..............................-270 W ( 1 ) Thomson Tubes Electroniques defines the operating voltage according to each par?icular Situabon As an ~ndicationfor equipment design purposes only, a heater voltage of 5 Vproduces a heating current of 2 A. (2) Values for cooling given for anode dissipation of 200 W. Common amplification T Y P ~ operation c~~ at 780 MHz in the matched cavity TH 18261 Peak-of-sync output power 50 W - 1 dB bandwidth 1O MHz - 53 dB Gain 20 dB Anode voltage 1.8 kV intermodulation products Grid voltage Anode current, with signal Grid current Anode current at zero signal TH 18261 negligible mA 140 matched circuit assembly For UHF-TV transmitters and translators (Bands IV and V) Operating frequency ....................................................470 to 960 MHz Dimensions ..........................................................460 x 240 x 150 mm Weight, approx (without tube) ........................................................6 kg RF connections: input .............................................................. f e m a e type BNC output .......................................................................female, type N Cooling ...................................................................................foced air . . UHF tetrode Output power up to 550 W peak-of sync in common amplification up to 1.2 W in sound carrier amplification General characteristics Cathode ..................................................................t h o a e d tungsten Heating (1 ) ......................................... .........................................direct lnterelectrode capacitances, approx.: cathode-control grid ............................................................... O PF control grid-screen grid .......................................................PF screen grid-anode ................................................................. 8,2 pF Amplification factor, average ............................................................ 7 Transconductance (la = 1.5 A, Vg2 = 400 V) .......................... 40 m A N Operating position .................................................................... veriical Weight, approx .......................................................................... 2.3 kg page 55 Dimensions ................................................................... ....................................... forced air Maximum ratings Anode cooling (2)................... . . air flow, min. ...................................................................... 2 m3/mfl Frequency ....................... .......1000 MHz . . . .....................2 mbar Anode voltage ...................... corresponding pressure drop .................... ........ 5 kV . . . . ............0 0 "C Anode current .......................... . ......... 2 A outlet air temperature, max. ............................ . . Anode dissipation ................................4.5 kW Electrode terminal and ceramic seal cooling Control-grid dissipation ............................5 W air type ................................................................................. Screen-grid dissipation ..........................25 W temperature on the tube, max. .............................................250 O C (1) Thomson Tubes Electroniques defines the operating voltage according to each particular situation. As an indication for equjpment design purposes only, a heater voltage of 6 V produces a heating currenf of 34 A (2) Values for cooling given for anode dissipation of 2 kW. Common amplification Typical operation at 800 MHZ in the matched cavity TH 18363 ~eak-of-syncoutput power Sound carrier output power - 1 dB bandwidth Intermodulation products Anode voltage Screen-grid voltage Anode current, with signal Screen-grid current Control-grid current Anode current at zero signal TH 18363 Sound only 550 1O 1200 1O - 54 15.5 15.5 3.5 400 0.65 2 negligible 0.5 4 400 1 5 negligible 0.5 W W MHz dB dB kV V A mA A matched circuit assembly For UHF-TV transmitters and translators (Bands IV and V) Operating frequency .......................... . ....................470 to 860 MHz Dimensions ..................................................... 644 x 268 x 200 mm 20 kg Weight, approx (without tube) ................................................... RF connections: input .................................... ...................................f e m a e type N output .. EIA 718" Cooling .............................................................................forced air 16 THOMSON TUBES ELECTRONIQUES UHF triode i Output power up to 110 W peak-of sync in common amplification General characteristics -Cathode ..................................................................................... oxide Heating (1) ................................................................................ indirect lnterelectrode capacitances, approx.: cathode-grid ........................................................................... 19 pF cathode-anode ..................................................................0.07 pF grid-anode ............................................................................. 8 2 pF Amplification factor, average ...........................................................180 Transconductance (la = 0.4 A) ..............................................85 m A N Operating position ..........................................................................anY Weight, approx ............................................................................. 950 g Dimensions ....................................................................... s e page 55 Anode cooling (2) ............................................................... f o r c e air air flow, min. .................................................................... 470 I/mn corresponding pressure drop ..................... ................ 1 mbar outlet air temperature, max. ......................... ..................... 0 0 " C Electrode terminal and ceramic seal cooling type ............................................................................... f o r c e air . ............... 250 OC temperature on the tube, max. .................... . . . Maximum ratings Frequency .....................................,1000 MHz Anode voltage ...................................... 2.2 kV Anode current ...................................... 0.6 A .....750 W Anode dissipation ................... . . . (1) Thomson Tubes Electroniques defines the operating voltage accor8ng fo each paificular situation. As an ~ndicatronfor equipment design purposes only. a heater voltage of 5.5 V produces a heahng current of 5.4 A (2) Values for cooling given for maximum anode dissipation. Common amplification T~~ical at 780 MHz in the matched cavity TH 18362 Peak-of-sync output power 110 W 1O MHz - 52 dB Anode current, with signal 0.43 A Anode current at zero signal 0.4 A - 1 dB bandwidth Intermodulation products Gain Anode voltage Grid voltage i I i r i TH 18362 matched circuit assembly For UHF-TV transmitters and translators (Bands IV and V) Operating frequency .................................................... 460 to 860 MHz Dimensions ................................................... 5 7 . 5 x 260 x 162 mm Weight, approx (without tube) ...................................................1O kg RF connections: input .................................................................... f e m a e type BNC output ...................................................................... f e m a e type N Cooling .................................................................................forced air S FI FCTRONIQUES 1 1 17 UHF tetrode a Output power up to 550 W peak-of sync in common amplification up to 1.2 W in sound carrier amplification General characteristics Cathode ................................................................. thoriated tungsten Heating (1) ...................................................................................dire~t lnterelectrode capacitances, approx.: cathode-controlgrid ............................................................... 0 pF control grid-screen grid ......................................................... 50 pF screen grid-anode................................................................. 8.2pF Amplification factor, average .............................................................. 7 Transconductance (la = 1.5A, Vg2 = 400 V) .......................... 40 m w Operating position .................................................................... v€?t?icaI Weight, approx ............................................................................ 2.3 kg Dimensions .......................................................................See page 55 Anode cooling (2)................................................................ forced air Maximum ratings ...... .................................. 2 m3/mn Frequency ..................................... air flow, min. ..................... .IO00MHz 5 kV corresponding pressure drop .............................................. 2 mbar Anode voltage ......................................... OC Anode current .......................................... 2 A outlet air temperature, max. .................................................lOO Anode dissipation............................... 4.5kW Electrode terminal and ceramic seal cooling type ............................................................... . . . . . . . .forced air Control-grid dissipation ............................5 W "C Screen-grid dissipation .......................... 25 W temperature on the tube, max. ............................................ ( 1 ) Thomson Tubes Electroniques defiries the operating voltage according to each parttcular situabon As an indication for equipment design purposes only, a heater voltage of 6 V produces a heating currenf of 34 A. (2) Values b r cool~nggiven for anode dissrpalion of 2 kW Common amplification Typical operation at 800 MHz in the matched cavity TH 18363 ~eak-of-syncoutput power 550 1200 Sound carrier output power - 1 dB bandwidth 10 1O - 54 lnterrnodulation products W W MHz dB 15.5 dB 3.5 4 Screen-grid voltage 400 400 Anode current, with signal 0.65 1 2 5 negligible 0.5 kV V A mA 15.5 Anode voltage Screen-grid current Control-grid current negligible 0.5 Anode current at zero signal TH 18363 Sound only matched circuit assembly ,_*. .- For UHF-TV transmitters and translators (Bands IV and V) Operating frequency .................................................470 to 860 MHz 644 x 268 x 200 mm Dimensions ........................................................ Weight, approx (without tube) ......................................................20 kg RF connections: input ........................................................................femae type N output ................................................................. standard EIA 718" Cooling................................................................................. foced air A t . THOMSOM TUBES ELECTRONIQUES UHF triode Output power up tu 220 W peak-of sync in common amplification General characteristics Cathode ....................................................................................oxide Heating (1) .......................................................................indirect lnterelectrode capacitances. approx.: cathode-grid ........................................................................... 16 pF cathode-anode ............................................................... 0 13 pF grid-anode ............................................................................. 7.3 pF Amplification factor, average ...........................................................80 Transconductance (la = 0.25 A) ..............:............................ 45 m m Operating position ........................................................................ anY Weight, approx. ........................... . ........................................... 1.2 kg page 55 Dimensions .......................................................................... Anode cooling (2) ......................................................................... air air flow, min. .................................................................... 1250 Ilmn corresponding pressure drop ...........................................4.5 mbar outlet air temperature, max. ............................................... 0 0 OC Electrode terminal and ceramic seal cooling type .................................................................................. forced air 250 OC temperature on the tube, max. ......................................... I Maximum ratings Frequency ......................................1000 MHz ........2.5 kV Anode voltage ......................... . . Anode current ........................................0.6 A Anode dissipation .............................. 1.2 kW ( 1 ) Thomson Tubes Electroniques defines the operahng voltage according to each pa~ticularsituation As an ind~cahonfor equipment design purposes only, a heater voltage of 6 3 V produces a heating current of 6 A (2) Values for cooling given for anode dissipation of 1 kW Common amplification T~~ical at 780 MHz in the matched cavity TH 18462 220 W - 1 d B bandwidth 1O MHz lntermodulation products ,52 dB 0.4 A Peak-of-sync output power Gain Anode voltage Grid voltage Anode current, with signal Anode current at zero signal I I 1, 1 I TH 18462 --.&::y-.. &-;a- matched circuit assembly For UHF-TV transmitters and translators (Bands IV and V) ......................460 to 860 MHz Operating frequency .................. . . 5 7 .5 x 260 x 162 mm Dimensions .................................................. Weight, approx (without tube) ..................................................... kg RF connections: input ......................... . .................................. f e m e , type BNC . .......................................... female, type N output ........................ .............................................................. forced air Cooling ............... . 18 I - 1,\ IHOMSON TUBES ELECTRONIQUES UHF triode up to 220 W peak-of sync in common amplification General characteristics .. ..oxide Cathode ................................................................... ...... Heating (1) .............................................................................. indirect lnterelectrode capacitances, approx.: cathode-grid ......................................................................... 19 pF cathode-anode ..................... . . ...................................... 0 0 7 pF grid-anode ...................................................................... .7.3 pF Amplification factor, average ........................................................ 180 5 mA/V Transconductance (la = 0.4 A) ...................................... 8 Operating position .......................................................................... anY Weight, approx ............................................................................ 1.2 kg s e page 55 Dimensions ................................................................... Anode cooling (2)................................................................ f o r c e air air flow, min. .................................................................. 1250 Ilmn corres~ondina d r o ~ max , ............................... ,425 mbar - ,~ r e s s u r e outlet air temperature, max. ........................................... 100 OC Electrode terminal and ceramic seal coolinq type ............................................................................... f o r c e air 250 OC temperature on the tube, max. ............................................. Maximum ratings Frequency ...................................... 1000 MHz Anode voltage ......................................2.2 kV ...........0.6 A Anode current ........................ . Anode dissipation ........... . . ..............1.2 kW ( 1 ) Thomson Tubes Electron~quesdefines the operating voltage according to each pati~cularsituation As an indication for equlpment design purposes only, a heater voltage of 5 5 V produces a heatlng current of 5 5 A (2) Values for cool~nggiven for anode dissipabon of 1 kW Common amplification T ~ ~ i cOperation al at 780 MHz in the matched cavity TH 18462 I I I I I 1 TH 18462 Peak-of-çync output power 220 W 1O MHz - 52 dB Gain 20 dB Anode voltage 2.0 kV Grid voltage -9 V Anode current, with signal 0.45 A Anode current at zero signal 0.35 A - 1 dB bandwidth lntermoduiation products matched circuit assembly For UHF-TV transmitters and translators (Bands IV and V) .....460 to 860 MHz Operating frequency ........................................ . . Dimensions ............................................... 571 .5 x 260 x 162 mm Weight, approx (without tube) ...................................................... 10 kg RF connections: input ....................................................................f e m a e type BNC output .......................................................................f e m a e type N Cooling ................. . ..............................................................f o r c e air L b THOMSON TUBES ELECTRBNIOUES l ---A., %.+ 19 FM tetrode i Output in power up to 10 kW FM r a d i o t r a n s m i t t e r s General characteristics Cathode .................................................................. horiated tungsten Heating (1) ....................................................direct, dc or single phase lnterelectrode capacitances, approx.: cathode-control grid .......................................................... 2 pF control grid-screen g r d . ..............................................135 PF screen grid-anode ............................................................... '9 PF Amplificafion factor, average ........................................................... 5.5 Transconductance (la = 0.15 A, Vg2 = 500 V) ........................ 60 mAiV Operating position .................................................................. ..ve"cal Weight, approx ........................................................................... 3.5 kg Dimensions .....................................................................S page 55 Anode cooling (2) ............................................................. forced air air flow, min. .................................................................. ....6 m3/mn corresponding pressure drop ........................................1.5 mbar outlet air temperature, max. ...............................................100 OC Electrode terminal and ceramic seal ~ 0 0 l i n g type .................................................................................. forced air 250 OC temperature on the tube, m a x ............................................. Maximum ratings Frequency ........................................120 MHz Anode voltage .........................................8 kV Anode current ..........................................6 A Anode dissipation ...................................6 kW Control-grid dissipation ..........................50 W Screen-grid dissipation ........................150 W (1) Thomson Tubes Electroniques defines the operating voltage according to each particular situabon As an indication for equipment design purposes only, a heater voltage of 6 5 Vproduces a heating current of 85 A (2) Values for cooling given for maximum anode dissipation TH18108K TH 18108G Grounded-grid Grounded-cathode operation operation TYpical ope ration at 108 MHz in the matched cavity TH 18108 1O 1O kW 300 300 kHz Gain 17 21 dB Anode voltage 7 6.5 kV 400 output power - 0.2 d~ bandwidth Screen-grid voltage v Anode current, with signal 2 500 1.95 Screen-grid current 60 70 mA Control-grid current 30 30 mA 0.25 0.05 A Anode current at zero signal A l TH 1810 8 M H 18108K matched circuit assemblies For FM radio transmitters 87 to 108 MHz Operating frequency ...................................................... 555 x 455 x 241 mm ..................................... Dimensions. TH 18108G 561 x 340 x 241 mm Dimensions, TH 18108K ...................................... . . .38 kg Weight, approx (without tube), TH 18108G .................- Weght, approx (without tube), TH 18108K .................................. 25 kg RF connections: input ....................................................................... fernale. type N output . . . . . . . .,........................................ EIA standard 1 518'' Cooling ................................................................................forced air ,,\ THOMSON TUBES ELECTRONIQUES FM tetrode Output power up to 30 kW in FM radio transmitters General characteristics Cathode .................................................................. thoriated tungsten direct, dc or single phase Heating (1) .................................................... lnterelectrode capacitances, approx.: cathode-control grid ............................................................. 110 pF control grid-screen grid .......................................................2 5 pF screen grid-anode ..................................................................28 pF Amplification factor, average .............................................................. 7 Transconductance (la = 2 A, Vg2 = 500 V) ...........................1O0 m A N Operating position ..................................................................vertical Weight, approx. ........................ .................................................. 6 kg Dimensions ....................................................................... s e page 55 Anode cooling (2)...................................................................forced air air flow, min. ....................................................................4 m3tmn corresponding pressure drop ..............................................5 mbar O "C outlet air temperature, max. ................................................. Electrode terminal and ceramic seal cooling type ..................................................................................forced air temperature on the tube, max. ........................................... 250 OC Maximum ratings Frequency ........................................ 120 MHz Anode voltage ...................................... 1O kV Anode current ........................................ 