Questions for W8482-178738/A
Question 1:
Are there additional details on construction and Application of the cable?
Answer 1:
AWG size
18
# of conductors, or pairs
10
Are there shielding requirements, if so what type of shield? Tape Drain Wire? or braid?
Size? Material? Coverage?
PA/PVDF insulated; conductors color coded; overhaul tinned copper braid shield and zero
halogen jacket
Insulation material
PA/PVDF insulated
Jacket material
zero halogen jacket
Electrical characteristics, Voltage, Ampacity etc.?
600 volts
Temperature rating
150 Deg Celsius
Cable overall diameter
OD 0.409 Inch