Catalogue PENTA 02-2019

Telechargé par Chaambane Mohamed Soibaha
PENTA
Moteurs CC
www.snt.tm.fr
Protection IP 54
Isolation classe F
Silencieux
Excitation à aimants permanents en ferrite haute performance Rotor à
encoches inclinées pour une meilleure linéarité
TypePuissances TensionsFormesVentilationsDimensions
Moteurs Watt (Vdc) Constructives(mm)
Couples
à la vitesse
nominale
(Nm)
3000 2000 B3 B5 B14 NaturelleAutoventil. Diamètres Longueurs
Rpm Rpm Protégée
PENTA 1S 45 0.14 24÷48 ŸŸŸ 57.8 109.5
PENTA 1M 70 0.22 ŸŸŸ 136
PENTA 1L 95 0.30 ŸŸŸ Ÿ 183.5
PENTA 4S 300 200 0.95 12÷180 ŸŸŸ Ÿ 116 197.5
PENTA 4M 600 400 1.9 24÷180 ŸŸŸ Ÿ 227.5
PENTA 4L 900 600 2.86 ŸŸŸ Ÿ 257.5
PENTA 5X 100 70 0.32 12÷180 ŸŸŸ Ÿ 83.5 144.5
PENTA 5XS 150 100 0.48 ŸŸŸ Ÿ 177.5
PENTA 5S 200 135 0.64 ŸŸŸ Ÿ 212.5
PENTA 5SL 300 200 0.96 24÷180 ŸŸŸ Ÿ 229
PENTA 5M 360 240 1.15 36÷180 ŸŸŸ Ÿ 267.5
PENTA 5L 500 335 1.6 48÷180 ŸŸŸ Ÿ 322.5
PENTA 5XA 150 100 0.48 12÷180 ŸŸŸ Ÿ 107 189.5
PENTA 5XSA 235 155 0.75 ŸŸŸ Ÿ 222.5
PENTA 5SA 300 200 0.96 24÷180 ŸŸŸ Ÿ 257.5
PENTA 5SLA 440 290 1.4 ŸŸŸ Ÿ 274
PENTA 5MA 565 375 1.8 ŸŸŸ Ÿ 312.5
PENTA 7SA 750 500 2.4 90÷180 ŸŸŸ Ÿ 116 318
PENTA 7MA 1100 750 3.5 ŸŸ Ÿ 390
PENTA 7LA 1500 1100 4.8 110÷180 ŸŸ Ÿ 462
PENTA
Cette série de moteurs à courant continu, de
puissances comprises entre 45 et 1500 watts,
née d'une attentive analyse du marché
représente le juste compromis entre prestations,
prix et qualité.
Grâce aux composants tels que les collecteurs
cuivre-argent, les charbons de durée de vie
élevée, les aimants en ferrite magnétisés et
calibrés en usine, PENTA est garant de la
compétitivité attendue dans toutes applications.
MOTEURS A COURANT CONTINU
D.C. MOTORS
SERIE
Series
PENTA 1S W
45
RPM
3000
2000
CARACTERISTIQUES GENERALES - Performance characteristics
1S 30
Pnom
[W] 45
Nnom
[rpm] 3000 2000
Cnom
[Nm] 0.143
Vnom
[V] 48 36 24
Inom
[A] 1.3 1.7 2.6
Cmax
[Nm] 0.715 0.715 0.715
Imax
[A] 6.5 8.5 13
Rarm
[Ohm] 6.3 3.33 1.33
La
TYPE MOTEUR
Motor type
PUISSANCE
Rated power
VITESSE NOMINALE
Rated speed
COUPLE NOMINAL
Rated torque
TENSION NOMINALE
Rated voltage
COURANT NOMINAL
Rated current
COUPLE MAX
Peak torque
COURANT MAX
Peak current
RESISTANCE INDUIT
Armature resistance
INDUCTANCE INDUIT
Armature inductance [mH] 9 4.95 2
Ke
[V/Krpm] 13 10 6.4
Te
[ms] 1.5 1.5 1.5
Tm
CONST.TENSION
Voltage constant
CONST.TEMPS ELEC.
Elect.time constant
CONST. TEMPS MECAN.
Mech.time constant [ms] 6 5 5
*
Seulement pour service intermittent - Only intermittent duty
VALEURS MECANIQUES - Mechanical data VALEURS ELCTRIQUES - Winding data
Jm Tt
[Kgcm²] 0.15 [min] 20
No max
[Rad/sec²] 47000 [rpm] 4000
Rl N max
[N] 196 [rpm] 3000
Al
[N] 58 F
G
[Kg] 0.95 S1
NATURELLE
T.E.N.V. FF 1
T rif
INERTIE ROTOR
Rotor inertia
ACC.MAX.THEORIQUE
Max theor. Acc.
CHARGE RADIALE MAX
Max radial load
CHARGE AXIALE MAX
Max axial load
POIDS MOTEUR
Motor weight
VENTILATION
Ventilation
INDICE DE PROTECTION
Class protection IP 54
CONST.TEMPS THERMIQUE
Thermal time constant MAX
VITESSE MAX. SANS CHARGE
Max no load speed
VITESSE MAX. AVEC CHARGE
Max load speed
CLASSE D'ISOLATION
Insulation class
FACTEUR DE SERVICE
Duty cycle
FACTEUR DE FORME
Form factor
TEMP.AMBIANTE DE REF.