7 A Anode dissipation ...............................8 kW Control-grid dissipation ........................100 W .Screen-grid dissipation ........................300 W ( 1 ) Thomson Tubes Electroniques defines the operating voltage according to each particular situation. As an indication for equipment design purposes only, a heater voltage of 7.6 Vproduces a heating current of 120 A. (2) Values for cooling given for anode dissipation of 12 kW Example 1 Example 2 20 30 kW 300 300 kHz Gain 17 18 dB Anode voltage 8.5 9.5 kV Screen-grid voltage 500 600 V Anode current, with signal 2.9 4.2 A Screen-grid current 120 220 mA Control-grid current 30 4 mA 0.05 0.5 A Grounded-grid operation TYpical operation at 108 MHz in the matched cavity TH 18230G output power - 0.2 dB bandwidth Anode current at zero signal TH 182306 matched circuit assembly For FM radio transmitters Operating frequency ................................................... 87.5 to 108 MHz 800 x 580 x 483 mm Dimensions .......................................................... 63 kg Weight, approx (without tube) .................................................... RF connections: input .........................................................................femae type N output ............................................................. EIA standard 3 118" Cooling ...................................................................................f o r c e air TH 343 FM tetrode rn Output power in FM radio transmitters b- i a* )*V///Ib\\i General characteristics Cathode .................................................................. thoriated fungsten Heating (1) .................................................direct. dc or single phase lnterelectrode capacitances, approx.: cathode-control grid ............................................................110 PF control grid-screen grid .......................................................215 PF screen grid-anode ..................................................... 2 8 PF Amplification factor, average ..................................................7 Transconductance (la = 2 A, Vg2 = 500 V) ...........................100 m A N Operating position ...................................................................~eflical Weight, approx ............................................................................... 6 kg Dimensions .................................................................. See page 55 Anode cooling (2) ................................................................... forced air air flow, min. .................................................................. 14 m3/mn corresponding pressure drap .............................................. 5 mbar outlet air temperature, max. ................................................. 100 OC Electrode terminal and ceramic seai cooling type ..................................................................... air temperature on the tube, max. .............................................250 O C , . * a .. e V ' Maximum ratings Frequency ..................................... 120 MHz Anode voltage . ...,... ........................ 1 0 kV 7A Anode current .......................................... Anode dissipation ................................. 18 kW Control-grid dissipation ....................100 W Scieen-grid dissipation ....................3 0 0 ( 1 ) Thomson Tubes E/ectroniques defines the opeiating voltage according to each paflicular situalon, an for eq~ipmentdesign purposes only, a heater voltage of 7.6 V produces a heating current of 120 A (2) values for cooling given for anode dissipation of 12 kW. Example 1 Example 2 output power 20 - 0.2 dB bandwidth 300 30 300 kHz Gain 17 18 dB Anode voltage 8.5 9.5 kV Screen-grid voltage 500 600 v Anode current, with signal 2.9 4.2 A Screen-grid current 220 Control-grid current 120 30 4 mA mA Anode current at zero signal 0.05 0.5 A Grounded-grid operation TYpical operation ât 108 MHz in the matched cavity TH 182306 TH 182306 matched circuit assembly For FM radio transmitters 81.5 to 108 MHz Operating frequency ................................................... O X 580 X 483 mm .......................................................... Dimensions 63 kg Weight, approx (without tube) ...................................................... RF connections: input ................................................................... ......fernale,type N output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . standard 3 118" Cooling ......................................................................................... air kW FM tetrode i Output power up to 15 kW in FM radio transmitters 1 "JTHIIMSON TUBES ELECTRONIOUES General characteristics Cathode .................................................................. thoriated tungsten Heating (1) ....................................................................direct, dc or ac lnterelectrode capacitances, approx.: cathode-control grid ............................................................... 95 pF control grid-screen ................................................................. 76 pF screen gïid-anode .................................................................. 22 pF 1 .......8 Amplification factor, average ...................................................... Transconductance (la = 3 A, Vg2 = 800 V) .............................53 mA/V Operating position ............................................................................ Weight, approx............................................................................ 6.7 kg Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page . 55 Anode coollng (2) ................................................................. forced air air flow, min. ....................................................................12 m3/mn corresponding pressure drop .............................................. 9 rnbar outlet air temperature, max. ................................................ 1O "C Electrode terminal and ceramic seal cooling type ................................................................................. forced air 220 OC ............................................. temperature on the tube, max. (250 "C on grid connections) Maximum ratings Frequency ........................................ 120 MHz Anode voltage ........................................ 9 kV Anode current ..........................................6 A Anode dissipation ...............................1 kW Control-grid dissipation ........................100 W Screen-grid dissipation ........................ 300 W ( 1 ) Thomson Tubes Eiectroniques deiines the operating voltage according 10 each parlicular situation As a n ~ndicationfor equ~pmenldesrgn purposes only a healer voltage ol 9 5 V produces a heating cufrenl of 80 A (2) Values for c o o l i n g g i v e n for m a x i m u m a n o d e diss~pation Example 1 Example 2 15 1O kW - 0.2 d B bandwidth 300 23 300 23 kHz CIB Anode voltage 8.5 7.5 kV Screen-grid voltage 750 700 V Control-grid bias voltage - 90 - 100 v Anode current, with signal 2.5 1.9 A Screen-grid current 250 mA Control-grid current 30 180 20 " T y ~ i c aoperation l at MHz Class B amplification, Grounded-cathode operation '* 1i 22 output pawer mA THOMSON TUBES ELECTRONIQUES FM tetrode i Output power up to 22 kW in FM radio transmitters iHOIWI ELmwIoUEs TUEES < -u, General characteristics Cathode ..................................................................t h o r i a e tungsten Heating (1) ........................................................................ dc or ac lnterelectrode capacitances, approx.: cathode-control grid ............................................................. 82 pF control grid-screen grid ........................ . . ....................128 pF screen grid-anode ................................................................ 21 pF Amplification factor, average .............................................................. 7 Transconductance (la = 3 A, Vg2 = 800 V) ........................... 80 m A N Operating position .................................................................... vertical Weight, approx. ..............................................................................7 kg Dimensions .......................................................................see page 55 Anode cooling (2)................................................................... f o r c e air air flow, min. ....................................................................22 m3/mn corresponding pressure drop ...................................... 9 mbar outlet air temperature, max. O OC Electrode terminal and ceramic seal cooling type ................................................................................... air 220 OC temperature on the tube, max. ........................................ (280 O C on heater connections) ........................................... at 'O8 MHz Grounded-grid operation Maximum ratings Frequency ........................................ 120 MHz Anode voltage ......................................12 kV Anode current .................... . ..................6 A .......6 Anode dissipation .................. . kW Control-grid dissipation .......................... 70 W Screen-grid dissipation ........................270 W ( 1 ) Thomson Tubes E'ertroniques defines the operahng voltage according Io each particuiar situation As an indication for equipmeiit design purposes only a heater voitage of 9 V produces a heating current of 120 A (2) Values for coo1ii.g given for maxfmum a n o d e dissipaOon Example 1 Example 2 300 18 300 16 kHz dB 9 9 kV 600 800 V - 140 - 140 V Anode current, with signal 1.6 3.4 A Screen-grid current 1O0 230 mA Control-grid current 5 20 mA - 0.2 dB bandwidth Gain Anode voltage Screen-grid voltage Control-grid bias voltage FM tetrode i Output power up to 60 kW in FM radio transmitters General characteristics l I I I I Cathode .................................................................. horated tungsten drect dc or single phase ac Heating (1) ............................................... lnterelectrode capacitances, approx.: cathode-contrai grid ............................................................. 1O pF control grid-screen grid ........................................................... pF screen grid-anode .................................................................. O pF Amplification factor, average .............................................................. 6 110 mA/V Transconductance (la = 5 A, Vg2 = 800 V) ........................ Operating position ........................................................................ Weight, approx ............................................................................. 26 kg Dimensions .......................................................................Se page 55 Maximum ratings Frequency ........................................ 120 MHz Anode c001ing (2)................................................................... forced air . 1 kV air flow, min. .................................................................... 25 m3/mn Anode voltage ...................................... 0 0 "C Anode current ...................................... 25 A outlet air temperature, max. ................................................. Anode dissipation ................................. 30 kW Electrode terminal and ceramic seal cooling Control-grid dissipation ........................300 W air type ..................................................................................forced temperature on the tube, max. ................................................ "C Screen-grid dissipation ........................600 W (1) Thomson Tubes Electroniques defines the operabng voltage accord~ngto each particular situation As an indication for equipmenf deslgn purposes only. a heater voltage of 10 V produces a heating current of 210 A (2) Values for cooiing given for maxlmum anode d~ssssipation I I I Grounded-grid operation TYpical operation at 108 MHz in the matched cavity TH 18346 output power 60 kW - 0.2d B bandwidth 300 kHz Gain 14 dB Anode voltage 1O kV 1O00 V Screen-grid current 380 rn A Control-grid current 370 mA Screen-grid voltage Control-grid bias voltage Anode current, with signal TH 18346 matched circuit assembly For FM radio transmitters I -Y -- Operating frequency .......................................... Dimensions ........................................................ x 580 x 483 mm ........................ 65 kg Weight, approx (without tube) ...................... . RF connections: input ...................................................................femae type 718" output ............................................. .............A standard 3 1/8" Cooling................................................................................... forced air 24 THOMSON TUBES ELECTRONIQUES UHF tetrode i Output power upto 1.1 k W peak-of-sync in common amplification 2.2 kW peak-of-sync in vision carrier amplification General characteristics Cathode .................................................................. thoriated tungsten Heating (1) ..............................................direct, dc or single phase ac lnterelectrode capacitances, approx.: cathode-control grid ............................................................. 40 pF control grid-screen grid .......................................................... 50 pF screen grid-anode ........................ . . . ............................. 8.2 pF Amplification factor, average ............................................................ 7 Transconductance (la = 1.5 A, Vg2 = 400 V) ........................ 40 m A N Operating position ....................................................................veflical Weight, approx .......................................................................... 2.3 kg s e page 55 Dimensions .................................................................... Anode cooling (2) ................................................................. f o r c e air air flow, min. ................................................................... 2.5 m3/mn air inlet pressure, max .......................................................... 3 mbar outlet air temperature, max. ............................................ 0 0 OC Electrode terminal and ceramic seal cooling type ............................................................................... forced air temperature on the tube, max. ........................................... 250 ' C Maximum ratings ....1000 MHz Frequency .................... ......,. ....5 kV Anode voltage ........................... . . . Anode current .......................................... 2 A Anode dissipation ................................4.5 kW Control-grid dissipation ............................5 W Çcreen-grid dissipation ..........................25 W ( 1 ) Thomson Tubes Electronrques defrnes the operating voltage according Io each particular situation As an ~ndicationfor equipment design purposes only. a heater voilage of 6 Vproduces a heating curretlt of 34 A (2) Values for coolrng g ~ v e nfor anode dissipabon of 2 5 kW Typical operation at 800 MHz in the matched cavity TH 18363 Common amplification Vision only Peak-of-sync output power 1.1 2.2 - 1 d~ bandwidth 1O 1O Intermodulation products - 54 Gain 15.5 15.5 dB 4 4 kV Screen-grid voltage 400 400 V Anode current, with signal 0.8 1.5 A Screen-grid current 5 8 mA Control-grid current negligible 2 mA 0.5 0.5 A Anode voltage Anode current at zero signal TH 18363 I matched circuit assembly For UHF-TV transmitters and translators (Bands IV and V) L i 11 i 1 kW MHz Operating frequency ....................................................470 to 860 MHz Dimensions ......................................................... 644 x 268 x 200 mm Weight, approx (without tube) ..................................................... 20 kg RF connections: m a type N input ......................................................................... output .................................................................A standard 718" Cooling ...................................................................................f o r c e air THOMSON TUBES ELECTRONIQUES dB 1 AM tetrode i Output power 1kW in SSB, up to 110 MHz General characteristics Cathode .................................................................................... oxide Heating (1) ........................................................................................ lnterelectrodes capacitances, approx.(ground/cathode conection): input ....................... ...... ..................................................75 pF reaction ........................ . ................................................. 0.06 pF output .................................................................................. 14.5 pF Amplification factor, average ................... .. . ....................4.5 Transconductance (la = 0.3 A, Vg2 = 225 V) ..........................25 mA/V Operating position ................................................................... vertical Weight, approx .......................................................................... 0.84 kg Connector .............................................................................TH 16054 s e page 55 Dimensions ................................................................. for c e air Anode cooling (2) air flow. min .................... . . ......................................... 1.5 m3/mn 2 mbar air inlet pressure, max .................................................... outlet air temperature ........................................................... 100 "C Electrode terminal and ceramic cooling: type ............................................................................... forced air temperature on the tube, max .............................................. 2 OC . . I I Typical operation carrier conditions 26 Maximum ratings Anode voltage ........................................ 3 kV Control-grid voltage ............................ - 150 V Screen-grid voltage.. ............................,400 V Cathode current, average ...................... 0.9 A ............1.5 kW Anode dissipation ............. . . Control-grid dissipation ............................ 1W Screen-grid dissipation .......................... 12 W ( 1 ) Thomson Tubes Electroniques def~nesthe operating according each particuiar As an indication for equ~prnentdesign purposes only, a heater voltage of 6 Vproduces a heatlng current of 10.5 A. (2) Values for c o o l i n g g i v e n for maximum a n o d e dissipation. 1 kW 30 MHz Anode voltage 2.75 kV Screen-grid voltage 225 Control-grid bias voltage - 36 v v Anode current 700 mA Screen-grid current 20 mA Control-grid current 1 mA output power Freguency kt THOMSON TUBES ELECTRONIQUES FMNHF tetrode Output power 1 upto5.25kW peak-of-sync in common amplification 15 kW peak-of-sync in vision carrier amplification 1 General characteristics Cathode .................................................................thoriated tungsten Heating (1) ......................................................................................... lnterelectrode capacitances, approx.: cathode-control grid ........................................................... 83 pF control grid-screen grid .................................. ..................,135 pF screen grid-anode .................................................................. 17 pF Amplification factor, average ......................................................... 5.5 Transconductance (la = 1.5 A, Vg2 = 500 V) ........................ 60 mAlV Operating position .................................................................... vertical Weight, approx. ........................................................................... 7.5 kg Dimensions ....................................................................... s e page 55 Anode cooling (2)................................................................ forced air . ..........................................13 m3Imn air flow, min. ..................... corresponding pressure drop, max. .................................... 9 mbar OC outlet air temperature, max. ................................................O Electrode terminal and ceramic seal cooling f o r c e air type .................................................................................. . . ...............250 OC temperature on the tube, max. ..................... Maximum ratings Frequency ........................................ 300 MHz Anode voltage ......................................... 7 kV ........ 6 A Anode current ............................ . Anode dissipation ......................... 1 kW Control-grid dissipation ..........................50 W Screen-grid dissipation ........................150 W ( 1 ) Thomson T u i ~ e sElectron~quesdehnes the operatfng voltage according to each parficuiar s~tuatior? As an indication for equfpment desfgn purposes only, a heater voltage of 7 V produces a heatir~gcurrent of 140 A (2) Values /or cooiing given for maximum anode dissipahon. Typical operation at 224 MHz in the matched cavity TH 18326A Common amplification Vision only Peak-of-sync output power - 1 ,-JB bandwidth 5.25 9 15 9 Intermodulation products - 54 Gain 16.5 16 dB Anode voltage 5.4 5.6 kV Screen-grid voltage 600 600 V Anode current, with signal 2.4 3.2 A Screen-grid current 20 35 mA Control-grid current negligible negligible 1.8 1.2 Anode current at zero signal TH 18326A matched circuit assembly 1 kW M H ~ dB A - -a l For VHF-TV transmitters and translators (Band III) Operating frequency .................................................. 160 to 230 MHz Dimensions ........................................................1361 x 391 x 256 mm Weight, approx (without tube) ......................................................70 kg RF connections: input ....................................................................... femae, type N output .............................................................A standard 1 518" Cooling ................................................................................. forced air THOMSON TUBES ELECTRONIQUES 1 -u- --' ' { i P S I Y' 27 VHF tetrode i Output power up to 21 kW peak-of sync in common amplification 33 kW peak-of sync in vision carrier amplification General characteristics Cathode ................................................................ thoriated tungsten Heating (1) ..................... direct lnterelectrode capacitances, approx.: ..............130 pF cathode-control grid .......................................... . . ...................... 21 O pF control grid-screen grid ..................... . screen grid-anode ................................................................ 25 pF Amplification factor, average ........................................................... 8 Transconductance (la = 1.5 A, Vg2 = 600V) .........................140 mA/V . . . ...... .... d i c a l Operating position ......................... .Weight, approx. ............................................................................ 