AXA 2400 COMPACT Convertisseur statique 120-140-180 kVA AXA POWER Membre d’ITW GSE – Leader mondial dans la fabrication d’équipements au sol pour aéronefs It’s all about connections ITW GSE ApS Smedebakken 31-33 DK-5270 Odense N Danemark Spécifications tel: +45 63 18 60 00 fax: +45 63 18 60 49 e-mail: [email protected] web: www.itwgse.com AXA 2400 Compact – 120 - 140 - 180 kVA Convertisseur fixe 1242 [48.9] 1242 [48.9] 660[26.0] 660[26.0] Dimensions Se référer aux schémas ou bien consulter www.itwgse.com 1150 [45.3] 1147[45.2] 1147[45.2] 570[22.4] 570[22.4] Type: Page: Note: Title: P 1/1 Title: ITW GSE 2400 ITW GSE 2400Main Dimensions Main Dimensions - Fixed 120-180 - Fixed kVA 120-180 kVA Drawn: 23.02.16 - RA Drawn: Approved: Scale: Approved: Revised: Scale: RA- RA1:20 (A3) RA 23.02.16 1:20 (A3) 1315 51.8 1315 1315 51.8 51.8 Revised: Rev.: - 178.120 178.1 Drg.no.: Rev.: Drg.no.: 750 29.5 1150 45.3 1150 1150 45.3 45.3 750 750 29.5 29.5 55 00. . 1133 5 0. Note: Type: Type: NOTE 3 NOTE 2 NOTE 1 Note: Note: Title: Title: NOTE 3 NOTE 2 3 NOTE NOTE NOTE 2 1 NOTE 1 Page: 1/ Type: Title: ITW GSE 2400 ITW Main Dim. - Bridge Main Mounted Dim. 120-180 Moun kV ITW GSE GSE 2400 2400 Main Dim. -- Bridge Bridge Moun Drawn: 23.02.16 - RA Les spécifications sont sujets aux changements sans notification préalable 1040 40.9 1040 1040 40.9 40.9 Note: Type: 700 700 27.6 27.6 700 27.6 980 38.6 Convertisseur sous-passerelle 13 Options standard disponibles • Input voltage 3 x 460 V 15% ou 3 x 600 V 15% • Module d’embase • Configuration pour une seule sortie • Extension des bornes de raccordement pour 2 câbles de 7 conducteurs Protections • Indice de protection: IP55, zones d’entré • Coffret de commande à distance • Fermeture des portes à clef et de sortie • Verrouillage des portes • No Break Power Transfer • Interface RS485 • Sur et sous-tension en sortie • Système “Anti-flash”pour •Surcharge avions militaires • Temperature interne élevée • Contacts secs • Erreur de tension interne • Outil de service AXA • Court-circuit en sortie • GPU inhibé • Insertion de la prise à 90% • Supervision de la tension du neutre • Supervision du courant de fuite 1250[49.2] 100[3.9] 100[3.9] 1250[49.2] Divers • MTTR: 20 minutes max. • Couleur: RAL 7035 (standard) 100[3.9] Environnement • Température de fonctionnement: -40°C à +56°C (+60°C à la charge avion) • Humidité relative: 10-100% • Niveau de bruit: <65 dB(A)@1m Surcharge • 125% pendant 600 secondes • 150% pendant 60 secondes • 200% pendant 30 secondes • 300% pendant 10 secondes • 400% pendant 1 seconde 100[3.9] Rendement • >0.93 à 180 kVA de charge PF 0.8-1 • Pertes en stand-by: 150 W • Pertes à vide: 4,4kW Normes •DFS400Specification for 400 Hz aircraft power •ISO 6858Aircraft ground support electric supplies • BS 2G 219General requirements for ground support equipment • MIL-STD-704FAircraft electric power characteristics • SAE ARP 5015Ground equipment 400 Hz ground power performance requirement • EN2282 Aerospace series characteristics of aircraft electrical supplies • EN62040-1-1General & safety requirement • EN61558-2-6General & safety requirement • EN61000-6-4 Electromagnetic compatibility Generic emission standard • EN61000-6-2Generic immunity standard • EN1915-1&2 Machinery; general safety requirements • EN12312-20 Machinery; specific safety requirements 980 980 38.6 38.6 Sortie •Puissance: : 120-140-180 kVA, PF 0.8-1 • Tension: 3 x 115/200 V • Fréquence: 400 Hz 0.001% • Facteur de puissance: 0.7 arrière à 0.95 avant • Régulation de tension: <0.5% pour charge équilibrée et déséquilibrée jusqu’à 30% • Tension transitoire: ∆U <8% et temps de rétablissement <10 ms sur 100% d’impact de charge • Contenu harmonique: <2% sur charge linéaire (typ. 1.5%) <2% sur charge non-linéaire selon la norme ISO 1540 • Facteur de crête: 1.414 3% • Modulation de tension: <1.0% • Symétrie d’angle de phase: 120° 1° sur charge équilibrée 120° 2° sur 30% de déséquilibre Poids • Unité fixe ou sous-passerelle: 650 kg Septembre 2016 Entrée • Tension: 3 x 400 V 15% • Fréquence: 50/60 Hz 5 Hz • Redresseur: Dodécaphasé compensé • Courant nominal: PF 0.8/ PF 1 120 kVA: 150 A 15% / 190A 15%* 140 kVA: 175 A 15% / 220 A 15%* 180 kVA: 230 A 15% / 285 A 15%* * Valeurs ajustées à la prochaine valeur de 5A • Distorsion de courant: 120 kVA: 9%, 140 kVA: 7%, 180 kVA: 5% • Facteur de puissance: 120 - 140 kVA: 0.99 @ charge nominale 180 kVA: 1 @ charge nominale • Courant d’appel: Aucun Drawn: Scale: Approved: Drawn: Revised: Approved: Approved: Scale: Scale: Revised: Rev.: Revised: 1:20- RA (A3) 10.06.16RA - RA 1:20 (A3) 10.06.16 - ARA RA 23.02.16 1:20 (A3) 10.06.16 - RA RA 23.02.16 - RA Drg.no.: Dimensions indiquées en mm et en (pouces) It’s all about connections It’s all about connections A 178.121 A Rev.: Rev.: