Amplificateurs à fibre optiqueAAAAAAAA© SICK AG. Sujet à modification sans préavis.AAAAAAAA04/04/2012 11:44:59
Amplificateurs à fibre optique
Lorsque les fibres optiques LL3 sont bien connectées et le capot de protection est fermé;
1) 3) 2) Average service life 100,000 h at Ta = +25 °C
Type produit > WLL170-2P162
Numéro de
commande > 6029527
At a glance
Rapid response time (50 µs)• Switching threshold adjustment via potentiometer or teach-in via button or cable• Four different teach-in modes• Simple installation• Red or green emitter LED•
Your benefits
Reliable detection of rapid processes• Short commissioning time saves on installation costs• The optimum setting for every application due to different teach-in modes, making
the sensor customized to the specific application
•
Ideal emitted light for color or contrast detection• Fiber optics sensor with simple handling thanks to setting via potentiometer and
switch
•
Caractéristiques
Dimensions (l x H x P): 10,5 mm x 35,5 mm x 83,7 mm
Portée, maximum: 0 mm ... 1.600 mm, Système en transmission (émetteur et récepteur),
LL3-TB02 et lentille additionnelle LL3-TA01
Portée: 0 mm ... 65 mm, Système en réflexion directe, LL3-DB01
0 ... 350 mm, Système en transmission (émetteur et récepteur), LL3-
TB01 1)
Emetteur: LED 2)
Type d'émetteur lumineux: Lumière rouge visible
Longueur d'onde: 660 nm
Réglage: réglable
Réglage de sensibilité: réglable Potentiomètre, 10 tours 3)
Temps: Temporisation à la retombée
Temporisation: selectable by sliding switch: ≥40 ms
Indication: LED
Principe du capteur/de detection: Fiber-optic photoelectric sensor