Room temp.data refer. [°C] 40°
Tolérance valeurs +/-5% - Data tolerance +/-5%
MOTEURS A COURANT CONTINU
D.C. MOTORS
SERIE
Series
PENTA 1M W
70
RPM
3000
2000
CARACTERISTIQUES GENERALES - Performance characteristics
TYPE MOTEUR
Motor type 1M30
PUISSANCE Pnom
Rated power [W] 70
VITESSE NOMINALE Nnom
Rated speed [rpm] 3000 2000
COUPLE NOMINAL Cnom
Rated torque [Nm] 0.22
TENSION NOMINALE Vnom
Rated voltage [V] 48 36 24
COURANT NOMINAL Inom
Rated current [A] 1.95 2.6 3.65
Cmax
[Nm] 1.1 1.1 1.1
Imax
[A] 9.75 13 18.25
Rarm
[Ohm] 2.33 1.85 0.85
La
COUPLE MAX
Peak torque
COURANT MAX
Peak current
RESISTANCE INDUIT
Armature resistance
INDUCTANCE INDUIT
Armature inductance [mH] 4 3 1.34
Ke
[V/Krpm] 13.2 10.4 7.3
Te
[ms] 1.7 1.62 1.58
Tm
[ms] 6.5 6 6
*
VALEURS MECANIQUES - Mechanical data VALEURS ELECTRIQUES - Winding data
Jm Tt
[Kgcm²] 0.324 [min] 25
No max
[Rad/sec²] 33950 [rpm] 4000
Rl N max
[N] 196 [rpm] 3000
Al
[N] 58 F
G
[Kg] 1.3 S1
NATURELLE
T.E.N.V. FF 1
T rif
IP 54 [°C] 40°
Tolérance valeurs +/-5% - Data tolerance +/-5%
CONST.TENSION
Voltage constant
CONST.TEMPS ELEC.
Elect.time constant
CONST. TEMPS MECAN.
Mech.time constant
Seulement pour service intermittent - Only intermittent duty
INERTIE ROTOR
Rotor inertia
ACC.MAX.THEORIQUE
Max theor. Acc.
CHARGE RADIALE MAX
Max radial load
CHARGE AXIALE MAX
Max axial load
POIDS MOTEUR
Motor weight
VENTILATION
Ventilation
INDICE DE PROTECTION
Class protection
CONST.TEMPS THERMIQUE
Thermal time constant MAX
VITESSE MAX. SANS CHARGE
Max no load speed
VITESSE MAX. AVEC CHARGE
Max load speed
CLASSE D'ISOLATION
Insulation class
FACTEUR DE SERVICE
Duty cycle
FACTEUR DE FORME
Form factor
TEMP.AMBIANTE DE RREF.REF.
Room temp.data refer.
MOTEURS A COURANT CONTINU
D.C. MOTORS
SERIE
Series
PENTA 1L W
95
RPM
3000
2000
CARACTERISTIQUES GENERALES - Performance characteristics
1L 30
Pnom
[W] 95
Nnom
[rpm] 3000
Cnom
[Nm] 0.3
Vnom
[V] 48 36 24
Inom
[A] 2.5 3.4 4.9
Cmax
[Nm] 1.5 1.5 1.5
Imax
[A] 12.5 17 24.5
Rarm
[Ohm] 2.43 1.19 0.48
La
TYPE MOTEUR
Motor type
PUISSANCE
Rated power
VITESSE NOMINALE
Rated speed
COUPLE NOMINAL
Rated torque
TENSION NOMINALE
Rated voltage
COURANT NOMINAL
Rated current
COUPLE MAX
Peak torque
COURANT MAX
Peak current
RESISTANCE INDUIT
Armature resistance
INDUCTANCE INDUIT
Armature inductance [mH] 3 1.65 0.7
Ke
[V/Krpm] 13.3 10.7 7.5
Te
[ms] 1.24 1.4 1.46
Tm
[ms] 9 7 6
*
VALEURS MECANIQUES - Mechanical data VALEURS ELECTRIQUES - Winding data
Jm Tt
[Kgcm²] 0.607 [min] 30
No max
[Rad/sec²] 24711 [rpm] 4000
Rl N max
[N] 196 [rpm] 3000
Al
[N] 58 F
G
[Kg] 1,85 S1
NATURELLE
T.E.N.V. FF 1
T rif
IP 54 [°C] 40°
Tolérance valeurs +/-5% - Data tolerance +/-5%
CONST.TENSION
Voltage constant
CONST.TEMPS ELEC.
Elect.time constant
CONST. TEMPS MECAN.
Mech.time constant
Seulement pour service intermittent - Only intermittent duty
INERTIE ROTOR
Rotor inertia
ACC.MAX.THEORIQUE
Max theor. Acc.
CHARGE RADIALE MAX
Max radial load
CHARGE AXIALE MAX
Max axial load
POIDS MOTEUR
Motor weight
VENTILATION
Ventilation
INDICE DE PROTECTION
Class protection
CONST.TEMPS THERMIQUE
Thermal time constant MAX
VITESSE MAX. SANS CHARGE
Max no load speed
VITESSE MAX. AVEC CHARGE
Max load speed
CLASSE D'ISOLATION
Insulation class
FACTEUR DE SERVICE
Duty cycle
FACTEUR DE FORME
Form factor
TEMP.AMBIANTE DE RREF.REF.
Room temp.data refer.
1 / 36 100%