14 kg s e page 55 Dimensions ................................................................... forced air Anode cooling (2) 2 2 m3/mn air flow, min. .................................................... corresponding pressure drop ................... ...... ............12 mbar outlet air temperature, max. ............................ .............1 0 OC Electrode terminal and ceramic seal cooling o r air type ................................................................................... temperature on the tube, max. ...........................................250 OC . . Maximum ratings Frequency ...................................... 300 MHz Anode voltage ........................................ 8 kV Anode current .................................... 10 A Anode dissipation ............................... 8 kW Control-grid dissipation ........................150 W Screen-grid dissipation ........................400 W (7) Thomson Tubes Electroniques defines the operating voltage according to each particular situation. As an ~ndicationfor equiprnent deslgn purposes only, a heater voltage of 8 Vproduces a heating current of 180 A. (2) Values for cooling given for maximum anode d~ssipation. T ~ ~ i coperation al at 174 MHz in the matched cavity TH 18327A Common amplification Vision only Peak-of-sync output power 21 33 kW - 1 dB bandwidth 9 9 MHz Intermodulation products - 54 Gain 16.5 16.5 dB 6 5.9 kV Screen-grid voltage 600 600 V Anode current, with signal 5.4 6.3 A Screen-grid current 85 90 mA Control-grid current 15 25 mA Anode current at zero signal 2 2 A Anode voltage TH 18327A dB matched circuit assembly For VHF-TV transmitters and translators (Band III) Operating freq~iency....................................................170 to 230 MHz ........................... 977 x 450 x 344 mm Dimensions ....................... . . . . . ......................80 kg Weight, approx (without tube) .................... RF connections: female, type N input ................................. ........................................ output ............................................................... standard EIA 3 118" Cooling.................................................................................. forced air 28 THOMSON TUBES ELECTRONIQUES FM tetrode i Output power up to 12 kW in FM radio transmitters General characteristics Cathode .................................................................. h o r i a e d tungsten Heating (1) ................................................................direct, dc or ac lnterelectrode capacitances, approx.: cathode-control grid ............................................................... 78 pF control grid-screen grid ....................................................... 115 pF screen grid-anode .................................................................. 22 p i Amplification factor, average .............................................................. 8 Transconductance (la = 2.5 A, Vg2 = 800 V) ........................ 55 m A N Operating position ....................................................................vertical Weight, approx. ........................................................................... 6.7 kg Dimensions .......................................................................... page 55 Anode cooling (2)................................................................... forced air .................................................................... air fiow, 2 m3/mn corresponding pressure drap .............................................. 9 mbar 100 ' C outlet air temperature, max. ................................................. Electrode terminal and ceramic seal ~ 0 0 l i n g type ................................................................................. forced air temperature on the tube, max. .............................................220 ' C TYpical operation at 110 MHz for FM radio transmitters Grounded-cathode Operation Maximum ratings Frequency ........................................ 120 MHz Anode voltage ......................................... 9 kV Anode current ..........................................6 A Anode dissipation .................................1 kW Control-grid dissipation ........................100 W Screen-grid dissipation ........................300 W ( 1 ) Tlio~iisonTubes Electroniques defines the operatrng voltage accordirig to each partrcular situation. As an indication for equipment design purposes only, a heater voltage of 9.5 V produces a heaf~ngcurrent of 80 A. ( 2 ) Values for cooling g i v e n for m a x i m u m a n o d e dissipalion. Example 1 Example 2 15 1O kW 300 300 Gain 23 25 kHz dB Anode voltage 7.5 7.5 kV Screen-grid voltage 800 1O00 - 110 - 120 v v Anode current, with signal 2.3 2.35 A Screen-grid current 200 50 150 O mA mA output power - 0 2 dB bandwidth Control-grid bias voltage Control-grid current VHF tetrode i Output power q. up to 5.5 kW peak-of-sync in common amplification "*-- ' * -- tif* fd&&*.A#f&r*&&bt .'i 0 O n«nrcum wers L ml L a?s E ~ ~ $4.--' ~ ~ E S 15 kW peak-of-sync in vision carrier amplification General characteristics Cathode ............................................................... thoriated tungsten Heating (1) ....................................................................direct, dc or ac lnterelectrode capacitances, approx.: cathode-control grid ...............................................................76 pF control grid-screen grid ................................................... 122 pF . . .................................22 pF screen grid-anode .......................... Amplification factor, average ......................................................... 8.4 Transconductance (la = 3 A, Vg2 = 800 V) .............................70 mA/V Operating position ................................................ A i c a l Weight, approx. ......................................................................... 6 7 kg s e page 55 Dimensions ........................................................ forced air Anode cooling ( 2 )............................................................... air flow, min. .................................................................. 12 m3/mn corresponding pressure drop ........................................... 9 mbar outlet air temperature, max. ............................................... O OC Electrode terminal and ceramic seal cooling type .................................................................................. forced air temperature on the tube, max. ........................................... 250 OC T ~ ~ i cOperation al at 220 MHz for VHF-TV transmitters and translators (Band III) 30 Peak-of-çync output power - 1 dB bandwidth Maximum ratings Frequency ....................................... 250 MHz Anode voltage .................................... 5.5 kV Anode current ............................. 8A Anode dissipation ................................. 2 kW Control-grid dissipation ........................100 W Screen-grid dissipation ........................ 250 W ............ (1) Thomson Tubes Electroniques def~nesthe operatrng voltage according to each partrcular situation As an ind~cabonfor equrpment design purposes only a heater voltage of 10 V produces a heating current of 86 A (2) Values for cooling grven for maximum anode dissipation Common amplification Vision only 5.5 16 kW 9 7 MHz Intermodulation products - 54 Gain 15.5 14 dB Anode voltage 4.7 5.2 kV Screen-grid voltage 800 900 V Control-grid bias voltage - 70 - 90 V Anode current, with signal 2.4 3.8 A Screen-grid current 120 60 mA Control-grid current 20 50 mA dB THOMSON TUBES ELECTRONIQUES AM tetrode i Output power 5 kW SSB, up to 110 MHz General characteristics Cathode ................................................................... t h o r a t e tungsten Heating (1) ................................................direct, dc or single phase lnterelectrodes capacitances, approx. (grounded cathode): input ..................................................................................... 115 pF ..............................................................................O 4 pF reaction output ..................................................................................... 2 pF Maximum ratings Amplification factor, average ............................................................ ..7 Anode voltage ...................................... 6.5 kV Transconductance (la = 1.5 A, Vg2 = 600 V) .........................40 m A N Control-grid voltage ............................ - 200 V Operating position .....................................................................vertical'> 1-, Screen-grid voltage ............................... 9 0V Weight, approx ........................................................................... -. L Peak cathode current ..............................1O A Dimensions ...................................................................S page 55 Anode dissipation ...................................5 kW Control-grid dissipation .......................... 40 W Connecter 16121 Screen-grid dissipation .......................... 60 W Anode cooling (2) ~...~.....~.......................................................forced air air flow. min ........................................................................5 m3/mn corresponding pressure drop ...............................................9 mbar ( 1 ) Thomson Tubes Electroniques defines the operating voltage according to each particuiar s~tuation.As an outlet air temperature ........................................................... 100 O C ind~cationfor equipment design purposes only, a heater Electrode terminai and ceramic cooling: voltage of 6 V produces a heating current of 50 A. type ........................................................................................ air (2) Values for cooling g i v e n for maximum a n o d e dissipabon. temperature on the tube, max .............................................. 250 "C TYpical operation carrier conditions output power 5 kW Frequency 30 MHz Anode voltage 6 kV Screen-grid voltage 800 Control-grid bias voltage - 110 v v Anode current 1.5 A Screen-grid current 40 mA Control-grid current O A 0.7 A Anode current at zero signal UHF tetrode TH 382 Output power 0 1 peak-of-sync in common'amplification 11 kW peak-of-sync in vision carrier amplification General characteristics Cathode ................................................................... thoriated tungsten Heating (1) lnterelectrodes capacitaiices. approx.: ..............................72 p i cathode-control grid ....................... . . .....................93 pF control grid-screen grid .......................... . . screen grid-anode ...............................................................13.2 pF Amplification factor, average ............................................................ 8 Transconductance (la = 1.5 A, Vg2 = 300 V) ........................ 80 mA/V Operating position .....................................................................vertical Weight, approx ............................................................................... 7 kg Dimensions ....................................................................... s e page 55 Anode cooling (2).............................................................. forced air air flow, min ....................................................................13 m3imn corresponding pressure drop ........................................... 8 mbar outlet air temperature, ,pax. ................................................. 100 OC Electrode terminal and ceramic seal cooling type ................................................................................ forced air 300 O C temperature on the tube, rnax .............................................. .. Maximum ratings Frequency ......................................1000 MHz Anode voltage ...................................... 6.5 kV Anode current ......................... ........... . A Anode dissipation ........................ 2 5 kW Control-grid dissipation ..........................50 W Screen-grid dissipation ........................120 W (1) Thomson Tubes Electroniques defines the operating voltage according to each parlicular situation As an indication for equipment design purposes oniy a heafer voltage of 4 2 V produces a heating current of 125 A (2) Values for cooling given for maximum anode dissipation T ~ ~ i c Operation al at 800 MHz in the matched cavity TH 18482 Peak-of-sync output power - 1 dB bandwidth , I TH 18482 Common amplification Vision onlv 5.25 11 kW 12 12 MHz Intermodulation products - 52 Gain 15.5 15.4 dB Anode voltage 5.5 5.5 kV Screen-grid voltage 600 600 V Anode current, with signal 2.7 3.25 A Screen-grid current 30 30 mA Control-grid current 1O 5 mA Anode current at zero signal 1.2 1.2 A dB matched circuit assembly For UHF-TV transmitters and translators (Bands IV and V) Operating frequency .................................................... 470 to 860 MHz Dimensions ,..,.....,,.,,,..................................... 1 143 x 391 x 256 mm Weight, approx (without tube) ......................................................70 kg RF connections: input ...................................................................... femae, type N output ................. ................. . . . . . . . . . . . .standard EIA 1 518" or 3 118" Cooling ................ . . ............................................................ forced air 32 THOMSON TUBES ELECTRONIQUES UHF tetrode rn Output power '------ up to 2.2 kW peak-of-sync in common amplification 4.4 kW peak-of-sync in vision carrier amplification 2.5 kW in sound carrier amplification ) i i General characteristics Cathode ................................................................... t h o r a e tungsten direct Heating (1) ................................................................................... lnterelectrodes capacitances, approx.: ............................45 pF cathode-control grid ........................... control grid-screen grid ........................................................ 72 pF screen grid-anode ................................................................ 9 PF Amplification factor, average ......................................................... 8 Transconductance (la = 1.5 A, Vg2 = 400 V) .........................80 mA/V Operating position ................................................................... vertical Weight, approx ..........................................................................3.6 kg Dimensions .......................................................................s e page 55 Anode cooling (2)..................................................................f o r c e air air flow, min ...................................................................... 8 m3lmn corresponding pressure drop ................................... 9 mbar outlet air temperature, max. .......................................... 0 0 "C Electrode terminal and ceramic seal cooling type .................................................................................f O air temperature on the tube, max .................... . ..........y ..........300 "C . . . -yF? ...,J .- Maximum ratings Frequency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ..looOMHz Anode voltage ......................................... 6 kV Anode ..................................... A Anode dissipation ......................... . 7 5 kW ControI-grid diçsipation .......................... 25 W Screen-grid dissipation .......................... 75 W (1) Thomson Tubes Electroniques defines the operatrng voltage according to each particular situation. As an indication for equrpment design purposes only, a heater voltage of 6 Vproduces a heating current of 65 A. (2) Values for coolrng glven for maximum anode dissipation. Common Sound amplification only Typical operation at 800 MHz in the matched cavity TH 18665 TH 18665 Vision only 2.5 11 5 11.5 kW kW MHz 16 16 16 dB dB Anode voltage Screen-grid voltage Anode current, with signal Screen-grid current Control-grid current 5.5 600 1.6 1O negligible 4 500 2 30 5 5 700 1.9 15 1 - Anode current at zero signal 0.9 0.85 0.9 11.5 Intermodulation products - 52 Gain matched circuit assembly For UHF-TV transmitters and translators (Bands IV and V) . ...................470 to 860 MHz Operating frequency ....................... Dimensions .......................................................... 788 x 335 x 220 mm .............45 kg Weight, approx (without tube) ............................... RF connections: input ............................................................................male, type N output ...............................................................standard EIA 1 518" Cooling ................................................................................ f o r c e air ......... 4.4 2.2 ~eak-of-sync output power Sound carrier output power -1 dB bandwidth r 1 .&- kV V A mA mA A I 1 AM tetrode i Output power 12 kW in SSB, up to 120 MHz General characteristics Cathode ..................... . . .................................. h o a e tungsten Heating (1) ........................................... direct, dc or single phase lnterelectrodes capacitances, approx. (grounded cathode): input ................................................................................... 218 pF reaction ..................... . ......................................................0.8 pF output .................................................................................. 17 pF Amplification factor, average ......................................................... 5.5 Transconductance (la = 2 A) ........................ . ...................O mA/V Operating position .................................. . . . ........................veriical . . .............................. 7.5 kg Weight, approx ..................................... Dimensions s e page 55 Connector ......................................................................... TH 161 16 ................................... Anode cooling (2) .................... . . . forced air air flow, min ...................................................................... 13 m3imn corresponding pressure drop .................................... . .......8 mbar . . . . . . . . . . .100 "C outlet air temperature .................................. Electrode terminal and ceramic cooling: type ........................................................................... foced air temperature on the tube, max ........................................... 250 OC T ~ ~ i coperation al carrier conditions Maximum ratings Anode voltage ................................. 8 kV Control-grid voltage ............................ - 200 V Screen-grid voltage .................. . ....... 800 V Peak cathode current .................. . .........40 A . . . . . .12 kW Anode dissipation ................... Control-grid dissipation ........................100 W Screen-grid dissipation ........................ 250 W Anode current at zero signal ..................1.2 A (1) Thomson Tubes Electron~quesdefines the operating voltage according Io each particular situation As an indication for equlpment design purposes only a heater voltage of 7 V produces a heat~ngcurrent of 140 A (2) Values for c o o l ~ n ggiven for maximum anode diss~pation output power 1O k~ F;equency 30 MHz Anode voltage 7.2 kV Screen-grid voltage 600 V - 100 V Anode current 2.4 A Screen-grid current 30 mA Control-grid current O mA 1.2 A Control-grid bias voltage Anode current at zero signal 34 THOMSON TUBES ELECTRONIQUES AM tetrode rn Output power 50 kW in SW and MW, up to 30 MHz i -* " >& u General characteristics Cathode ...................................................................thoriated tungsten Heating (1) ...................................................................................dire~t Interelectrodes capacitances, approx.: cathode-control grid .............................................................140 pF control grid-screen grid .......................... . .......................265 pF control grid-anode .................................................................1.4 pF screen grid-anode .................................................................. 35 pF Amplification factor, average ...........................................................4.8 Transconductance (la = 4 A, Vg2 = 800 V) ............................80 mA/V Operating position .....................................................................vertical Weight, approx .............................................................................13 kg page 55 Dimensions .......................................................................see Connector ............................................................................... 16101 Anode cooling (2) .................................................................. Vapotron Electrode terminal cooling ..................................................... forced air 650 llmn air flow, min. ..................................................................... air inlet pressure, max .....................................................12 mbar Temperature on the tube, max .................................................. 150 OC TYpical operation Class C - Carrier conditions Maximum ratings Anode voltage ....................................... 13 kV Control-grid voltage ............................- 500 V Screen-grid voltage .................................1 kV Peak cathode current ..............................60 A Anode dissipation ............................... 60 kW Control-grid dissipation ...................... 300 W Screen-grid dissipation .......................,600 W ( 1 ) Thomson Tubes Electronrques defines the operatmg v o l t a ~ eaccordinq to each particular situation As an jndicitlon for equ'bmeflf design PurPoses OfllY, a heater voltage of 10 V produces a heating current of 200 A. ( 2 ) Values for cooling g i v e n for m a x i m u m a n o d e d~ssipahon. o u t p u t power 55 kW Frequency 30 MHz Anode voltage 11 kV 700 V - 300 V Anode current 7.5 A Screen-grid current 150 mA Control-grid current 400 mA Screen-grid voltage Control-grid bias voltage THOMSON TUBES ELECTRONIQUES 35 UHF tetrode i Output power - up to 550 W peak-of-sync in common amplification 1 kW peak-of-sync in vision carrier amplification 1.2 k W in sound carrier amplification General characteristics Cathode ................................................................... h o r i a e tungsten Heating (1) ...................................................................................direCt lnterelectrodes capacitances, approx.: cathode-control grid 40 pF control grid-screen grid .......................................................... pF screen grid-anode ................................................................. 