User Manual
8347676V 2.0 Digital
Multimeter
Please read and understand all instructions before use.
Retain this manual for future reference.
3
For technical questions call: 1-800-665-8685
V 2.0 8347676
Digital
Multimeter
SPECIFICATIONS
DC Voltage Range 200m/2,000m/20/200/250V
AC Voltage Range 200/250V
DC Current Range 200µA/2000µA/20mA/200mA
AC Current Range No
Resistance 200/2,000/20k/200k/2,000k/20M Ω
Diode Test 2.8V/1mA
Continuity Yes
Decibels No
LIQUID CRYSTAL DISPLAY (LCD)
Display 3-1/2 digit LCD with max reading of 1999
Low Battery Indication shown on LCD
Negative Polarity Indication shown on LCD
Overrange Indication 1 shown on the LCD
DEVICE
CAT Rating CAT II 250V
Automatic Power Off No
Data Hold Function No
Battery Test No
Range Selection Manual
Number of Functions 6
Number of Ranges 19
Sampling Rate Approx. 3 times/sec.
Battery Details 1 x 9V battery, 6F22 or equivalent
Fuse Yes
Operation Temperature 0°C ~ 40°C, < 75%RH (Relative Humidity)
Storage Temperature -10°C ~ 50°C, < 85%RH (Relative Humidity)
Dimensions 128 x 66 x 26 mm
Weight .5 lbs (130g) including battery
Digital Multimeter
4For technical questions call: 1-800-665-8685
8347676V 2.0
ELECTRICAL SYMBOLS
Alternating Current
Direct Current
Caution, risk of danger, refer to the operating manual before use.
Caution, risk of electric shock.
Earth (ground) Terminal
Fuse
Conforms to European Union directives
The equipment is protected throughout by double insulation or reinforced insulation.
This product has been to tested to the requirements of CAN/CSA-C22.2 NO. 61010-1, second edition,
including Amendment 1, or a later version of the same standard incorporating the same level of
testing requirements.
INTRODUCTION
This meter is a compact 3 1/2–digit digital multimeter for measuring DC and AC voltage, DC current, Resistance,
Diode and Continuity.
SAFETY
The multimeter has been designed according to IEC-61010 concerning electronic measuring instruments with a
measurement category (CAT II 250V) and Pollution degree 2.
IMPORTANT SAFETY PRECAUTIONS
WARNING! Read and understand all instructions before using this tool. The operator must follow basic
precautions to reduce the risk of personal injury and/or damage to the equipment. Before allowing someone
else to use this tool, make sure they are aware of all safety information.
WARNING! The warnings, cautions and instructions discussed in this instruction manual cannot cover all
possible conditions and situations that may occur. common sense and caution are factors that cannot be built
into this product, but must be supplied by the operator.
NOTE: Keep this manual for safety warnings, precautions, operating, inspection and maintenance instructions.
WORK AREA
1. Operate in a safe work environment. Keep your work area clean and well lit.
2. Do not use in the presence of flammable gases or liquids.
3. Keep anyone not wearing the appropriate safety equipment away from the work area.
4. Minimize distractions in the work environment. Distractions can cause you to lose control of the tool.
5. Store tools properly in a safe and dry location to prevent rust or damage.
6. Always lock up tools and keep them out of the reach of children.
Digital Multimeter
5
For technical questions call: 1-800-665-8685
8347676 V 2.0
PERSONAL SAFETY
CAUTION! Wear protective equipment approved by the Canadian Standards Association (CSA) or American
National Standards Institute (ANSI) when using the tool.
1. Head Protection
a. Always wear impact safety goggles that provide front and side protection for the eyes.
b. Wear the appropriate rated dust mask or respirator when working around metal, wood and chemical
dusts or mists.
c. Wear earplugs if the power tool or work environment is noisy.
d. Wear a full-face shield if your work creates metal filings or wood chips.
e. Wear a hard hat to protect your head from falling objects.
2. Gloves
a. The gloves should provide protection based on the work materials.
b. Wear suitable gloves to reduce the effects of vibration.
3. Protective Clothing
a. Wear protective clothing designed for the work environment and tool. Examples are electrical non-
conductive clothes or clothes treated to resist corrosive liquids or materials.
4. Foot Protection
a. Steel toe footwear or steel toe caps to prevent injury from falling objects.
b. Non-skid footwear is recommended to maintain footing and balance.
5. Control the tool, personal movement and the work environment to avoid personal injury or damage to tool.
Stay alert, watch what you are doing and use your common sense.
a. Keep articles of clothing, jewelry, hair, etc., away from moving parts to avoid entanglement with a tool.
b. Do not operate any machine/tool when tired or under the influence of drugs, alcohol or medications.
c. Do not overreach when operating a tool. Proper footing and balance enables better control of a tool in
unexpected situations.
SPECIFIC SAFETY PRECAUTIONS
WARNING! Use caution when working above 30V AC rms, 42V peak, or 60V DC. Such voltages pose a
shock hazard.
To avoid possible electric shock or personal injury, follow these guidelines:
1. Do not use the meter if it is damaged. Before you use the meter, inspect the case. Pay particular attention to
the insulation surrounding the connectors.
2. Inspect the test leads for damaged insulation or exposed metal. Check the test leads for continuity. Replace
damaged test leads before you use the meter.
3. Do not use the meter if it malfunctions. Protective features may be impaired. When in doubt, have the
meter serviced.
4. Do not operate the meter around explosive gas, vapor, or dust as an electric spark may cause the gas vapour
or dust to ignite.
5. Do not apply more than the rated voltage, as marked on the meter, between terminals or between any
terminal and earth ground.
6. When measuring current, turn off power to the circuit before connecting the meter. Remember to place the
meter in series with the circuit.
7. When using the probes, keep your fingers behind the finger guards on the probes.
8. Remove the test leads from the meter before you open the battery cover or the case.
9. Do not operate the meter with the battery cover or portions of the case removed or loosened.
10. To avoid false readings, which could lead to possible electric shock or personal injury, replace the battery as
soon as the low battery indicator appears.
1 / 24 100%
La catégorie de ce document est-elle correcte?
Merci pour votre participation!

Faire une suggestion

Avez-vous trouvé des erreurs dans linterface ou les textes ? Ou savez-vous comment améliorer linterface utilisateur de StudyLib ? Nhésitez pas à envoyer vos suggestions. Cest très important pour nous !