22. Check Temperature of RRUS
>lh ru fui get temp
Normal operating temp. 40 to +50 C
23. Check RRUS for any faults (eNodeB)
>lhsh BXP_0_1 fm getfaults (Cell 1)
>lhsh BXP_1_1 fm getfaults (Cell 2)
>lhsh BXP_2_1 fm getfaults (Cell 3)
24. Check External Alarm port status and alarm slogan
>lget alarmport slogan | severity
>lst hwunit=sup-1,alarmport=[1-9]$
>lget hwunit=sup-1,alarmport=[1-9]$ alarm slogan
>get <pxoxy> - to display alarm details
>set <proxy> alarm slogan ‘cps fail’ - to set alarm text
>bl <proxy> - to block alarm port
>deb <proxy> - to deblock alarm port
eg: proxy =301
bl 301 , deb 301
25. To check and create system backup
>cvls
>cvms <cvname> <username> <comment>
>cvls
26. To Lock/Unlock MME (eNodeB)
>st mme
>bl mme
>st mme
>deb mme
>st mme
27. To Lock/Unlock eUtranCell (eNodeB)
>st fdd
>bl fdd