8.2 pF Amplification factor, average .......................................................... 7 Transconductance (la = 1.5 A, Vg2 = 400 V) .........................40 mA/V Operating position .................................................... veflical, anode UP Weight, approx ............................................................................ 2.1 kg . Dimensions .......................................................................see page 55 Anode cooling (2) ....................................................... Hypervaporo Maximum ratings water flow, min ..................... . . . ................................. 3 I/mn Frequency .................................. 0 0 0 MHz water inlet pressure, max ........................................................ 5 bar Anode voltage .........................................5 kV outlet water temperature, less than ...................................... 80 OC Anode current .................... . ..................2 A Electrode terminal and ceramic seal cooling Anode dissipation ...................................5 kW type .................................................................................. forced air Control-grid dissipation ............................ 5W .............................................. temperature on the tube, man 250 OC Screen-grid dissipation ..........................25 W (1) Thomson Tubes Electroniques defines the operating voltage according to each particular situation. As an ~ndicationfor equipment design purposes only, a heater voltage of 5.8 V produces a heating current of 34 A. (2) Values for cooling given for maximum anode dissipation. Sound only amplification T y ~ i c aoperation l at 850 MHz in the matched cavity ' TH 8563 carrier output power 1.2 kW - 1 dB bandwidth 10 MHz 15.5 d~ 4 kV Gain Anode voltage Screen-grid voltage Anode current, with signal Screen-grid current Control-gridcurrent Anode current at zero signal TH 18563 A 0.5 matched circuit assembly For UHF-TV transmitters and translators (Bands IV and V) . . negligible "*pg i :% 2 Operating frequency .................................................. 470 to 860 MHz 670 x 268 x 174 mm Dimensions .......................................................... Weight, approx (without tube) ...................................................... 17 kg RF connections: input ....................................................................... f e m a e type N output ............................................................ standard EIA 718" Cooling .............................................. Hypervapotron and forced air 36 THOMSON TUBES ELECTRONIQUES AM tetrode TH 532 Output power 60 kW in SW and MW, up to 30 MHz General characteristics Cathode ................................................................... t h o r a t e tungsten Heating (1) ....................................................direct, dc or single phase lnterelectrodes capacitances, approx.: cathode-control grid ............................................................. 140 pF control grid-screen grid .....................................................265 pF control grid-anode .................... . ......................................... 1.4 pF screen grid-anode ................................................................35 pF Amplification factor, average ......................................................... 4.8 80 mA/V Transconductance (la = 4 A) ................................................ Operating position .............................................v e c a anode up Weight, approx ............................................................................. 17 kg Dimensions ...................................................................... s e page 55 Connector ........................................................................... T H 16118 Anode cooling (2) ......................................................... Hypervapotron water flow, min ......................................................................... 25 I/mn water inlet pressure, max ........................................................ 5 bar outlet water temperature, less than ..................................... 80 O C Electrode terminal and ceramic cooling: type ................................................................................. f o r c e air temperature on the tube, max ..............................................200 "C T ~ ~ i coperation al carrier conditions Maximum ratings Anode voltage ....................................... 12 k V Control-grid voltage .................... -.... 500 V Screen-grid voltage ............................. 900 V Peak cathode current ............................ 70 A Anode dissipation ............................... 6 kW Control-grid dissipation ........................300 W Screen-grid dissipation .......................,600 W ( 1 ) Thomson Tubes Electroniques defines the operating voltage according to each particular situation As an ind~cationfor equipment design purposes only a heater voltage of 10 V produces a heating current of 200 A (2) Values for cooling g l v e n for m a x i m u m a n o d e d~ssipaoon output power 55 k~ Frequency 30 MHz - 300 V Anode current 7.5 A Screen-grid current 150 mA Control-grid current 350 A Anode voltage Screen-grid voltage Control-grid bias voltage 1 J1 t> THOMSON TUBES ELECTRONIQUES B TH 532 AM tetrode Output power 60 kW in SW and MW, up to 30 MHz General characteristics Cathode ......................................................................... tungsten Heatinq - .(1) . ...................................................direct dc or single phase lnterelectrodes capacitances, approx.: cathode-control grid .......................................................pF control grid-screen grid ................................................... ...265 PF control grid-anode ............................................................... 1.4 pF screen grid-anode ..-..., .. ............................................ 35 pF Maximum ratings Anode voltage ....................................... 12 kV Amplification factor, average ......................................... 4 8 Control-grid voltage ............................ 500 V Transconductance (la = 4 A) .............................................O mNV ...............................900 V Operating position ...................................................vertica 1. anode up Screen-grid voltage Peak cathode current ..............................70 A Weight, approx ..........................................................................1 kg Anode dissipation ............................... 60 kW Dimensions ........................................................................ page 55 dissipation ........................300 W Connecter ...........................................................................161 18 Control-grid Screen-grid dissipation ........................600 W Anode cooling (2) .........................................................Hypewapotron water flow, min ..........................................................................25 Ilmn 5 bar ( 7 ) Thomson Tubes Electroniques defines the operahng water iniet pressure, max ........................................................ voltage accord~ngto each particular situation As an outlet water temperature, less than ....................................... 8 "C indication for equipment design purposes only, a heater Electrode terminal and ceramic ~00ling: voltage of 10 V produces a heating current of 200 A (2) Values for c o o l i n g g i v e n for m a x i m u m a n o d e type . ............................................................................... forced air diss~pation temperature on the tube, max .............................................. 200 OC - Typical operation carrier conditions o u t p u t power 55 kW Frequency 30 MHz Anbde voltage 11 kV 700 - 300 v v Anode current 7.5 A Screen-grid current 150 Control-grid current 350 mA A Screen-grid voltage Control-grid bias voltage AM tetrode Output power 350 kW in LW and MW, 300 kW in SW,up to 50 MHz General characteristics Cathode ................................................................... horated tungsten Heating (1) .............................................. direct, dc or single phase lnterelectrodes capacitances, approx.: cathode-control grid .......................................................... O pF control grid-screen grid ................................................... 510 pF control grid-anode ...................................................... . . .....4.5 pF screen grid-anode ................................................................ 74 pF ............................. 4.3 Amplification factor, average .................... . . . Transconductance (la = 25 A, Vg2 = 1000 V) ......................400 mNV Operating position ...................................... , l ac . . anode up Weight, approx ........................................................................... 56 kg Dimensions ................................................................... s e page 55 Connector ............... . ..................................................... TH 16108A Anode cooling (2) ..................................................... Hypewapotron water flow, min ............................................................... 150 I/mn water inlet pressure, max .................................................... 5 bar 80 "C outlet water temperature, less than .................................. Electrode terminal and ceramic cooling: type .................................................................................. forced air 200 OC temperature on the tube, max .......................................... T y ~ i c aoperation l carrier conditions Maximum ratings Anode voltage ....................................... 15 kV Control-grid voltage ............................- 800 V Screen-grid voltage .......................... 1200 V Peak cathode current ............................400 A Anode dissipation ............................. 300 kW Control-grid dissipation ..........................2 kW Screen-grid dissipation ..........................5 kW (1) Thomson Tubes Electroniques defines the operating voltage according to each parlicular situation. As an indication for equipmenl design purposes only. a healer voltage of 18 V produces a heating current of 430 A. (2) Values for cooling given for maximum anode dissipation. output power 300 kW Frequency 30 MHz Anode voltage 14 kV 1O00 V 1 A Screen-grid voltage Control-grid bias voltage Anode current Screen-grid current Control-grid current 38 ,,\ M O M S O N TUBES ELECTRONIQUES AM tetrode Output power 1.25 MW in LW and MW General characteristics Cathode ................................................................. thoriated tungsten Heating (1) ...................................................direct, dc or single phase lnterelectrodes capacitances, approx.: cathode-control grid .............................................................830 pF control grid-screen grid .................................................... 1600 pF . ............................ 15.5 pF control grid-anode ............................... screen grid-anode ................................................................220 pF Amplification factor, average .................... . ......................................5 Transconductance (la = 35 A, Vg2 = 1000 V) ..................... ,600 m A N Operating position ..............................................v e i c a anode up Weight, approx ........................................................................... 155 kg Dimensions ...................................................................... s e page 55 Connector .............................................................................. 16114 Anode cooling (2) ......................................................... Hypewapotron water flow, min .......................................................... 40O I/mn water inlet pressiire, max .......................................................5 bar outlet water temperature, less than ..................................... 80 OC Electrode terminal and ceramic cooling: type .................................................................................. f o r c e air temperature on the tube, max ..............................................200 "C TYpical operation carrier conditions ( 1 ) Thomson Tubes Electroniques defines the operabng voilage according !O each parficular situation As an indication for equipmenf design purposes only a heater voltage of 30 V produces a heating current of 900 A (2) Values for cooling g i v e n for m a x i m u m a n o d e dissipation output power 1000 k~ 2 MHz Anode voltage 13.0 kV Screen-grid voltage 1100 V Control-grid bias voltage - 550 V 85 A Screen-grid current 8 A Control-grid current 7 A Frequency Anode current Lt THOMSON TUBES ELECTRONIQUES Maximum ratings Anode voltage ..................................... 15 kV Control-grid voltage ............................- 800 V Screen-grid voltage .............................1250 V Peak cathode current ........................ 1300 A Anode dissipation ............................... 1 MW Control-grid dissipation ..........................6 kW Screen-grid dissipation ........................16 kW 39 UHF tetrode i Output power up to 1.1 kW peak-of-sync in common amplification General characteristics Cathode ................................................................. t h o r i a e tungsten Heating (1) ......................................................................................... lnterelectrodes capacitances, approx.: cathode-control grid ............................................................... 40 pF control grid-screen grid ..........................................................5 PF screen grid-anode ................................................................. 8.2 pF Amplification factor, average ............................................................ 7 Transconductance (la = 1.5 A, Vg2 = 500 V) ..........................40 mA/V Operating position ................................................... v e i c a anode up Weight, approx ............................................................................ 2.1 kg Dimensions .....................................................................See page 55 . . . . ............................ Hypervapotron Anode cooling (2) ................... Maximum ratings water flow, min ...................................................................... 3 I/mn Frequency ...................................... 1000 MHz ............................... 5 bar Anode voltage ..................................... water iniet pressure, rnax ................ 5 kV ............. 80 OC Anode current ......................... outlet water temperature, less than ..................... . .............2 A . Electrode terminal and ceramic seal cooling ...........‘.....5 kW Anode dissipation .......... . ................................................. forced air Control-grid dissipation ............................5 W type ........................ Screen-grid dissipation ..........................25 W ternperature on the tube, rnax ............................ . . . . . . . . . .250 OC . . . . . . . (1) Thomson Tubes Electroniques defines the operating voltage according to each parîicular situation. As an indication for equipment design purposes only, a heater voltage of 6 V produces a heating current of 34 A (2) Values for cooling g~venfor maximum anode dissipalion. TYpical operation at 850 MHz in the matched cavity TH 18563 Common amplification Vision only Peak-of-çync output power 1.1 2.2 kW - 1 dB bandwidth 1O 1O MHz Intermodulation products - 54 Gain 15.5 15.5 dB 0.8 1.5 A Screen-grid current 5 8 mA Control-grid current negligible 2 mA 0.5 0.5 A dB Anode voltage Screen-grid voltage Anode current, with signal Anode current at zero signal TH 18563 matched circuit assembly For UHF-TV transmitters and translators (Bands IV and V) 470 to 860 MHz Operating frequency .................................................... Dimensions ........................................................ 670 x 268 x 174 mm Weight, approx (without tube) .................................................... 17 kg RF connections: input ........................................................................f e m a e type N output ................................................................ standard EIA 718" Cooling ................................................. Hypervapotron and forced air 40 ,,\ MOMSON TUBES ELECTRONIQUES Output power 250 kW in LW and MW, 200 kW in SW, up to 50 MHz General characteristics Cathode ................................................................... thoriated tungsten Heating (1)..................................................direct, dc or single phase lnterelectrodes capacitances, approx.: cathode-control grid ....................................................... 3 0 pF control grid-screen grid ........................................................440 pF control grid-anode ....................................................................4 pF screen grid-anode ........................................................6 2 PF Amplification factor, average ...................................................... 4.8 Transconductance (la = 15 A, Vg2 = 1000 V) ......................220 rWW Operating position .................................................. veflical, anode up Weight, approx .........................................................................38 kg Dimensions .................................................................... page 55 Connecter ........................................................... 161 10 Anode cooling (2) .........................................................Hypervapotron water flow, min ..................................................................110 Ilmn Maximum ratings Anode voltage ....................................... 15 kV - 800 V Control-grid voltage ............................ Screen-grid voltage ..............................1 2 kV Peak cathode current ............................300 A Anode dissipation ............................... 250 k~ Control-grid dissipation .......................1.5 kW Screen-grid .......................... kW water inlet pressure, max ........................................................5 bar outlet water tWnperat~re,less than .......................................8 OC Electrode terminal and ceramic ~00ling: ..................................................................................O air type temperature on the tube, max ..............................................200 OC Typical operation carrier conditions (,, Tho,son Electroniques defines the operahng voltage accord~ngto each parficular s~tuation.As an ~ndicationfor equipment design purposes only, a heater voltage of 15 Vproduces a heating current of 320 A. (2) Values for cooling given for maximum a n o d e dissipation. output power 200 kW Frequency 30 MHz Anode voltage 14 kV Screen-grid voltage 1O00 v Control-grid bias voltage - 550 v Anode current 17 A Screen-grid current 0.9 0.9 A Control-grid current A AM tetrode Output power 650 kW in LW and MW, 550 kW in SW, up to 50 MHz General characteristics Cathode ................................................................... thoriated tungsten direct, dc or single phase Heating (1) ................................................ lnterelectrodes capacitances, approx.: cathode-control grid ........................................................... 445 pF control grid-screen grid ...................................................... 750 pF control grid-anode ................................................................. 6.3 pF screen grid-anode .............................................................. 100 pF Amplification factor, average ................... .............................4.4 Transconductance (la = 35 A, Vg2 = 1000 V) ......................500 mA/V Operating position ................... ...... ................. v e i c a anode up Weight, approx ........................................................................... 74 kg s e page 55 Dimensions Connector ............................................................................ 16124 Anode cooling (2) ............................... . ......................Hypewapotron water flow, min 20 I/mn water inlet pressure, max ...................................................... 5 bar outlet water temperature, less than ...................................... 80 OC Electrode terminal and ceramic cooling: type ............................ . . . .............................................. forced air temperature on the tube, max ................... .............. . .O OC . . . . ....................................................................... ................................................................ . . TYpical operation carrier conditions Maximum ratings Anode voltage ..................................... 15 kV Control-grid voltage .......................... - 800 V Screen-grid voltage .......................... 1.25 kV Peak cathode current ............................ 600 A Anode dissipation ............... . . ........ O 0 kW Control-grid dissipation ..........................3 kW Screen-grid dissipation ..........................8 kW ( 1 ) Thomson Tubes Electroniques defines the operating voltage according to each particular situation, As an indication for equipment design purposes only, a heater voltage of 23 Vproduces a heating cuvent of 500 A. ( 2 ) Values for c o o l ~ n ggiven for maximum anode dissipation. output power 550 kW Frequency 30 MHz Anode voltage 14 kV Screen-grid voltage 1O00 V Control-grid bias voltage - 550 V Anode current 47 A Screen-grid current 4.2 A Control-grid current 4 A M O M S O N TUBES ELECTRONIQUES VHF tetrode i Output power up to 10.5 kW peak-of-sync in common amplification 15 kW peak-of-sync in vision carrier amplification General characteristics Cathode .................................................................. t h o r a t e tungsten Heating (1) ...................................................................................direct lnterelectrodes capacitances, approx.: cathode-control urid - ............................................................... 83 DF control grid-screen grid .................................................... 135 pF screen grid-anode .................................................................. 17 pF Amplification factor, average ......................................................... 5.5 Transconductance (la = 2 A, Vg2 = 500 V) .................... . .....60 m A N Operating position ......................................d i c a l , anode up Weight, approx ............................................................................ 