pollution degree 2 
rated surge withstand capacity 6kV 
 
control circuit: 
rated control voltage: 24V DC 
rate control feed current as per IEC 60947-1: < 40mA 
 
ambient temperature range, operation: –25°C to +70°C 
ambient temperature range, transport, storage: –40°C to +80°C 
 
feedback output (for error messages): 
simple contact, changeover switch 
 
Signal contact: 
30V AC/36V DC 
50mA continuous load current 
 
power contact: 
250V AC/DC 
6A continuous load current 
 
maximum busbar current 2500A 
 
power dissipation (min./max.): 
0.88W/2.8W 
 
degree of protection as per DIN EN 60529: IP20 
 
Safety functions: 
see type plate 
 
for further technical data, see assembly manual/operation instructions 
 
Points de raccordement 
Screw terminals (solid round, flexible, flexible with wire-end ferrule)  
0.14 - 2.5mm² / 0.5 - 0.6Nm 
The cable outlet is provided with a pluggable terminal 
 
Miscellaneous  
4 functions integrated: 
Right contactor 
Left contactor 
Motor protection relay 
EMERGENCY STOP protection up to category 3 
 
Installed width only 22.5mm