Service Manual
Controller
SIGMA CONTROL 2 SCREW FLUID ≥1.1.3
9_9450 03 HCE
This manual is intendend as a guide to the installation, operation
and maintenance of your HPC Screw Compressor.
It is important from a safety point of view that the work of
installing and maintaining the compressor is undertaken by
trained personnel and should be entrusted to an
HPC Authorised Distributor
Victoria Gardens, Burgess Hill, West Sussex RH15 9RQ
Telephone: +44 (0)1444 241671 ● Fax: +44 (0)1444 247304
[email protected] ● www.hpccompressors.co.uk
Manufacturer:
KAESER KOMPRESSOREN
96410 Coburg • PO Box 2143 • GERMANY • Tel. +49-(0)9561-6400 • Fax +49-(0)9561-640130
http://www.kaeser.com
/KKW/SSC 2.03 en 02 BA-SIGMA CONTROL FLUID
/KKW/SSC 2.03 02
20130508 151238
Quick User Guide
Controller
SIGMA CONTROL 2 SCREW FLUID ≥1.1.3
9_9450 03 HCE
Manufacturer:
KAESER KOMPRESSOREN
96410 Coburg • PO Box 2143 • GERMANY • Tel. +49-(0)9561-6400 • Fax +49-(0)9561-640130
http://www.kaeser.com
1. Important settings ............................................................................................................. 1
2. Setting the contrast and the brightness ............................................................................ 2
3. Setting the display language ............................................................................................ 3
4. Logging on with Equipment Card ..................................................................................... 4
5. Adjusting the system setpoint pressure ........................................................................... 6
6. Activating the «clock» key. ............................................................................................... 7
7. Activate the «remote control» key .................................................................................... 10
8. Changing the control mode .............................................................................................. 13
9. Outputting important operational states of the machine ................................................... 14
10. Resetting maintenance interval counters ......................................................................... 15
11. Pressure relief valve checking ......................................................................................... 17
12. Checking the temperature sensor and overheating shutdown function ........................... 20
13. Interpreting operation messages ...................................................................................... 22
14. Interpreting diagnostic messages .................................................................................... 25
15. Interpreting fault messages .............................................................................................. 26
16. Interpreting warning messages ........................................................................................ 31
17. Interpreting system messages ......................................................................................... 36
Contents
9_9450 03 HCE
Quick User Guide Controller
SIGMA CONTROL 2 SCREW FLUID ≥1.1.3 i
1 / 222 100%
La catégorie de ce document est-elle correcte?
Merci pour votre participation!

Faire une suggestion

Avez-vous trouvé des erreurs dans linterface ou les textes ? Ou savez-vous comment améliorer linterface utilisateur de StudyLib ? Nhésitez pas à envoyer vos suggestions. Cest très important pour nous !