4.4 kg Dimensions ......................................................................s e page 55 Hypervapotron Anode cooling (2) ...................................................... water flow, min ....................................................................12 I/mn water inlet pressure, max ...................................................5 bar outlet water temperature, less than ..................................... 80 O C Electrode terminal and ceramic seal cooling type ................................................................................ f o r c e air temperature on the tube, max ...........................................250 OC Maximum ratings Frequency ................................ 300 MHz Anode voltage .........................................7 kV Anode current ....................................... A Anode dissipation .............................20 kW Control-grid dissipation ..........................50 W Screen-grid dissipation ........................150 W (1) Thomson Tubes Electroniques defines the operating voltage according to each parficular situation. As an indication for equipment design purposes only, a heater voltage of 7 V produces a heabng current of 140 A (2) Values for cooling given for maximum anode dissipation. T~~ical at 174MHz in the matched cavity TH 18526 Peak-of-sync output power - 1 dB bandwidth Intermodulation products Vision only 10.5 15 kW 9 9 MHz - 50 dB Gain 16 16 dB Anode voltage 5.5 5.5 kV Screen-grid voltage 600 600 V Anode current, with signal 3.1 3.2 A Screen-grid current 30 35 mA Control-grid current 3 negligible mA 1.2 1.2 A Anode current at zero signal TH 18526A Common amplification matched circuit assembly For VHF-TV transmitters and translators (Band III) Operating frequency .................................................... 170 to 230 MHz Dimensions ........................................................1430 x 420 x 266 mm Weight, approx (without tube) .................................................... 70 kg RF connections: input ......................................................................... f e m a e type N output ............................................................... standard EIA 3 118" Cooling ....................................... nor topa. and forced air THOMSON TUBES ELECTRONIQUES 43 AM tetrode Output power 12 kW in SW, up to 300 MHz General characteristics Cathode ................................................................. thoated tungsten Heating (1) .................................................direct, dc or single phase lnterelectrodes capacitances, approx.: cathode-control grid ............................................................ 83 pF control grid-screen grid .................... ..................................3 5 pF control grid-anode ........................... . ..................................0.8 pF screen grid-anode .................................................................. 17 pF Amplification factor, average .............................. . . .....................5.5 Transconductance (la = 1.5 A, Vg2 = 500 V) .........................60 m A N Operating position ............................................................... vertical Weight, approx ............................................................................4.4 kg Dimensions .......................................................................s e page 55 Connector ........................................................................... TH 16132 Anode cooling (2) ......................................L a p o t r o n water flow, min .................................................................... 8 Ilrnn water inlet pressure, rnax ...................................................... 5 bar outlet water temperature, less than .......................................80 OC Electrode terminal and ceramic cooling: forced air type ........................................................................... temperature on the tube, max ......................................... .....250O C TyPical operation carrier conditions Maximum ratings Anode dc voltage ....................................8 kV Control-gnd voltage ............................- 200 V Screen-grid voltage ...............................800 V Peak cathode current .............................. 30 A Anode dissipation ..............................20 kW Control-grid dissipation ........................100 W Screen-grid dissipation ........................250 W (7) Thomson Tubes Electroniques def~nesthe operating voltage according to each particular situation. As an indicar~onfor equlpment design purposes only, a heater voltage of 7 Vproduces a heating current of 140 A. (2) Values for cooling given for maximum anode dissipation. output power 12 k~ Frequency 30 MHz Anode voltage 7.5 kV Screen-grid voltage 600 V - 145 V Anode current 2.3 A Screen-grid current 1O 0 mA Control-grid current 1O mA Control-grid bias voltage THOMSON TUBES ELECTRONIQUES AM tetrode i Output power 12 kW up to 120 MHz General characteristics Cathode ................................................................... t h o r i a e tungsten dc or single phase Heating (1) ..............................................direct lnterelectrodes capacitances, approx.: cathode-control grid ............................................................72 pF control qrid-screen grid ........................................................ 92 pF control grid-anode ............................................................... ..0.8 pF screen grid-anode .................................................................. 6 pF Amplification factor, average .......................................................... .5.5 60 m N V Transconductance (la = 2 A, Vg2 = 500 V) ............................ Operating position ...................................................v e i c a anode up Weight, approx ................................................ .................4.4 kg Dimensions .......................................................................... page 55 Anode cooling (2) ......................................................... Hypewapotron water flow, min ...................................................................... 8 I/mn water inlet pressure, max ............................... . . . . . . . . . . . . . . . 5. bar ..............80 ' C outlet water temperature, less than ..................... . Electrode terminal and ceramic cooling: type .................................................................................. forced air temperature on the tube, max ............................................ 250 OC Typical operation carrier conditions Maximum ratings Anode voltage ....................................8 kV Control-grid voltage ................... -..... 200 V Screen-grid voltage ............................... 800 V Peak cathode current .............................. 40 A Anode dissipation .......... . . ............20 kW Control-grid dissipation ........................100 W Screen-grid dissipation ...................... 250 W ( 1 ) Thomson Tubes Electroniques dehnes the operahng voitage accord~ngto eacli particuiar situation As an indication for equipment design purposes only a heater voilage of 7 V praduces a heating current of 140 A ( 2 ) Values for cooiing grven for maxrrnurn anode dissipation output power 12 kW Frequency 30 MHz Anode voltage 7.5 kV Screen-grid voltage 500 V Control-grid bias voltage - 110 V Anode current 2.3 A Screen-grid current 1O0 mA Control-grid current 10 mA UHF tetrode i Output power up to 31.5 kW peak-of-sync in common amplification 44 kW peak-of-sync in vision carrier amplification General characteristics Cathode ................................................................... t h r a e d tungsten Heatina (1) ......................................................................................... . lnterelectrodes capacitances, approx.: cathode-control grid ............................................................... 92 pF control grid-screen grid ........................................................ 148 pF screen grid-anode .................................................................. 18 pF Amplification factor, average .......................................................... .5.5 Transconductance (la = 4 A, Vg2 = 600 V) .......................... 100 m N V Operating position ....................................................verticalanode up Weight, approx .......................................................................... ..6.5 kg Dimensions ......................................................................... page 55 Anode c001ing (2).......................................................... Hypervapotron water flow, min .................................................................... 50 limn 5 bar water inlet pressure, max ........................................................ 80 OC outlet water temperature, less than ....................................... Screen grid terminal cooling ........................................................ water water flow, min ...................................................................... 2 I/mn Eiectrode terminal and ceramic seal cooling type .................................................................................. forced air temperature on the tube, max ............................................ 300 OC .,\ f Maximum ratings Frequency ......................................1000 MHz Anode voltage .........................................9 kV Anode current ...........................................9 A Anode dissipation ................................. 42 kW Control-grid dissipation ..........................80 W Screen-grid dissipation ........................200 W (1) Thomson Tubes Electroniques defines the operating voltage accord~ngto each particular situation As an ~ndicationfor equiprnent design purposes only, a heater voltage of 5 2 Vproduces a heating current of 210 A (2) Values for cooling given for maximum anode dissipation T Y P ~ operation c~~ at 700 MHz in the matched cavity TH 18550 TH 18550 Common amplification Vision only Peak-of-sync output power - 1 dB bandwidth 31.5 12 44 kW 12 MHz Intermodulation products - 48 Gain 14.5 14.7 dB Anode voltage 8.5 9 kV Screen-grid voltage 800 800 V Control-grid bias voltage - 113 - 114 v Anode current, with slgnal 6.45 Screen-grid current 130 6.75 70 mA Control-grid current 150 90 mA d6 A matched circuit assembly For UHF-TV transmitters and translators (Bands IV and V) 460 to 860 MHz Operating frequency 1 8 3 Dimensions ........................................................ x 349 x 353 mm Weight, approx (without tube) ......................................................70 kg RF connections: f e m a e type LC or 7116 input ........................................................... output ............................................................... standard EIA 3 118" Cooling ................................................... Hypewapotron and forced air 46 1,\ THOMSON TUBES ELECTRONIQUES I I I I VHF tetrode i Output power up to 21 kW peak-of-sync in common amplification 41 kW peak-of-sync in vision carrier amplification General characteristics Cathode ............................................................... thoriate tungsten direct, dc or single phase Heating (1) .............................................. lnterelectrodes capacitances, approx.: cathode-control grid ............................................................. 130 pF control grid-screen grid ..................................................... 21 O pF screen grid-anode .................................................................. 25 pF Amplification factor, average ............................................................ 8 Transconductance (la = 5 A, Vg2 = 600 V) ...........................140 m A N Operating position ...................................................v e i c a anode up Weight, approx .......................................................................... 7.5 kg Dimensions ....................................................................... s e page 55 Anode cooling (2) ..........................,..............................Hypervapotron water flow, min ....................................................................8 Ilmn water inlet pressure, max ........................... . . .....................5 bar outlet water temperature, less than ............................... . ....80 "C Electrode terminal and ceramic seal cooling type ................................................................................ f o r c e air 250 OC temperature on the tube, max .............................................. Maximum ratings Frequency ............. . ...................... 300 MHz Anode voltage ........................................ 8 kV Anode current ......................................... 1O A Anode dissipation ............................... 50 kW Control-grid dissipation ........................150 W Screen-grid dissipation ........................400 W (1) Thomson Tubes Electroniques dehnes the operating voltage according to each parlicular situation As an indicallon for equipment design purposes only, a heater voltage of 8 V produces a heahng current of 185 A (2) Values for cool~nggiven for maximum anode dissipation T ~ ~ i coperation al at 174 MHz in the matched cavity TH 18527A Peak-of-sync output power - 1 dB bandwidth Vision only 21 41 kW 9 8.5 MHz Intermodulation products - 54 Gain 16.5 17 dB 6 7.3 kV Screen-grid voltage 600 600 V Anode current, with signal 5.4 5.9 A Screen-grid current 85 120 mA Control-grid current 15 10 mA Anode current at zero signal 2 2 A Anode voltage TH 18527A Common amplification dB matched circuit assembly For VHF-TV transmitters and translators (Band III) I 1 Operating frequency ....................................................170 to 230 MHz Dimensions ........................................................1053 x 479 x 330 mm Weight, approx (without tube) .....................................................90 kg RF connections: femae, type N input ..................................................................... output ............................................................... standard EIA 3 118" Cooling ................................................... Hypeapotron and forced air THOMSON TUBES ELECTRONIQUES 1 1 47 I 1 AM tetrode i Output -- power 350 kW in LW and MW, 300 kW in SW, up to 50 MHz General characteristics Cathode ................................................................... h o r a t e d tungsten d r e c dc or single phase Heating ( 1 ) .................................................... lnterelectrodes capacitances, approx.: cathode-control grid ............................................................. 5 pF control grid-screen grid ........................................................ 610 pF control grid-anode ................................................................. 4.7 pF ,........85 pF screen grid-anode ......................................................... Amplification factor, average ........................................................... 4.3 Transconductance (la = 25 A, Vg2 = 1000 V) ......................400 mAlV Operating position ....................................................vertical, anode up Weight, approx ............................................................................. 60 kg page 55 Dimensions .......................................................................see Connecter ............................................................................... 16124 Anode cooling (2) ......................................................... Hypervapotron water flow, min ................................................................. 150 Ilmn 5 bar water inlet pressure, max ........................................................ outlet water temperature, less than .......................................8 OC Electrode terminal and ceramic cooling: type .................................................................................. forced air temperature on the tube, max ............................................ 200 O C TYpical operation carrier conditions Maximum ratings Anode voltage ....................................... 15 kV Control-grid voltage ............................- 800 V Screen-grid voltage ..............................1 .2 kV Peak cathode current ............................400 A Anode dissipation .......... . . . . . . . . . . . O kW Control-grid dissipation .......................... 2 kW Screen-grid dissipation ..........................5 kW ( 1 ) Thomson Tubes Eleclroniques defines the operaling voltage according to each parficular siluation As an ind~cationfor equipment design purposes only a heater voltage of 15 V produces a heating currenl of 500 A (2) Values for c o o l ~ n gg i v e n for m a x i m u m a n o d e d~ssipation output power 300 kW Frequency 30 MHz Anode voltage 14 kV Screen-grid voltage 1O00 Control-grid bias voltage - 550 v v Anode current 25 A Screen-grid current 1.5 A Control-grid current 1 A 1,\ THOMSON TUBES ELECTRONIQUES TH 576 AM tetrode i Output power 550 kW in SW, up to 50 MHz General characteristics Cathode ...................................................................t h o r i a e t u n g ~ t e n Heating (1) ..................................................direct, dc or single phase Interelectrodes capacitances, approx.: cathode-control grid ............................................................. 687 pF control grid-screen grid ........................................................ 814 pF control grid-anode ............................................................... 10 pF screen grid-anode ................................................................ 142 pF Amplification factor, average .................... . ................................... 5 600 mA/V Transconductance (la = 35 A, Vg2 = 1000 V) ...................... Operating position ............................. ............ v e c a anode up Weight, approx ........................................................................... 110 kg Dimensions ................................................................ page 55 Connecter ............................................................................... 16138 Anode cooling (2) .........................................................Hypewapotron water flow, min ............................................................... 300 llmn 5 bar water inlet pressure, max ........................................................ .......... 80 ' C outlet water temperature, less than ................... Electrode terminal and ceramic cooling: .................................................. type ....................... . . foced air O "C temperature on the tube, max ........................................... . . . . . T Y P ~ operation c~~ carrier conditions Maximum ratings Anode voltage ...................................... .15 kV Control-grid voltage ..........................- 1000 V Screen-grid voltage .................... ....... 2 kV Peak cathode current .............. . .........650 A . ...........800 kW Anode dissipation ................ Control-yrid dissipation ..........................4 kW Screen-grid dissipation ........................ 12 kW ( 1 ) Thomsoi? Tubes Eiectro~iiquesdefines the operahng voltage according Io each paiticular situatfon As an indication for equipment design purposes only a heater voltage of 19 V produces a heating currenl of 1000 A ( 2 ) Values for c o o l f n g g l v e n f o r m a x i m u m a n o d e dissipation output power 550 kW Frequency 30 MHz Anode voltage 15 kV Screen-grid voltage 1200 V Control-grid bias voltage - 800 V Anode current 39 A Screen-grid current 7 A Control-grid current 2 A ANI tetrode i Output 7 power 125 kW in MW and SW, up to 50 MHz General characteristics Cathode ................................................................... thoriated tungsten direct, dc or single phase Heating (1) ................................................... lnterelectrodes capacitances, approx.: cathode-control grid ............................................................. 180 pF control grid-~creengrid ........................................................ 310 pF control grid-anode ................................................................. 2.3 p i screen grid-anode .................................................................. 47 PF Maximum ratings Amplification factor, average .............................................................. 5 Anode voltage .......................................15 kV Control-grid voltage ............................- 800 V Transconductance (la = 25 A, Vg2 = 1000 V) ......................140 mA/V ..............................1.2kV Operating position .................................................... veflical, anode up Screen-grid voltage ............................160 A Peak cathode current ............................................................................. Weight, approx 35 kg ............................... Anode dissipation 150 kW Dimensions ......................................................................S page 55 Control-grid dissipation .......................0.8 kW Connecter ..........................................................................TH 16111 Screen-grid dissipation ..........................2 kW Anode cooling (2) ......................................................... Hypervapotron water flow, min .................................................................... 70 I/mn 5 bar (1) Thomson Tubes Electroniques defines the operatlng water inlet pressure, max ....................................................... voltage according Io each particular situation As an outlet water temperature, less than ....................................... 8 "C indication for equipment design purposes only a lieater voltage of 10 V produces a heating current of 280 A Electrode terminal and ceramic ~00ling: type .......................................................................... .....forced air (2) Values for cooling g i v e n for maxlrnum anode dissipabon 200 OC temperature on the tube, max .............................................. Typical operation carrier conditions 1 50 o u t p u t power 125 kW Frequency 30 MHz Anode voltage 14 kV Screen-grid voltage 1O00 Control-grid bias voltage - 550 v v Anode current 10.5 A Screen-grid current 0.8 A Control-grid current 0.9 A lHOMSON TUBES ELECTRONIQUES UHF tetrode i Output power up to 22 kW peak-of-sync in common amplification 10.5 kW peak-of-sync in common amplification General characteristics Cathode ............................................................... thorated tungsten Heating (1) ............................................. direct dc or single phase Interelectrodes capacitances, approx.: cathode-control grid ............................................................... 72 pF control grid-screen grid .......................................................... 93 pF screen grid-anode ............................................................. 13.2 pF Amplification factor, average .........................................................8 Transconductance (la = 2 A, Vg2 = 300 V) ............................80 m A N Operating position .................................................... v e i c a anode up ..................................................4 1 kg Weight, approx ................ . . Dimensions .......................................................................s e page 55 Anode cooling (2) .......................................................... Hypervapotron water flow, min ................................................................. 15 I/mn water inlet pressure, max ..................... . ...............................5 bar outlet water temperature ...................................................... 80 "C Screen grid terminal cooling ........................................................ water water flow, min .............................................................. 1.5 l/mn Electrode terminal and ceramic seal cooling type ............................................................................... f o r c e air temperature on the tube, max ..............................................300 OC .. Maximum ratings Frequency ...................................... 1000 MHz 7.5 kV Anode voltage ...................................... Anode current ................................ .... A Anode dissipation ................. . .........25 kW Control-grid dissipation ..........................50 W Screen-grid dissipation ........................ 120 W ( 1 ) Thomson Tubes Electron~quesdef~nesthe operating voltage according to each parf~cularsftuatlon As an indication for equlpment deslgn purposes only, a heater voltage of 4 2 V produces a heating current of 146 A (2) Values for cooling given for maximum anode dissipation T ~ ~ i coperation al at 700 MHz in the matched cavity TH 18582 Common amplification Vision only Peak-of-sync output power 10.5 22 kW - 12.5 12.5 MHz 1 d B bandwidth - 48 lntermodulation products dB Gain 15 15.1 dB Anode voltage 5.5 7.3 kV Screen-grid voltage 600 800 V Anode current, with signal 3.45 4.3 A 1.5 1.6 A Screen-grid current Control-grid current , Anode current at zero signal I I I I I I i TH 18582 matched circuit assembly For UHF-TV transmitters and translators (Bands IV and V) Operating frequency .................................................478 to 860 MHz Dimensions .......................................................1092 x 322 x 285 mm Weight, approx (without tube) ................................................ 70 kg RF connections. input .....................................................femae type N, LC or 7/16" output ....................................standard EIA 3 118" rigid coaxial line Cooling ................................................... Hypeapotron and forced air 1 I ri, UHF tetrode Output power up to 2.2 kW peak-of-sync in common amplification 4.4 kW peak-of-sync in vision carrier amplification 2.5 kW in sound carrier amplification General characteristics Cathode ................................................................... thoriated tUngSten Heating ( 1 ) ......................................................................................... lnterelectrodes capacitances, approx.: cathode-control grid ............................................................... 5 pF control grid-screen grid ......................................................... 72 pF screen grid-anode .................................................................... 9 PF ........................... 8 Amplification factor, average ................... 60 mAiV Transconductance (la = 2 A, Vg2 = 300 V) ......................... Operating position ...........................................v e i c a anode up Weight, approx ............................................................................ 2 9 kg Dimensions .......................................................................... page 55 Anode cooling (2) ..........................................................Hypervapotron water flow, min ................................................................... 6 Ilrnn water inlet pressure, max ................................................ 5 bar outlet water temperature, less than .......................................80 "C Electrode terminal and ceramic seal cooling type ........................................................................................air 300 "C temperature on the tube, max .......................................... . . . . Maximum ratings Frequency ......................................1000 MHz Anode voltage .........................................6 kV Anode current ...........................................3 A . ...............1 O kW Anode dissipation ........... Control-grid dissipation .......................... 25 W Screen-grid dissipation ........................ 75 W (1) Thomson Tubes Electroniques defines the operating voltage according to each parficular situation As an indication for equiprnent design purposes only a heater voltage of 6 Vproduces a heabng currenf of 65 A (2) Values for cooling given for niaxirnum anode dissipation Common Sound amplification only Typical Operation at 800 MHz in the matched cavity TH 18565 TH 18565 I I 2.2 -1 dB bandwidth Intermodulation products Gain Anode voltage Screen-grid voltage Anode current, with signal Screen-grid current Control-grid current Anode current at zero signal 11.5 - 52 16 5.5 600 1.6 10 negl. 0.9 4.4 11.5 11.5 kW kW MHz 16 5 500 16 5 700 2 15 1 0.9 dB dB kV V A mA mA A 2.5 2 30 5 0.85 matched circuit assembly For UHF-TV transmitters and translators (Bands IV and V) 1, I Peak-of-sync output power Sound carrier output power Vision only ". L. Operating frequency .................................................... 470 to 860 MHz Dimensions ........................................................ 826 x 250 x 260 mm Weight, approx (without tube) ..................................................... 34 kg RF connections: input ...................................... :................................ f e m a e type N output ......................................................standard EIA 1 5/8" Cooling ................................................ ypervapotron and forced air 52 .*- .. ,,\ THOMSON TUBES ELECTRONIQUES AM tetrode TH 598 Output power 3kW up to 120 MHz General characteristics Cathode ................................................................... thoriated tungsten Heating (1) ....................................................direct, dc or single phase Interelectrodes capacitances, approx.: cathode-control grid ............................................................... 40 PF control grid-screen grid ..........................................................75 pF control grid-anode .................................................................0.4 pF screen grid-anode ...............................................................11.5 pF Maximum ratings Anode dc voltage ................................... 5 kV Amplification factor, average ............................................................ 7 Control-grid voltage .......................... - 200 V Transconductance (la = 1.5 A, Vg2 = 600 V) .........................40 mA/V Screen-grid voltage ............................. 800 V Operating position .....................................................................vertical Peak cathode current .............................. 10 A Weight, approx ............................................................................... 3 kg Anode dissipation ................................ 5 kW Dimensions ....................................................................see page 55 Control-grid dissipation ..........................40 W Anode cooling (2) .........................................................Hypewapotron Screen-grid dissipation ........................100 W water flow, min ...................................................................... 2 Ilmn water inlet pressure, max ........................................................ 5 bar outlet water temperature ......................................................0 0 "C Electrode terminal and ceramic cooling: air type ........................................................................................ 250 OC temperature on the tube, max ........................................... T ~ ~ i coperation al carrier conditions voltage according to each particular s~tuatron As an indication for equipment design purposes only a heater voltage of 6 V produces a heating current of 50 A ( 2 ) Values for cooling g i v e n for m a x i m u m a n o d e dissipation o u t b u t power 3 kW Frequency 30 MHz Anode voltage 4.5 kV Screen-grid voltage 750 V Control-grid bias voltage - 120 V 1 A Screen-grid current 1O mA Control-grid current negligible Anode current THOMSON TUBES ELECTRONIQUES ( 1 ) Thomson Tubes Electroniques defines the operating 53 Power-grid tubes Tube dimensions 54 ,,\ THOMSON TUBES ELECTRONIQUES THOMSON TUBES ELECTRONIQUES 1. INFORMATIONS TECHNIQUES PREWIfaRE PARTI Z 1. INFORMATIONS TECHNIQUES Le fonctionnement des tubes à grille est basé sur un déplacement d'électrons d'une source, la cathode, vers un collecteur, I'anode. La quantité d'électrons est modulée dans le temps par une ou plusieurs grilles. Si l'on applique dans une diode, c'est-à-dire dans un tube qui n'est constitué que d'une cathode et d'une anode, une tension positive croissante entre ces deux electrodes, on obtient une courbe caractéristique : Généralement, le courant n'atteint pas un palier car l'effet du champ électrique (effet SCHOTTKY) n'est pas négligeable. Les tubes fonctionnent dans la zone de charge d'espace. L'allure de la courbe caractéristique est déterminée par les paramètres géométriques du tube. Le rapport : est appelée p e r v é a n c e et ne dépend que des dimensions mécaniques des éléments du tube. Les triodes sont des tubes à vide constitués d'une cathode, d'une grille et d'une anode. La grille, placée entre cathode et anode, contrôle le flux d'électrons qui se déplace entre ces deux électrodes. Elle agit par son champ électrique et doit capter le moins possible les électrons émis par la cathode. 0, 73 O C -s m C 3 6 100083-111 O' - rlCJiil~ -- -- Tension d'anode (Va) - -- -- f' ---- 1/16' /, ti( -- - La partie de la courbe caractéristique, dans laquelle le courant électronique croît rapidement en fonction de la tension est appelée zone de charge d'espace. En effet, la présence d'électrons au voisinage de la cathode mod~fiele champ électrique produit par I'anode. Le courant varie comme la puissance 312 de la tension selon la loi de LANGMUIR: La tension continuant d'augmenter, la cathode atteint sa saturation qui est fonction de la température et de la nature du corps émissif. Le courant de saturation par u n i t é de surface e s t d o n n é p a r l a f o r m u l e d e RICHARDSON-DUSHMANN: Lorsque, la tension d'anode étant positive, la tension grille est suffisamment négative, le potentiel est négatif au voisinage de la cathode et aucun électron ne peut passer ; la et Ig sont nuls. Lorsque la grille devient moins négative, les électrons émis par la cathode atteignent I'anode et la commence à apparaître (voir figure 2 ) . Enfin, lorsque la grille devient positive, le courant émis par la cathode continue à croître, mais une partie de ce courant est captée par la grille. La figure 2 montre qu'avec de faibles variations de la tension de grille, on peut provoquer des variations i m p o r t a n t e s du c o u r a n t d ' a n o d e . C ' e s t l ' e f f e t fondamental : il permet, en introduisant des circuits convenables dans la grille et dans I'anode, de réaliser des amplificateurs et des oscillateurs. Cette action spécifique de la grille lui a fait donner le nom de grille de commande. Les courants la et 19 sont fonction des tensions Va et Vg. Leur représentation se fait habituellement en WS est le travail d'extraction des électrons du corps émissif, T est la température de la cathode, k est la constante de BOLTZMANN, A est la constante de RICHARDSON. attribuant à l'un des trois paramètres la, Va, Vg, une suite de valeurs fixes et en traçant le réseau des courbes qui relient les deux autres paramètres entre eux. Trois configurations sont ainsi possibles, dont la plus utilisée est le réseau Vg = f(Va) à la constant, connu sous le nom de caractéristiques à courant constant. A ce réseau, on I I l I. INFORMATIONS TECHNIQUES observe effectivement, comme le montre la figure 3. Si la tension d'anode est faible et la tension de grille élevée, la forme du réseau est modifiée par la présence d'un courant de grille important (partie gauche du réseau de la figure 3). -1 - Trois paramètres principaux caractérisent le fonctionnement de la triode: Le coefficient d'amplification p, nombre sans dimension, est égal à I'inverse de la pente des courbes à la constant sur le réseau Vg-Va. constante ,$te 2coJB "9 Tension de grille (Vg) ajoute généralement le réseau à 1g constant (figure 3). La notion de diode équivalente, d'après laquelle la ne dépend que de Vg + Vaiy (y étant le coefficient d'amplification du tube, égal à AVaJAVg pour la donné), laisse prévoir que le réseau à la constant se compose de droites parallèles de pente - 1 1 ~ .C'est ce qu'on * La pente s est le rapport de la variation du courant d'anode à la variation de la tension de grille de commande (réseau à Va constante). Elle se mesure en mAN. La résistance interne Ri représente I'inverse de la pente des,courbes à Vg constante sur le réseau la-Va ; elle se mesure en ohm. Le p a r a m è t r e p d é p e n d , p e u d u p o i n t de fonctionnement, sauf lorsque le courant de grille est important; il caractérise donc la triode. Par contre, s et Ri ne peuvent être spécifiés que pour un point de fonctionnement donné. En régime dynamique, le couplage capacitif grille-anode limite les performances des triodes. Pour pallier cet inconvénient, une seconde grille a été intercalée entre la grille de commande et l'anode. Son rôle d'écran électrostatique, qui réduit la capacité grille de commandelanode, lui a donné son nom: la grille-écran. Figure 3 - ;:c?rira,-:Cr~::t~c;i 'es ,i coliranr constant d'iinf:tr;ode I 1. INFORMATIONS TECHNIQUES Les paramètres fondamentaux qui caractérisent le fonctionnement de la tétrode sont : Dans la tétrode, la grille de commande a le même rôle que dans une triode; cependant la grille-écran, portée à un potentiel positif, engendre par l'influence de son champ un courant électronique dont la majeure partie atteint l'anode. Les variations de la tension d'anode ne sont pas totalement sans influence sur le courant d'anode, mais le phénomène est très atténué. On a ainsi séparé les fonctions générateur d'électrons et collecteur d'électrons. La maîtrise du potentiel de la grille-écran est très importante. En effet, toute surface bombardée par des é l e c t r o n s émet, s e l o n s a n a t u r e et l e s caractéristiques du faisceau incident, des électrons secondaires. Si le matériau qui constitue la grille n'a pas un coefficient d'émission secondaire très faible, le courant de grille-écran sera mal contrôlé et pourra entraîner des difficultés de fonctionnement ou de mise en oeuvre du tube. Le réseau le plus couramment utilisé est le réseau à courant constant, tracé pour une tension de grille-écran donnée: Vgl = f(Va) la et Vg2 constants * le coefficient d'amplification pg1g2, nombre sans dimension, égal au rapport des variations de tension de la grille-écran et de la grille de commande à courant d'anode constant: Avg2 pg1g2 = la et Va constants AVgl la pente s, en mAN, rapport de la variation du courant d'anode sur la variation de tension de grille de commande en un point donné du réseau : Aia s=* Va et Vg2 constantes AVg1 * la résistance interne Ri, rapport de la variation de la tension d'anode à la variation du courant d'anode à tensions de grille de commande et de grille-écran constantes, exprimée en ohm : AVa Ri = -Vg1 et Vg2 constantes Ala pglg2 est la principale caractéristique d'une tétrode. La pente est donnée à titre indicatif, car sa valeur dépend du point de mesure choisi. -1 II UTILISATION DES TUBES DANS LES EMETTEURS DE RADlODlFFUSlON II. UTILISATION DES TUBES DANS LES EMETTEURS DE RADIODIFFUSION 1 l \ L'évolution rapide des technologies (tubes, circuits électroniques) autorise les constructeurs d'équipements à proposer des émetteurs de forte puissance de plus en plus performants et plus faciles à exploiter. Parallèlement, THOMSON a développé dans son Département Tubes à Grilles de Puissance, puis intégré dans ses fabrications, deux technologies originales (le graphite pyrolytique et le refroidissement par système Hypervapotron@)qui ont permis d'optimiser l'utilisation des tétrodes. Fonctionnement à des fréquences élevées (bande O.C.). " Energie consommée réduite grâce à l'utilisation de nouveaux systèmes de modulation et à l'utilisation plus fréquente du système de transmission B.L.U. ' Réduction du nombre de tubes 1 Ce matériau a modifié totalement la structure interne des tubes en conduisant à la réalisation de grilles PyroblocQ.Ses principaux avantages sont: * très bonne définition géométrique, conduisant à un parfait alignement grille de cornmandelgrille-écran (réduction des courants de grille-écran), b, 1 Pour choisir un tube, le concepteur d'un émetteur radio doit considérer les facteurs suivants: * La puissance que doit fournir le tube à l'antenne; les 1 ( La linéarité dont dépend le taux de distorsion ou d'intermodulation. * La tenue aux hautes tensions nécessitées par les puissances et rendements élevés. " Le gain qui permet de limiter le nombre de tubes dans un émetteur. * Les capacités interélectrodes qui influent sur les facteurs cités ci-dessus (gain, linéarité, rendement). La tenue aux surcharges de puissance etlou tension provoquées par tout incident de fonctionnement. La recherche constante de l'amélioration de ces facteurs a conduit à l'adoption des tétrodes au détriment des triodes dans les émetteurs de puissance. coefficient de dilatation négligeable, permettant d'obtenir des distances interélectrodes faibles et reproductibles (meilleur gain et meilleure tenue aux hautes tensions). "rande tenue mécanique à haute température (bonne résistance aux surcharges). * émetteurs modernes n'utilisent généralement qu'un seul tube en étage final. Le rendement qui peut être atteint, compte tenu du mode de fonctionnement retenu pour le tube (classe de fonctionnement. amplification HF ou BF. émetteurs DBL ou BLU ...). 1 1 Les caractéristiques les plus demandées sont : @ 1 @ conductibilité thermique élevée et pouvoir émissif proche de celui du corps noir, donc excellentes possibilités de dissipation (faibles tensions de déchet, d'où rendement amélioré). faible coefficient d'émission secondaire (linéarité accrue). Lr systc rne H y p o 9,trp,tron ' L'adoption du refroidissement d'anode par vaporisation-condensation de vapeur in-situ a permis : V e réduire l'encombrement de l'ensemble tubelrefroidisseur, ce qui diminue les capacités parasites anodefmasse. de repousser les limites de dissipation maximale d'anode loin des conditions de fonctionnement nominales. Ces deux technologies réunies ont autorisé, à puissance donnée, la réalisation de tubes de plus faibles dimensions. Les tubes peuvent donc fonctionner à des fréquences plus élevées. La pente des tubes qui devrait diminuer en raison des surfaces réduites de la cathode et des grilles, est conservée grâce aux distances interélectrodes plus faibles. a II. UTILISATION DES TUBES DANS LES EMETTEURS DE RADlODlFFUSlON Conditions recherchées Fonctionnement dans la bande O.C. Gain Triodes Tétrodes Difficile ( capacité grille-anode élevée) Facile Limité par la capacité grille- anode Elevé Limité par la puissance dissipable sur la grille Elevé Faible tension de déchet Médiocre Bonne Limité par la puissance dissipable sur la grille Facile l 1 1 I Rendement anodique Linéarité Fonctionnement en étage HF modulé 111. TECHNOLOGIE 1 - III. TECHNOLOGIE - Le choix du tungstène thorié est lié à son excellente tenue en haute tension. La cathode en tungstène thorié constitue une version améliorée de la cathode en tungstène pur qui présente l'inconvénient de fonctionner à température très élevée, conduisant à une grande vitesse d'évaporation. En déposant une couche monoatomique de thorium à la surface du tungstène, on peut obtenir une densité d'émission satisfaisante avec une température considérablement abaissée (de 1900 à 2000 "K). La cathode prend la forme d'une "cage" cylindrique (voir figure 5) dont les brins sont chauffés directement par passage du courant. Cette structure cylindrique est constituée par une sorte de grillage obtenu en soudant en leurs points d'intersection deux ensembles de fils disposés obliquement sur un cylindre. Ce cylindre est soudé à ses extrémités sur des plateaux qui servent d'amenées du courant de chauffage. de tungstène qui permettra, au cours du fonctionnement du tube, la réduction de la thorine et la diffusion du thorium vers la surface, la couvrant d'une couche monoatomique. On obtient ainsi des cathodes dont le taux d'évaporation de thorium est plus bas que celui des cathodes non carburées, ce qui permet de les faire fonctionner à température plus élevée et avec des densités de courant plus fortes. Elles résistent é g a l e m e n t mieux aux g a z r é s i d u e l s et a u bombardement ionique. Cette résistance est beaucoup plus grande que celle des cathodes à oxydes, ce qui fait préférer les cathodes en tungstène thorié pour les tubes de puissance fonctionnant à des tensions élevées, en dépit de la puissance de chauffage plus importante qu'elles exigent. La forme de la grille, sa distance à la cathode, et dans une moindre mesure à l'anode, déterminent le réseau de caractéristiques d'une triode. La nécessité de réduire au maximum le courant capté par la grille conduit par ailleurs à réaliser des grilles très transparentes, c'est-à-dire dont les parties pleines sont petites par rapport à la surface totale. Enfin, la recherche d'une commande efficace et d'un fonctionnement à fréquence élevée conduit à des distances faibles entre grille et cathode. Dans la tétrode, la réduction du courant de grille-écran impose d'aligner parfaitement cette grille et la grille de commande de façon que les électrons passant à travers la première grille aient également une bonne probabilité de passer à travers l a seconde. D'autre part, la nécessité d'avoir une tension d'écran nettement moins élevée que la tension d'anode conduit à une distance faible entre grille de commande et grille-écran. Le fil utilisé, de quelques dixièmes de millimètre de diamètre, est un fil de tungstène contenant un faible pourcentage de thorine. Pendant l'opération de carburation, la cathode est portée à haute température, dans une atmosphère d'hydrocarbure à basse pression. Ce procédé crée en surface du fil une gaine de carbure Pour les raisons analysées plus haut, l'utilisation de matériaux conventionnels ne constitue pas une solution satisfaisante pour la fabrication des grilles des tubes modernes de plus en plus puissants et compacts. C'est pourquoi THOMSON TUBES ELECTRONIQUES a orienté ses recherches, il y a plus de 20 ans, dans une voie originale et a développé un nouveau matériau, le graphite pyrolytique, et un nouveau type de grille, la grille Pyroblocm. Le graphite pyrolytique, aussi appelé graphite orienté, est essentiellement un graphite cristallisé obtenu par décomposition thermique d'un hydrocarbure gazeux sur 111. TECHNOLOGIE la surface d'un matériau porté à une très haute température sous ambiance contrôlée. Une couche de graphite pyrolytique est ainsi déposée, dont l'épaisseur dépend de la durée et des paramètres de dépôt. De même, les conditions dans lesquelles s'effectue le dépôt influent sur la structure et les propriétés mécaniques du graphite. Les qualités essentielles du graphite pyrolytique peuvent être groupées en quatre catégories ; elles prouvent qu'il est le meilleur matériau qui puisse être utilisé pour la fabrication des grilles des tubes de grande puissance: 5 9 -5 De plus, l'excellente résistance aux chocs thermiques et la grande stabilité du graphite pyrolytique aux hautes températures autorisent les grilles Pyrobloc@à subir sans dommage des anomalies de fonctionnement de faible durée, contrairement aux grilles conventionnelles qui seraient définitivement détruites dans des conditions de surcharge similaires. L'une des plus importantes qualités du graphite pyrolytique réside dans sa très grande capacité de rayonnement thermique, très proche de celle du corps noir théorique. Propriétés émissives II est bien connu que le graphite présente des effets d'émission secondaire bien plus faibles que d'autres matériaux tels que le molybdène, le tantale ou le tungstène. De plus, l'émission thermique est forcément réduite, grâce à l'abaissement de la température de fonctionnement de la grille, rendu possible par la bonne conductibilité thermique du graphite. 