ASTM Standards, Sec. 15, Vol. 15.07. ASTM International, Consho-
hocken, Pa.
6. PUNTER, P.H. 1983. Measurement of human olfactory thresholds for
several groups of structurally related compounds. Chem. Senses
7:215.
7. MEILGAARD, M., G.V. CIVILLE & B.T. CARR. 1987. Sensory Evalua-
tion Techniques, Vol. 1. CRC Press, Boca Raton, Fla.
8. H.T. LAWLESS &H.HEYMANN. 1998. Sensory Evaluation of Food:
Principles and Practices. Chapman & Hall, New York, N.Y.
9. AMERICAN SOCIETY FOR TESTING &MATERIALS. 2005. Practice for
defining and calculating individual and group sensory thresholds
from forced-choice data sets of intermediate size. E1432-04, Annual
Book of ASTM Standards, Sec. 15, Vol. 15.08. ASTM International,
Conshohocken, Pa.
2170 B. Flavor Profile Analysis
1.
General Discussion
a. Principle:
1
FPA uses a group of four or five trained panel-
ists to examine the sensory characteristics of samples. Flavor
attributes are determined by tasting; odor attributes are deter-
mined by sniffing the sample. The method allows more than one
flavor, odor, or feeling (e.g., drying, burning) attribute to be
determined per sample and each attribute’s intensity to be mea-
sured. Figure 2170:1 shows the relationships among these attri-
butes and factors, as well as specific compounds that exemplify
them.
Initially, panelists record their perceptions without discussion.
Individual results are considered important, even though the
reported result is a consensus. Individual results might alert the
panel to a “new” odor or to a change. Once each individual has
made an independent assessment of a sample, the panel discusses
its findings and reaches a consensus without changing individual
results.
b. Interference: Background odors present during analysis
affect results. Analyst illness (e.g., cold or allergy) and a recent
history of eating, drinking, or smoking can diminish or otherwise
alter perception.
c. Application:
1– 4
FPA has been applied to drinking water
sources, finished drinking water, sampling points in the drinking
water treatment train, and bottled waters. It also has been used to
investigate customer complaints.
d. Quality control (QC): The QC steps considered to be an
integral part of each method are summarized in Tables 2020:I
and II.
2.
Safety
a. Samples: Some substances are health hazards when inhaled
or ingested. Do not use this method for industrial wastes or other
samples suspected to contain high concentrations of hazardous
substances. Chemically analyze suspect samples to determine
whether hazardous chemicals are present before making FPA.
Do not taste untreated drinking water unless certain that no
health threat (biological or chemical) exists.
b. Standards: Avoid human exposure to known or probable
human carcinogens. An exposure assessment of chemicals that
could be used in FPA
5
revealed that, in most cases, the levels and
duration of exposure to chemical standards for training and
calibration are well below levels of concern and should pose no
known health risks when properly used for FPA.
3.
Panel Selection and Training
Carefully select and train a group of panelists according to
procedures available from the American Water Works Associa-
tion.
6
Because four or five panelists are needed to conduct a test,
training of additional panelists may be desirable to allow for
unavailability of individuals. Because FPA includes discussions
during which panelists reach consensus on sample descriptions,
avoid including on the panel a person with a dominating per-
sonality. The opinions of a senior member or panel leader also
may have this undesired effect.
Panelists must be able to detect and recognize various odors
present. The training of panelists using odor reference standards
is important for developing a consistent terminology within the
panel and over time.
7
Trained panelists have been shown to
produce more reliable sensory data.
8
FPA requires well-trained
panelists and data interpreters. Reproducibility of results de-
pends on the panelists’ training and experience.
4.
Apparatus
3,4,7,9,10
Reserve apparatus and glassware exclusively for FPA.
a. Sample bottles: Glass, 1-L, with TFE-lined closure.
b. Containers for odor analysis:
3,4,7,10
Select containers for
odor analysis depending on panelists’ preference, sample tem-
perature, and container availability.
1) Panel preference—Plastic cups, 7-, 8-, or 16-oz (207-, 237-,
or 473-mL), disposable, are convenient. Do not use waxed-lined
paper cups. Some panels have found that plastic cups impart a
plastic and/or floral odor to samples and therefore prefer wide-
mouth, 500-mL erlenmeyer flasks with ST32 ground-glass stop-
pers. The panel should determine the acceptable, odor-free test
container (glass or plastic) most suitable to its use.
2) Temperature
3,9 –11
—If odor samples are tested at 45°C, do
not use plastic containers. If odor samples are tested at 25°C, use
the same plastic cup and sample for both odor and flavor anal-
ysis. Temperature is known to affect the intensity of an odor. For
most compounds, the odor will increase as the temperature
increases because more molecules of the odor-producing sub-
stance (odorant) will volatilize from the water sample and enter
the nose. Testing at 45°C will produce a greater odor intensity
and more likely chance of detection by panelists than testing at
25°C. (NOTE: There are a few exceptions, such as dissolved
calcium carbonate, where the compound is less volatile or more
soluble as temperature increases).
FLAVOR PROFILE ANALYSIS (2170)/Flavor Profile Analysis
2
FLAVOR PROFILE ANALYSIS (2170)/Flavor Profile Analysis