5.10" O C al s al .-g 10.' E --2 5.10'~ .al .- O Y U 3 2 O 10'~ O 5.10." 1 Grâce à ces propriétés, la chaleur dissipée sur la grille peut être facilement transférée vers les structures de support. Ce transfert est d'autant plus aisé que la grille Pyrobloc@est réalisée d'une seule pièce, contrairement aux autres grilles comportant des points de soudure. La figure 7 montre que le coefficient de dilatation thermique linéaire du graphite pyrolytique dans la direction parallèle au plan de dépôt (ab) est faible. II s'ensuit une variation négligeable du diamètre de la grille Pyrobloc@,ce qui permet de réaliser un espace interélectrode extrêmement faible, condition exigée pour les tubes fonctionnant à très haute fréquence. 1 2 -2 Propriétés thermiques La figure 6 montre la conductibilité thermique de divers matériaux en fonction de la température. On peut remarquer que la conductibilité thermique du graphite pyrolytique dans une direction parallèle au plan de dépôt (ab) est très élevée, du même ordre que celle du tungstène et du cuivre. Par contre, dans la direction (c) perpendiculaire au plan de dépôt (ab), la conduct~bilité thermique est très faible, inférieure à celle de la zircone stabilisée. 100083-511 1O -273 O 500 1O00 1500 2000 2500 3000 Température en "C Figure 6 - Condi~ctibiiitetherri~~que des divers n7aterialix d~ grille 100083-611 25 2 L m a L? 4 --, al 20 O .-2 (O 'C .- 15 al 1 0 Eal + -.- 10 C .-O a m 73 al -0 5 C .-w -w ,-O O O -273 O 500 1000 1500 2000 2500 3000 Température en "C F i g u r ~7 - Coefficient de d ~ l a itiorl t '7er17iiqiie des d~versmaferiniix (regi !e 1 I I 1 I 1 I 1 I 1 I lll. TECHNOLOGIE Propriétés mécaniques Fabrication des grilles pyrobloc@ Les propriétés mécaniques du graphite pyrolytique sont nettement supérieures à celles des matériaux utilisés jusqu'à ce jour, comme en témoignent les chiffres suivants : Pour aboutir à la fabrication industrielle des grilles Pyrobloc@,un grand nombre d'obstacles a dû être surmonté. L'une des difficultés pratiques rencontrée était l'impossibilité de trouver sur le marché des qualités de g r a p h i t e a s s e z pur pour s a t i s f a i r e aux caractéristiques exigées. Ce problème a été résolu en utilisant le procédé de dépôt de graphite pyrolytique à haute température décrit plus haut, pour réaliser une ébauche de grille. A partir de cette ébauche, on réalise une grille à mailles croisées ou parallèles (voir figure 9); grâce à un procédé original, on peut fabriquer toutes sortes de grilles à mailles fines avec des brins de section aussi faible que 0,01 mm2. Résistance à la flexion, dans le plan (ab) : 1700 kg/cm2 Résistance à la traction, dans le plan (ab) : 1100 kg/cm2 a Résistance à la compression, dans le plan (ab) : 1500 kg/cm2 * Résistance à la compression, direction (c) : 5000 kg/cm2 Contrairement à d'autres matériaux, la résistance mécanique du graphite pyrolytique augmente avec la température. Grâce à l'excellente stabilité à haute température (la pression de vapeur à 1850 OC est de 10.' torr), la grille peut fonctionner à une temperature égale à celle d'une cathode en tungstène thorié. ' Propriétés électriques L'anisotropie électrique est liée à la structure cristallographique du matériau, ce qui se traduit par une différence de résistivité électrique entre la direction parallèle au plan (ab) et la direction (c). (figure 8). De plus, la résistivité électrique dans le plan (ab) reste pratiquement constante, égale à sa valeur minimale dans des conditions de températures normales des tubes à grille. A haute température, le graphite pyrolytique est aussi bon conducteur que le tungstène ou le molybdène, ce qui limite l'échauffement par effet Joule. - - --- - - ---y" - --------:O0083 7 1 5.10.' 1 Figure 9 - G/!:ieP L;obioc d une tetrode 1 O-' 5.1 On obtient ainsi des grilles sous forme monobloc. Autrement dit, tous les éléments (le dôme, le maillage, l'embase) forment une structure continue sans points de soudure ni assemblage mécanique. Cette technique originale et tous ces procédés de fabrication, qui ont fait l'objet de brevets THOMSON TUBES ELECTRONIQUES, ont permis de franchir une étape décisive dans la réalisation de grilles Pyroblo6' destinées aux tubes de grande puissance. 1 5.1 1 5.IO'" 1 0-4 5.1 1O-" 5.1 1 5.10.' 1 O-' 5.10.' 1 -273O L'anode des tubes de puissance est une électrode en cuivre qui enveloppe l'ensemble des autres électrodes. 500 1000 1500 2000 2500 3000 Température en O C Figure 8 - R e s i s t i ~ ~i,iecliiqcic ~té dcs divers I rni7iei57~ix JE gt:!/e 1O Son rôle est multiple: elle collecte les électrons, transmet l'énergie dissipée, assure l'échange thermique et participe à l'étanchéité au vide du tube. Sa forme et ses dimensions sont essentiellement déterminées par la puissance qu'elle doit dissiper. 111. TECHNOLOGIE Pendant le fonctionnement du tube, I'anode est portée à une tension élevée; l'isolement électrique avec les dispositifs de refroidissement, généralement à la masse, devra être respecté. Pour les niveaux de puissance couramment utilisés dans les émetteurs de radio-diffusion, le refroidissement de I'anode nécessite des modes de refroidissement très efficaces, notamment la convection forcée de I'air et les systèmes Supervapotron et HypervapotronQ. Refroidissement par air forcé Les anodes refroidies de cette manière sont munies d'ailettes (figure I O ) , ce qui augmente la surface d'échange entre le fluide de refroidissement et I'anode. L'efficacité du refroidissement est encore accrue par une augmentation de la vitesse de I'air (30 m/sec.par exemple). Un échange thermique efficace est obtenu par la vaporisation directe de I'eau en contact avec une anode comportant des protubérances massives. La vapeur d'eau est canalisée puis condensée dans un circuit extérieur. Le refroidissement anodique d'un Supervapotron est assuré pour autant que l'anode demeure en contact avec I'eau, ce qui oblige à respecter un niveau d'eau minimum. L'emploi d'une installation Vapodyne assure le maintien du niveau d'eau entre les limites admises, la condensation de la vapeur en circuit fermé et l'évacuation de la chaleur. Cette installation doit être vérifiée, conformément à la notice particulière du tube utilisé. L'air est canalisé sur les ailettes, le débit d'air étant obtenu par un ventilateur dont les caractéristiques doivent respecter les consignes de débit et de pression indiquées pour le type de tube concerné. Ce dispositif présente l'avantage d'assurer de façon simple l'isolement de I'anode. Les inconvénients sont liés à l'utilisation d'un ventilateur parfois bruyant et qui consomme une énergie non négligeable; de plus, la nécessité d'augmenter la surface d'échange de I'anode conduit à des tubes plus lourds. Le refroidissement par HypervapotronQ (figure 11) constitue le dernier perfectionnement apporté à l'effet V a p o t r o n d é c o u v e r t par T H O M S O N T U B E S ELECTRONIQUES il y a plus de 30 ans. L'effet Hypervapotron@réside dans la combinaison de deux phénomènes : La dissipation maximale de ce type de refroidissement est de l'ordre de 20 kW. * Figure 10 - Tube à refroidissement à ail d'une part, l'ébullition stable et complexe à l'intérieur de fentes étroites dans la structure extérieure de I'anode. Figure I I - Tube ,. refv dissement par lc systenlc h1/per ipOilOl? , 111. TECHNOLOGIE d'autre part, la condensation immédiate de la vapeur expulsée des fentes par un courant d'eau perpendiculaire à celles-ci et circulant à l'intérieur d'une chemise coaxiale. La figure (12) illustre cette technique. La vapeur se forme dans la fente (figure 12a), s'en échappe à grande vitesse (figure 12b), puis est immédiatement condensée par le courant d'eau. La fente est réalimentée en eau par aspiration entre deux jets de vapeur (figure 12c). *n Circulation d'eau Pellicule \ 2 kWlcm2 en régime continu. Les tubes électroniques Hypervapotron travaillent aux environs de 300 W/cm2, donc avec une très grande marge de sécurité. Les isolateurs céramiques d'un tube de puissance a grille (figure 13) doivent assurer de nombreuses fonctions : une isolation électrique entre les différents collets (sortie d'électrodes), une étanchéité parfaite, une bonne tenue mécanique à des températures de fonctionnement élevées. Les céramiques, à haute teneur en alumine, satisfont les critères précédents et permettent le développement de tubes plus puissants ou travaillant à tension plus élevée. Leurs principales propriétés physiques sont : 1 Liquide ,/fl Chemise d'eau Rigidité diélectrique : 20 kV/mm Conductibilité électrique à 20 OC : < 1 Cl -'m.' Angle de perte à 1 MHz: tg a G 1 0 . ~ Figure 12 - Pr1r7c1ped c foi?ctionni ~ ~ i e idi] - i ! systeme - HV;l( ~ r v ~ ~ ~ ~ o f ~ o / ~ La condensation instantanée de la vapeur réduit les effets perturbateurs causés par le volume de vapeur engendré et élimine l'emploi d'un condenseur externe. La température de sortie de l'eau de refroidissement n'est pas primordiale pour autant qu'elle demeure au-dessous de 100 OC à la pression atmosphérique. L'eau chaude à la sortie du système peut être utilisée par l'intermédiaire d'un échangeur eau-eau pour le chauffage de bâtiments ou pour d'autres applications. Des essais de dissipation ont permis d'atteindre Bonne conductibilité thermique (30 W m.' OC-') entraînant une bonne résistance aux chocs thermiques. Bonne tenue mécanique à température élevée (le point de ramollissement n'apparaît qu'à 1600 O C ) . Les procédés d'usinage par rectification permettent de respecter des tolérances sévères et d'obtenir une précision déterminante pour la qualité des tubes à structure coaxiale. Les scellements céramique-métal obtenus par un procédé sophistiqué permettent d'atteindre des températures d'utilisation élevées sans conséquences sur la durée de vie du tube. , IV. CONNECTEUR IV. CONNECTEUR Le débit et la pression de I'air doivent être conformes à la notice afin que la température des collets, scellements céramique-métal et céramiques ne dépassent pas la température maximale définie dans la notice particulière du tube. Les tubes électroniques sont prévus pour être montés en position verticale sur un support approprié, le connecteur (figure 14), dont le but est de permettre la liaison avec les électrodes et le refroidissement par ventilation forcée des collets (sorties d'électrodes) et des céramiques. L'ensemble tube/connecteur a été étudié afin d'assurer le fonctionnement du tube aux fréquences élevées. La connexion des électrodes est assurée par des contacts en cuprobérylium. Leur élasticité permet une bonne pression de contact et le passage de courants élevés. L'air de refroidissement est canalisé par le connecteur sur les collets. Ceux-ci sont percés pour que I'air refroidisse efficacement les scellements céramique-métal. + Plan de référence ------ Anode 1/ Trous de Grille de commande Filamentcathode Filament Eclateur Grille écran Figure 14 - Coiij)e d'un connilcteor dc, tetrode . Un positionnement correct du tube dans le connecteur est impératif. Compte tenu de son poids, le tube doit être supporté par le collet d'anode; le plan de ce collet est pris comme plan de référence et la position du connecteur doit être déterminée par rapport à ce plan. Dans ces conditions, une ventilation correcte est obtenue car les trous de passage d'air des collets ne sont pas obstrués et la connexion des électrodes est réalisée dans les zones de contact indiquées dans la notice. * Des précaut~onssont à prendre lors de la mise en place et du retrait des tubes afin que les contacts ne soient pas aplatis ou arrachés, ce qui augmente la résistance du contact électrique, d'ou risques d'échauffement et de destruction des sorties d'électrodes du tube. Une ventilation incorrecte des électrodes provoque l'échauffement des contacts et la perte de leur élasticité. II est nécessaire de vérifier périodiquement l'état des contacts. ' Le connecteur comporte des découplages cathodelmasse et grille-écranlmasse, réalisés en Kapton* métallise sur les deux faces, ce qui permet d'obtenir de fortes valeurs de capacité avec des tensions d'isolement élevées. Ces capacités peuvent cependant ne pas être suffisantes en basse fréquence. II est alors nécessaire de les compléter par des condensateurs appropriés. Des éclateurs grille de commande/masse et grille-écranlmasse, réglés en usine, participent à la protection du tube en limitant les surtensions accidentelles sur les électrodes. ' KAPTON Brevet DUPONT de NEMOURS (USA) V. RECOMMANDATIONS SUR L'UTILISATION DU TUBE LORS DE LA CONCEPTION DE L'EQUIPEMENT V. RECOMMANDATIONS SUR L'UTILISATION DU TUBE LORS DE LA CONCEPTION DE L'EQUIPEMENT Les triodes et tétrodes pour radiodiffusion de THOMSON TUBES ELECTRONIQUES sont conçues et fabriquées pour offrir à I'utilisateur de hautes performances et une longue durée de vie. Quand ces tubes sont installés dans les circuits fabriqués ou approuves par THOMSON TUBES ELECTRONIQUES I'utilisateur peut avolr l'assurance qu'ils fonctionnent dans le meilleur environnement Cependant, quelle que soit la conception de ces circuits, I'utilisateur doit prendre un certain nombre de précautions et suivre les procédures de réglage r e c o m m a n d é e s s ' i l veut tirer l e s m e i l l e u r e s performances du tube. II devra consacrer le temps nécessaire pour lire soigneusement et appliquer les recommandations données dans ces paragraphes. Au cas où I'utilisateur aurait besoin d'informations complémentaires, ou s'il désire une assistance pour une installation particulière, il peut contacter THOMSON TUBES ELECTRONIQUES soit directement, soit par l'intermédiaire d'un de ses représentants. La stabilité mécanique de la cathode a toujours été un facteur important de fiabilité et de durée de vie du tube électronique. Ce facteur devient primordial dans les tubes modernes de radiodiffusion, compte tenu de la faible distance entre l a cathode et la grille de commande. Trois paramètres principaux sont à considérer : Les tubes d'émission sont munis de cathodes en tungstène thorié, à chauffage direct. La durée de vie du tube est liée en premier lieu à la température de la cathode. Celle-ci est définie non seulement par la puissance de chauffage, donc la tension de chauffage appliquée à la cathode, mais également par la puissance dissipée sur les grilles, le courant de cathode et les pertes RF. C'est la raison pour laquelle la valeur nominale de la tension de chauffage n'est pas une caractéristique générale, mais doit être définie selon les conditions d'utilisation du tube. Ces conditions doivent être transmises à THOMSON TUBES ELECTRONIQUES qui déterminera la valeur de la tension de chauffage de fonctionnement et en informera I'utilisateur. Cependant, pour prédéterminer les caractéristiques du transformateur de chauffage, nous indiquons dans nos notices la valeur approximative des tensions et c o u r a n t s de c h a u f f a g e q u a n d a u c u n a u t r e réchauffement de cathode n'intervient. En plus d'une définition correcte de la tension de chauffage, l'obtention d'une longue durée de vie de la cathode nécessite de réguler cette tension. La tolérance permise est normalement $r 2 %. II est important de noter que des tensions de chauffage soit supérieures, soit inférieures à la tension de fonctionnement sont également mauvaises pour le tube. Une surchauffe provoque une évaporation rapide du matériau émissif de la cathode tandis qu'un sous-chauffage entraîne un empoisonnement de la cathode. Dans les deux cas, la durée de vie du tube s'en trouve écourtée. Lors de l'application de la tension de chauffage, il est nécessaire non seulement de limiter l'appel de courant, compte tenu de la très faible résistance de la cathode à froid, mais également de considérer les facteurs thermiques de la cathode. Lors de l'allumage d'une cathode en cage, les fils de tungstène, à faible inertie thermique, se dilatent dès l'apparition de la tension de chauffage, alors que le support de la cathode, constitué de pièces massives, chauffe plus lentement. Ces différences de dilatation peuvent entraîner des déformations permanentes du fil de cathode donc des dérives des caractéristiques du tube, et même des arcs ou des courts-circuits intermittents entre la cathode et la grille de commande provoquant des disjonctions du tube. II est donc nécessaire de prendre des précautions pour appliquer la tension de chauffage afin de pallier ces inconvénients. La limitation du courant d'appel à l'application de la tension de chauffage est obtenue grâce à un processus basé sur un sous-chauffage permanent de la cathode à partir duquel la tension de chauffage peut être appliquée progressivement (Figure 15b) ou directement (Figure 15a). Si la tension de chauffage de fonctionnement est appliquée directement (Figure 15a), le courant crête à l'enclenchement ne doit pas dépasser la valeur maximale indiquée dans la notice du tube. Ce processus est impératif pour tous les tubes, à I'enclenchement comme à la coupure de la tension de V. RECOMMANDATIONS SUR L'UTILISAT/ON DU TUBE LORS DE LA CONCEPTION DE L'EQUIPEMENT Figure 15 - Ai plicnt~oi de /,i teiîsion de rhai~ffaged7ns le (-asd lin s-mir-cilauffngepcir?>lineni chauffage de fonctionnement Le mode d'application et de coupure est défini pour chaque tube dans la notice correspondante. En régime de sous-chauffage, on maintient en permanence une tension réduite. pour porter la cathode à unetempérature environ moitié de la température de travail. Dans ces conditions * La puissance consommée est environ égale au Ill Oème de la puissance nominale de chauffage et il n'est pas nécessaire de maintenir le refroidissement du tube (air forcé sur les connexions, circulation d'eau sur I'anode). Toutefois, des précautions doivent être prises pour assurer une libre circulation de l'eau de réfroidissement (effet thermosiphon). La température de cathode étant réduite, elle n'influence pas la durée de vie du tube. Comme auparavant, c'est lorsque la tension de chauffage de fonctionnement est appliquée que la durée de vie garantie est prise en compte ; il n'est plus nécessaire d'utiliser un transformateur de chauffage à fuite magnétique, le courant d'appel à l'application de la tension étant limité par la résistance de la cathode sous-chauffée. A noter qu'en cas de nécessité la pleine tension de chauffage peut être appliquée à partir de O à la condition que l'amplitude du courant a l'enclenchement ne dépasse pas celle définie dans la notice. I I 1 Le contacteur de chauffage doit être asservi aux sécurités de refroidissement du tube (sorties électrodes et a n o d e ) . A l a c o u p u r e d u c h a u f f a g e , une p o s t v e n t i l a t i o n d e s s o r t i e s é l e c t r o d e s et le refroidissement d'anode doivent être maintenus pendant au moins 3 minutes. Dans le cas d'un arrêt général et volontaire de l'émetteur, il est recommandé de passer par le sous-chauffage durant la période de postventilation définie précédemment (3 mn). Dans tous les cas, il est recommandé d'éviter les coupures de tension de chauffage qui provoquent des contraintes de la structure de cathode. Pour des interruptions relativement courtes de la haute tension telles les interruptions d'émetteurs OC, il est également recommandé de maintenir la tension de chauffage de fonctionnement. Y- b, L* , ""1"' & ; - v~ & ~ 2 & + & ~ ~ . z d ~ &g * a & Les hautes performances des tubes THOMSON T U B E S E L E C T R O N I Q U E S sont o b t e n u e s principalement grâce à la technologie du graphite de pyrolyse, Sur le plan électrique, les avantages essentiels sont un moindre traînage des caractéristiques, un risque d'apparition et d'évolution d'émission thermique et secondaire plus faibles et une capacité de dissipation élevée. II en résulte que la nécessité d'une faible impédance des sources d'alimentation est moins importante et la régulation plus aisée que pour les grilles de technologie classique. Dans tous les cas, un dispositif de protection contre les surintensités doit être prévu [sécurité de surintensité à coupure rapide (100 msec. max.), réglée à 1,5 fois le courant normal de fonctionnement]. De plus, il est impératif de prévoir un éclateur entre les grilles et la masse pour limiter les surtensions éventuelles pouvant apparaître sur ces électrodes. Ces éclateurs sont montés sur les connecteurs THOMSON TUBES ELECTRONIQUES décrits dans les notices particulières. Le refroidissement de l'anode par Hypervapotron offre un large coeffic~entde sécurité pour la dissipation d'anode, et les surdissipations brèves qui peuvent apparaître dans un équipement lors de réglages ou d'incidents sont facilement acceptées. En plus des consignes générales de sécurité liées à l'emploi de hautes tensions, la source d'alimentation anodique doit être asservie impérativement aux dispositifs de sécurité du tube : * Sécurités de refroidissement anode, Tension de chauffage et tension de polarisation, * Dispositifs de surintensités d'anode, de grille de commande et de grille-écran, V. RECOMMANDATIONS SUR L'UTILISATION DU TUBE LORS DE LA CONCE ->TIONDE L'EQUIPEMENT * Autres dispositifs de sécurité liés au circuit d'utilisation et aux impératifs de sécurité du personnel. Le tube doit également être protégé par un détecteur d'arc contre l'éventualité d'arcs internes et de surdissipation liés à des désadaptations éventuelles. L'installation d'un crow-bar est recommandée dans le but de dériver le courant de décharge du condensateur de filtrage de l'alimentation HT en cas de flash dans le tube. L'efficacité de ce dispositif sera vérifiée par un essai de mise en court-circuit du redresseur Pour celà, le redresseur est porté à ia tension nominale de fonctionnement et le relais de surintensité réglé à la sensibilité normale. Un court-circuit franc est alors provoqué entre les conducteurs d'aiimentation d'anode et de cathode par l'intermédiaire d'un fil de cuivre de diamètre 301100 mm et de longueur 2 cm/kV environ. Le système doit éviter la fusion du fil de cuivre. En cas de fonctionnement, le crow-bar doit couper simultanément la tension d'excitation, la tension de grille écran et la tension d'anode. L'anode peut être refroidie soit par vaporisation (Supervapotron ou HypervapotronB) avec circulation d'eau de refroidissement, soit par air forcé. Le refroidissement de I'anode par HypervapotronB est choisi quand on dépasse un niveau de puissance déterminé. La notice individuelle de chaque tube fournit des informations importantes concernant la pression et le débit de I'eau de refroidissement, auxquelles l'utilisateur doit se conformer rigoureusement. D'autre part, on doit utiliser de I'eau déminéralisée dont la résistivité doit dépasser 500 kS2.cm. Les tubes Hypervapotron@sont fournis montés dans un refroidisseur. L'entrée d'eau est marquée en bleu avec la référence "IN", la sortie d'eau en rouge avec la référence "OUT". L'eau de refroidissement doit arriver par I'entrée et I'eau de sortie chaude s'évacuer par la sortie. Pour obtenir les performances de dissipation du tube, les sécurités à prévoir sont : pression à l'entrée, débit, Les tensions doivent être appliquées en cascade dans l'ordre suivant* : tension de chauffage, tension de polarisation, tension d'anode, tension de grille-écran, tension d'excitation. A l'arrêt, il faut observer l'ordre inverse pour la coupure des différentes tensions. En cas de nécissité d'appliquer les tensions dans un ordre different, consulter THOMSON TUBES ELECTRONIQUES résistivité de I'eau, * température d'entrée et de sortie de I'eau. II est conseillé pour obtenir une exploitation stable : de prévoir une régénération de I'eau par résine de façon à maintenir la résistivité de I'eau à une valeur correcte. de filtrer I'eau de refroidissement pour éliminer toute particule solide qui pourrait obstruer le passage de I'eau de refroidissement et provoquer des surcharges locales de I'anode. II est nécessaire de prévoir le refroidissement: Refrb ~frsse/;~er7r par a1r force de I'anode du tube, * des isolants (céramiques), Le refroidissement de I'anode par air forcé est réalisé pour les tubes de dissipation anodique maximale de 20 kW. des sorties d'électrodes. Quel que soit l e mode de fonctionnement, le refroidissement doit être mis en service avant la tension de chauffage et maintenu pendant 3 minutes au moins après la coupure de cette tension. II est impératif que I'air de refroidissement soit correctement filtré pour éviter tout encrassement qui pourrait réduire le débit d'air et provoquer des surdissipations locales sur I'anode. Les sorties d'électrodes et les céramiques sont refroidies par air forcé filtré dont le flux doit être correctement canalisé pour refroidir efficacement les scellements et les sorties d'électrodes. Les connecteurs THOMSON TUBES ELECTRONIQUES répondent a cette demande et leur emploi est conseillé (voir paragraphe IV). La température des scellements céramique-métal et des céramiques ne doit pas dépasser la température maximale indiquée dans la notice particulière du tube. Une sécurité de débit d'air à l'entrée, reliée aux dispositifs de protection du tube, doit être prévue. Le filtre à air doit être nettoyé périodiquement de façon à maintenir le débit à la valeur requise. Un contrôleur de débit d'air doit être prévu et relié aux dispositifs de protection du tube. La température de I'air de refroidissement à la sortie ne doit pas dépasser la valeur limite de 100 OC. Par conséquent, une signalisation de dépassement de cette température doit être installée par l'utilisateur de façon à le prévenir en cas d'une température excessive, dont la cause peut être soit un'mauvais réglage, soit un mauvais fonctionnement. Ce dispositif doit déclencher les relais de protection du tube. V. RECOMMANDATIONS SUR L'UTILISATION DU TUBE LORS DE LA CONCEPTION DE L'EQUIPEMENT I I ( ( Les caractéristiques de refroidissement par air forcé de l'anode ainsi que des autres électrodes sont indiquées dans la notice du tube, pour le type de connecteur recommandé. La correction de perte de charge s'effectue en appliquant à la valeur de la perte de charge dans les conditions standard le coefficient correctif ya. Si la température de sortie dépasse 100 OC, on appliquera le coefficient ya yb. Elles sont définies dans les conditions standard : altitude : O température : 20 OC Caractéristiques de refroidissement sur site Choix du ventilateur Pour une installation située à une altitude supérieure à celle du niveau de la mer et à une température s u p é r i e u r e à 2 0 OC, l e s c a r a c t é r i s t i q u e s de refroidissement doivent être modifiées afin de tenir compte de la variation de la masse volumique de I'air avec l'altitude et la température. Les constructeurs de ventilateurs donnent en général les caractéristiques débitlpression dans les conditions standard (altitude 0, température ambiante 20 OC). La correction de débit s'effectue en appliquant à la valeur du débit dans les conditions standard, le coefficient Le débit restera inchangé, car le ventilateur fonctionne à vitesse constante. Par contre, la pression devra être modifiée en appliquant à nouveau les coefficients ya et éventuellement yb. II est donc nécessaire, lors du choix d'un ventilateur, de ramener aux conditions standard les caractéristiques de refroidissement trouvées pour le site d'installation. Dans les conditions standard, les caractéristiques du ventilateur seront donc : PO= pression atmosphérique au niveau de la mer. P = pression atmosphérique du lieu de l'installation. te = température d'entrée de I'air (en OC). I Ce coefficient ya modifie le débit d'air pour maintenir constante la masse d'air échangée par unité de temps. ) Dans le cas où la température de sortie d'air ( t s ) dépasse 100 OC, il est nécessaire d'appliquer un deuxième coefficient correctif yb afin d'augmenter la masse d'air échangée par unité de temps. I Qn = débit indiqué dans la notice du tube Q = débit du ventilateur y= ya ou ya x yb, suivant le cas Pression : P = Pn x 'y2 Pn = perte en charge selon la notice P = pression statique du ventilateur y= ya ou ya x yb, suivant le cas Tableau I - Valeurs de ya en fonction de la température d'entrée de I'air et I a1titi:de locale Temperature d'entrée de 1 air Alt~tudclocale au-dessus du ,ive.&ude la rner (rn) ( C) O 500 1000 1500 2000 2500 3000 3500 4000 O 0,92 0,98 1,04 1,01 1,17 1,25 1,33 1,43 1,52 1O 0,95 1,Ol 1,07 1,14 1,21 1,29 1,38 1,47 1,57 20 0,98 1,O4 1,11 1,18 1,24 1,33 1,42 1,52 1,62 25 1,OO 1,06 1,13 1,20 1,27 1,36 1,45 1,55 1,65 30 1,02 1,08 1,15 1,18 1,30 1,39 1,48 1,58 1,68 40 1,05 1,11 1,19 1,26 1,33 1,43 1,52 1,63 1,73 50 1,08 1,14 1,22 1,30 1,37* 1,47 1,57 1,67 1,78 VI. MAINTENANCE VI. MAINTENANCE Sécurité et automaticité Une bonne maintenance de l'équipement est nécessaire pour assurer une longue durée de vie du tube. Elle doit être régulièrement effectuée suivant les indications détaillées de la notice de l'émetteur. En cas d'anomalie de fonctionnement, toute défaillance des systèmes de sécurité peut entraîner une détérioration du tube par défaut de protection. Nous rappelons les points importants concernant directement le tube et qui devront être particulièrement surveillés : Vérifier : - * les séquences d'application des tensions et leur temporisation, * les dispositifs de protection contre les surintensités, * le système de coupure rapide ("crowbar"), a les sécurités concernant le refroidissement: débit, température et pression de l'agent réfrigérant (air ou eau), niveau d'eau, résistivité de I'eau. Chauffage Vérifier la tension de chauffage aux bornes du connecteur à l'aide d'un voltmètre de classe 1,5 indiquant la valeur efficace vraie (ferromagnétique, thermique ou numérique). Si cette tension n'est pas correcte, avant de la modifier, vérifier au préalable le régulateur de tension secteur et les contacts filament et filamentIcathode du connecteur. Dans le cas où le sous-chauffage permanent est installé, vérifier la tension de sous-chauffage permanent et le fonctionnement de l'installation hydraulique en thermosiphon. * Systèmes ~ ~ ~ e r v a p o t r oetnSupervapotron @ Vérifier la propreté et la qualité de I'eau, l'état des raccords antiélectrolytiques. Eiiminer les fuites d'eau éventuelles. Système Supervapotron: contrôler le niveau d'eau. Refroidissement par air Entretenir les ventilateurs. Nettoyer les filtres à air. II faut s'assurer du bon état de t'environnement immédiat du tube : * connexions et accessoires destinés au raccordement des électrodes du tube, * contacts du connecteur, * découplages, * aspect et réglage des éclateurs de protection Lors du retrait d'un tube hors service, quelle que soit sa durée de fonctionnement et avant d'installer le tube de remplacement, il faut examiner les circuits et le tube pour relever et corriger les anomalies éventuelles : les traces d'échauffement, les traces de flashes, les traces de mauvais contact. L'origine de ces anomalies peut être recherchée dans : le système de refroidissement, le positionnement du tube sur son support, * un vieillissement des contacts, * un mauvais état des condensateurs de découplage, * des déréglages accidentels des circuits, des circuits amortisseurs défectueux. VI/. TRANSPORT - MANUTENTION - STOCKAGE VII. TRANSPORT - MANUTENTION - STOCKAGE Le tube est livré dans un emballage spécialement conçu contre les chocs et les vibrations pouvant se produire dans les conditions normales de transport. Le stockage doit être réalisé dans un local sec et à l'abri de la poussière. Tous les tubes doivent être stockés en position verticale : soit dans leur emballage, Contrôle du tube dans l'emballage Dès réception, afin de déceler les dommages que le tube aurait pu subir au cours du transport, il faut, sans sortir le tube de son emballage : s'asurer du bon état de I'emballage extérieur et intérieur, dans le cas où la caisse est équipée d'un témoin de renversement, vérifier son état, vérifier la continuité du filament et l'absence de court-circuit entre électrodes à I'aide d'un ohmmètre. Pour les tubes Hypervapotron et Supervapotron, cette opération peut s'effectuer sans sortir le tube de son berceau. Contrôle du tube hors de I'ernballage Les tubes de grande puissance à refroidissement Hypervapotron et Supervapotron sont livrés montés sur une chaise support. Celle-ci est prévue pour assurer la manutention et la protection du tube pendant son stockage. Sortir l'ensemble tube de levage (figure 16). + chaise à I'aide du dispositif S'assurer que le tube ne porte pas de traces de chocs. Déplacer I'ensemble tube + chaise à I'aide d'un chariot équipé de roues pneumatiques, jusqu'à la position de service en évitant tout choc et en ayant pris soin d'éviter les obstacles. Mettre le tube en place dans l'équipement en suivant les instructions du paragraphe V11.3 "Première mise en service". Démarches à effectuer en cas de dommages Se référer aux consignes indiquées au verso du b o r d e r e a u de l i v r a i s o n joint dans l a pochette "Documents" agrafée sur l'emballage pour effectuer des réserves auprès du dernier transporteur, dans les délais exigés. soit sur leur chaise-support pour les tubes de grande puissance à refroidissement Hypervapotron ou Supervapotron, soit sur une étagère anode en bas pour les tubes de moyenne puissance refroidis à air. Les tubes sont livrés avec des protège-céramiques qui doivent rester en place pendant tout le temps du stockage. La céramique des tubes doit rester propre. Si par inadvertance la céramique était salie, i l est formellement interdit d'utiliser une toile ou un tampon métallique pour la nettoyer. Avant la livraison, chaque tube THOMSON TUBES ELECTRONIQUES a subi en usine une série complète d'essais permettant d'assurer qu'il est conforme à sa spécification. A la première mise en service d'un tube, i l est nécessaire d'effectuer les opérations suivantes: 1. Vérifier la continuité du filament et I'absence de courts-circuits entre les électrodes. 2. Mettre en place le tube à I'aide du dispositif de levage après avoir retiré le protège-céramique, en évitant tout choc. * 3. Dans le cas des Hypervapotrons, s'assurer que le sens de circulation de l'eau de refroidissement est bien respecté. 4. Appliquer la tension secteur de façon à ce que le tube soit en sous-chauffage. 5. Laisser le tube en sous-chauffage pendant au moins 30 minutes. 6. Appliquer la tension de chauffage comme spécifié dans la notice ou suivant les instructions spéciales de THOMSON TUBES ELECTRONIQUES. Après 5 minutes, vérifier la tension aux bornes du connecteur à I'aide d'un voltmètre de classe 1,5 indiquant la valeur efficace vraie (ferromagnétique, thermique ou numérique). 7. Laisser le filament allumé au moins 30 minutes, puis appliquer les autres tensions. 8. Monter progressivement la puissance en porteuse, puis appliquer progressivement la modulation. 19 INFORMATIONS - DEFINITIONS CONDITIONS DE MESURE l -- ---- - - --- -- - -- -- 1. CARACTERISTIQUES GENB RALES . œ I I r* A*- % * & & &%& "* Le débit d'eau minimal correspond à la dissipation anodique maximale pour une température de I'eau à l'entrée de 55 C et une température de I'eau à la sortie de 90 OC D'autres valeurs sont possibles à condition de ne pas dépasser 100 OC pour la température de l'eau a la sortie. E l l e est d é f i n i e par T H O M S O N T U B E S ELEcTRONIQUES pour chaque cas particulier de V : fonctionnement. Voir paragraphe recommandations sur I'utilisation du tube lors de la conceDtion de l'équipement". L a n o t i c e i n d i q u e u n e valeur a p p r o x i m a t i v e correspondant au courant de chauffage dans le cas où aucun autre réchauffement de la cathode n'intervient. Les valeurs de tension et courant de chauffage sont données à titre indicatif et uniquement pour la prédétermination du transformateur de chauffage. Les capacités interélectrodes sont mesurées dans un montage spécialement conçu pour supprimer les couplages parasites. . Le débit d'air minimal est défini dans les conditions normales : niveau de la mer et température ambiante de 20 OC. Dans le cas du refroidissement de l'anode, le débit d'air minimal indiqué correspond à la dissipation anodique maximale. Les températures maximales indiquees ne doivent être dépassées en aucun point de l'enveloppe du tube: collet, céramique, scellement céramique-métal. I t . VALEURS LIMITES ) La fiche technique indique pour les différents paramètres (tension, courant, puissance, fréquence) la valeur maximale à ne jamais dépasser pour une application donnée, en général amplificateur RF téléphonie. Deux valeurs limites ne doivent jamais être atteintes simultanément. I I ( Cour ,,nt c a t l ~ o d i q ic! ~' t e Valeur instantanée maximale du courant que la cathode peut délivrer Dissipation Puissance dégradée sous forme de chaleur dans une électrode, soit du fait du bombardement électronique. soit par le rayonnement d'autres électrodes. Ces valeurs dépendent des conditions d'utilisation. En régime porteuse : La dissipation d'anode correspond à la puissance appliquée à l'anode diminuée de la puissance HF compte non tenu des pertes. La dissipation de grille-écran correspond au produit de la tension continue par le courant continu de grille-écran. La dissipation de grille de commande correspond approximativement au produit du courant continu de grille par la tension crête de grille (la cathode étant prise comme référence). III. EXEMPLES DE FONCTIONNEMENT L'exemple de fonctionnement cité indique les performances du tube en réalisant un compromis entre les différents paramètres tension, courant, puissance, fréquence. D'autres exemples de fonctionnement peuvent être calculés, les différents paramètres devant rester à l'intérieur des valeurs limites d'utilisation indiquées. Puissance o' excitation Produit d'intermodulation Ensemble des signaux d'intermodulation produits par la combinaison de deux signaux appliqués à l'entrée de l'amplificateur. Ces deux signaux sont distants de 1100 Hz et 2450 Hz de la porteuse, leur niveau de sortie est de - 6 dB par rapport à la puissance crête. Le niveau du produit d'intermodulation est mesuré par rapport à la puissance crête. La puissance d'excitation dans le montage cathode à la masse est égale à la somme de la puissance dissipée sur la grille de commande et de la puissance fournie à la polarisation. TABLEAU il - Lcs t i i ,es de p ,issalil:e a grille poiil ddiodiffu~~ori Fréquence (MHz) TABLEAU III - C I J de pour le c h o i x des tiibes de p u i s s a n c e a iqrille pour radiodiffusion a - Tubes utilisés en amplification RF ou AF et en /ML ("PDM1')* Amplificateur Emetteur RF RF Etage d'attaque** Etage final HypervapotronB 1000 kW 1 OL 1 TH 362/TH 561 250 kW OC TH 562 TH 598 OM 100 kW TH 598 OC 100 kW Etage final Supervapotron TH 362 / TH 562 O L I OM 500 kW 300 kW OL / OM TH 362 / TH 562 AF IML Etage final 1 / TH 539 2 x TH 558 1 TH 5 3 9 i T H 558 TH 573 TH 581 TH 581rTH 555 2 x TH 532 2 x TH 532 TH 548 2 x TH 548 TH 573V 2 x TH 581V TH 581 TH 581iTH 555A IML= Impulsion Modulee en Longueur PDM = Pulse Duration Modulation Le choix du tube d attaque depend du mode de refroidissement desiré (Hypervapotronlair force) " b - Tubes util~séscomme amplificateurs BLU Emetteur Amplificateur 10 kW 5kW 1 kW TH 399 TH 376 TH 349 IV. TUBES DE MAINTENANCE THOMSON TUBES ELECTRONIQUES peut fournir également les tubes ci-après, pour lesquels des notices sont disponibles RS 2022 CL Sendetetrode Fernseh-Bildsender, Steuergitter-Schirmgitterbaçiççchaltung,negative Modulation Sendetetrode Verstarker fur Fernsehumsetzer mit gemeinsamer Bild- u n d Tonübefiragung, Steuergitter-schirmgi~erbasisschaltung, Bild-Ton-LeistungsverhaItnis 10:1 Grenzdaten Grenzdaten Frequenz Anodenspannung Gitter-2-Spannung Gitter-1-Spannung Kathodenstrom Kathodenspitzenstrom Anodenverlustleistung Gitter-2-Verlustleistung Gitter-1-Verlustleistung Frequenz Anodenspannung Gitter-2-Spannung Gitter-1-Spannung Kathodenstrom Kathodenspitzenstrom Anodenverlustleistung Gitter-2-Verlustleistung Gitter-1-Verlustleistung MHz kV1) v1) v A A kW W W Betriebsdaten Betriebsdaten 220 220 220 MHz Frequenz 18 12 MHZ~) 12 Bandbreite (-3 dB) Bandbreite (- 1,2 dB) 716+0,63~)')12+0,53~) 1O 712+0,423) kW4) MHZ~) Ausgangsleistung bei Synchronpegel 9+0,36~) 6,6+0,2g3) 6,6+0,223) kW4)') Ausgangsleistung bei Schwarzpegel Anodenspannung kV1) 5,2 4 4,8 900 800 800 Gitter-2-Spannung - 85 - 75 - 75 V1) Gitter-1-Spannung V6) Gitter-1-Spannung, Scheitelwert bei ~ynchronpegel Ug1rn SY 170 Anodenstrom bei Schwarzpegel IA sw 3,8 Gitter-2-Strom bei Schwarzpegel IGZ sw 120 Gitter-1-Strom bei Schwarzpegel IGI sw 50 Anodenspeiseleistung b.Schwarzpegel PBA SW 19,8 Treiberleistung bei Synchronpegel Pl 46+6303) Anodenverlustleistung b.Schwarzpegel PA 10,8 Gitter-2-Verlustleistung b.Schwarzpegel PGZSW 110 2 Gitter-1-Verlustleistung b.Schwarzpegel PG1 AnodenauBenwiderstand RA 570 Freauenz . ,, RS 2022 CI MHz kV v v A A kW W W Ausgangsleistung bei Synchronpegel 3-Ton-lntermodulationsabstand Anodenspannung Gitter-2-Spannung Gitter-1-Spannuna Anodenstrom beiSchwarzpegel Gitter-2-Strom bei Schwarzpegel Sitter-1-Strom bei Schwarzpegel Anodenspeiseleistung bei Schwarzpegel Treiberleistung bei Synchronpegel Ton-Treiberleistuna ,*.nodenverlustleistÜng bei Schwarzpegel AnodenauBenwiderstand MHz MHz kW1) dB2) kV al~3 UA v u ~ 2 UGl IA SW IG SW Z IG sw I PBA SW Pl SY Ton PA SW RA n Pegeldiagramm: dB Synchronpegel O 1 !r-----ï ') Spannung g q e n Kathode gemessen ') AUS der Rbhrenkapazitat cg% errechnete Bandbreite ') übergangsleistung der Steuergitter-Schirmginerbasisxhaltung 4, Kre~sverluste sind nicht berucksichtigt ') Schwarzpegel mit eingeblendeten Synchronimpulsen ): Fur Anodenstrom ohne Aussteuerung I n = 1.6 A ) Notwendige Ausgangsleistung der Treiberstufe )' Mit einer Stauchung des Synchronimpulses von etwa 5 % 1st zu rechnen Die L~near~tat beim 262 i) Leistung am Senderausgang bei 90% Kreiswirkungsgrad, ) Abstand der grd~tenIntermoduiationsstorungvom Synchronpegel innerhalb des Übertragungsbereiches WmeSSen nach der Dreiton-Methode,mit Bildtrager., Tontrager- und Seitenbandfrequenz.Die Messung erfolgt nach Pflichtenheft FTZ 176 Pfl2 der Deutxhen Bundes. post mit verzerrungsfreiern Eingangssignei: fe: -8 d ~ . fss: -16dB. f ~ -10 : dB. 3, Ffir Anodenstrom ohne Aussteuerung 1 = 2,2A. a V3) A mA mA kW W W kW Sendetetrode Sendetetrode Heizung Hochfrequenzverstarker, B-Betrieb, Kathodenbasisschaltung Heizspannung Heizstrorn Heizart: direkt Kathode: Wolfram, thoriert Grenzdaten Frequenz Anodenspannung Gitter-2-Spannung Gitter-1-Spannung Kathodenstrorn Kathodenspitzenstrorn Anodenverlustleistung Gitter-2-Verlustleistung Gitter-1-Verlustleistung Kennwerte Ernissionsstrorn bei UA= UG2= UG1= 300 V 11-Faktor des 2. Gitters bei UA= 2 kv, UG2= 600 bis 1000 V, I,=2A Steilheit bei UA= 2 kv, UG2= 800 V, IA = 1,5 bis 2,5 A KathodelGitter 1 KathodeIGitter 2 KathodeIAnode Gitter l/Gitter 2 Gitter 11Anode Gitter 2,Anode Zubehor ') Mit Schirmplatte 0 50 a in der Sdiim7gineranschluBebenegernessen. MHz kV v v A A kW W W Betriebsdaten Frequenz Ausgangsleistung Anodenspannung Gitter-2-Spannung Gitter-1-Spannung Gitter-1-Spannung, Scheitelwert Anodenstrom Gitter-2-Strorn Gitter-1-Strom Anodenspeiseleistung Treiberleistung Anodenverlustleistung Gitter-2-Verlustleistung Wirkungsgrad AnodenauBenwiderstand Kapazitaten Steckschlüssel für Rohrensicherung Steckschlüssel für Rohrensicherung Rohrensicherung Rohrensicherung Zugschalter für Rohrensicherung , Kontakffederkranze für: Fnerer KathodenanschluB AuBerer KathodenanschluB Gitter-1-Anschlu8 Giner-2-AnschluB '- t Bestell-Nr. Q81-X2109 Q81-X2110 Q81-XI 407 Q81-XI410 Q81-XI311 ') Kreisverfuste sind nicht berucksichtigt )' Fur Anodenstrom ohne Aussteuerung I,, = 0,4 A 3, Ohne Berucksichtigung einer Zh.sgtzdampfungim Gitterkreis Y MHz kW1) kV v $ rd 8,